When Blok-Jet Silent is installed on a lower level
than the surgeries, the suction piping must go
down to the level of the suction