background image

39

cod: ed. 09-2021

EN

G

LI

SH

LAYOUT

Summary of Contents for BLOK-JET SILENT 1 AC200

Page 1: ...WE LOVE WHAT WE DO english BLOK JET SILENT Instruction Manual...

Page 2: ...2...

Page 3: ...ntenance compressor AC200 and AC300 15 Extraordinary maintenance compressor AC200 and AC300 16 Routine maintenance Micro Smart and Turbo Smart 17 Extraordinary maintenance Micro Smart and Turbo Smart...

Page 4: ...power 1 12 kW 1 2 kW Maximum air flow 900 l min Max vacuum with continuous operation 210 mbar Rotation speed 60 Hz 120 Hz at 50 Hz 1400 rpm at 60 Hz 1600 rpm Air tank 30 litres Air output with supply...

Page 5: ...1700 l min Max vacuum with continuous operation 210 mbar Rotation speed 70 Hz 110 Hz at 50 Hz 1400 rpm at 60 Hz 1600 rpm Air tank 45 litres Air output with supply at 5 bar 238 N l min Maximum pressur...

Page 6: ...mains IEC 417 5008 Closed disconnection from power supply mains IEC 417 5007 Alternating current IEC 417 5032 3N Three phase alternating current with neutral IEC 335 1 Earth operation IEC 417 5019 PE...

Page 7: ...operation and maintenance of your Block Jet Silent Updated manuals are available from our website www cattani it We recommend you refer to these especially for the latest safety updates This device is...

Page 8: ...ed in a clean area away from heat sources humidity and dust Temperature in the plant room must be between 5 C and 35 C Ifventilationorairconditioningisneededintheplant room the ventilation or air cond...

Page 9: ...et Silent 1 is complete with an AC200 compressor and a Micro Smart suction unit optional amalgam separator available Blok jet silent 1 is designed to service two chairs simultaneously Blok Jet Silent...

Page 10: ...ilent is installed on a lower level than the surgeries the suction piping must go down to the level of the suction unit with a couple of metres of piping laid horizontally on the same level before con...

Page 11: ...with a ventilation system with exhaustion and an inlet for air supply in order to guarantee a flow that will maintain room temperature in the range 5 C to 35 C Install the Blok Jet Silent in a clean...

Page 12: ...surgeries the suction piping must go down to the level of the suction unit with a couple of metres of piping laid horizontally on the same level before connecting with the suction unit This will remov...

Page 13: ...ommend replacing the elastic band and piston at any time throughout the life of the compressor In the cylinder air is compressed and heated up to 100 120 C it is thus necessary to pass it through the...

Page 14: ...tched off an adjustable timer will keep the suction unit on for 10 to 300 seconds OPERATION IL SEPARATORE DI AMALGAMA ISO Smart suction units can be supplied complete with our amalgam separator Idroci...

Page 15: ...ciency of fans the compressor cannot operate for long times without adequate ventilation The tap 8 located under the air tank must be opened regularly if you find there is moisture you need to call a...

Page 16: ...r capacity Every six months check the absorptions with clamp on ammeter Check for leaks in the machine in the pipework and in the chairs Check suction of each cylinder 6 or 8 bar the air drawn must no...

Page 17: ...esent contact a technician Every night aspiration of Puli Jet Plus New disinfectant solution with antiscaling agent A using Pulse Cleaner B Remove power before you go near the suction unit Place the a...

Page 18: ...sinfectant in manually tilt the machine repeatedly so that the liquid can reach all contaminated parts EXTRAORDINARY MAINTENANCE MICRO SMART AND TURBO SMART RECOMMENDED CHECKS EVERY 12 MONTHS Check ma...

Page 19: ...time a part that affects seal is disassembled Replace motor bearings and vibration dampeners If ordinary maintenance is inadequate or unsuitable products are used instruct personnel and inform the pe...

Page 20: ...will appear CONTROL MENU A2 This menu shows number of times the machine was switched on total switched on hours number of suction unit activations actual hours of suction unit use operation hours in r...

Page 21: ...h 00000 Hours operation in relation to frequency Fan Cycles 00000 Number of activations of control unit cooling fan DRIVE STATUS This menu can be accessed without a Password here you can read informat...

Page 22: ...rs menu is 0000123000 The password for the System Parameters Setup menu is 0000456000 KEYING IN AND ENTERING PASSWORD In the CATTANI S p A menu press the arrow then the arrow the display will show the...

Page 23: ...peat the same procedure to enter the password 0000456000 and access the changes of the System Parameters Setup INVERTER STATUS MENU This menu is visible without entering a password Its function is to...

Page 24: ...trifugal separator current System temperature Maximum temperature detected can be reset with code 19404 in menu drive commands Maximum detected temperature Power bus voltage Maximum bus voltage record...

Page 25: ...t Vacuum level Shows maximum vacuum level entered Press Enter to change use up down arrows Enter desired value Press Enter to confirm change I I Language You can select Italian 0 English 1 French 2 Sp...

Page 26: ...e the cursor use the arrows to enter the desired value Press Enter to confirm change All the parameters can be adjusted Minimum vacuum level only Micro Smart and Micro Smart Cube Maximum blower freque...

Page 27: ...vacuum level only Micro Smart and Micro Smart Cube Maximum blower frequency for surgery vacuum level only for Micro Smart and Micro Smart Cube Blower current limit for surgery vacuum level only Micro...

Page 28: ...28 cod ed 09 2021 Options used Enables or disables reading of amalgam sensor 0 without amalgam separator 1 with amalgam separator Commands to inverter Reserved for factory settings...

Page 29: ...dels Notes Turbo Smart produced from October 2015 from serial Number WP5xxxxx new keypad with external display removable Micro Smart produced from October 2015 from serial Number WM3xxxxx CONFIGURATIO...

Page 30: ...is complete it will show all available Wi Fi networks close to the device Select a network using the UP DOWN arrows then confirm I A couple of seconds after you have selected a network the display wi...

Page 31: ...use the arrows to scroll to WI FI Menu M5 Now the Wi Fi menu shows in S0 the non changeable IP address dynamic IP In the Wi Fi menu to control the selected network n SSID M5 S1 In Menu M5 S2 you can...

Page 32: ...1 Check that M5 S5 is set to 2 Check that DHCP is set to 1 Now press the left arrow and then EXC to back to Main menu A1 where you can see Wi Fi ON When communication with a PC is on the display will...

Page 33: ...ceeded Check mains voltage max 260V S08 40 Centrifuge short circuit Remove short circuit S09 41 Short circuit of card in centrifuge outlet Replace card S10 42 Instantaneous centrifuge current limit ex...

Page 34: ...recommend you refer to these especially for the latest safety updates Smart systems and compressors are AEE equipment thus subject to WEEE Waste Electrical and Electronic Equipment Directive regulati...

Page 35: ...rer When you need to dispose of this equipment you must contact the manufacturer and follow the system that the manufacturer has adopted to enable separate collection of the equipment after its useful...

Page 36: ...36 cod ed 09 2021 COMPRESSOR UNIT Fig A WIRING DIAGRAMS BLOK JET SILENT 1...

Page 37: ...37 cod ed 09 2021 EN G LISH MICRO SMART UNIT...

Page 38: ...38 cod ed 09 2021 AUX...

Page 39: ...39 cod ed 09 2021 EN G LISH LAYOUT...

Page 40: ...40 cod ed 09 2021 TERMINAL STRIP...

Page 41: ...41 cod ed 09 2021 EN G LISH TERMINAL STRIP...

Page 42: ...42 cod ed 09 2021 COMPRESSOR UNIT Fig B WIRING DIAGRAMS BLOK JET SILENT 2...

Page 43: ...43 cod ed 09 2021 EN G LISH TURBO SMART UNIT...

Page 44: ...44 cod ed 09 2021 AUX...

Page 45: ...45 cod ed 09 2021 EN G LISH LAYOUT...

Page 46: ...46 cod ed 09 2021 TERMINAL STRIP...

Page 47: ...47 cod ed 09 2021 EN G LISH TERMINAL STRIP...

Page 48: ...arch this enables us to apply the latest technology to all of our products and solutions We enhance performance electronic and information technology enable us to enhance the performance and reliabili...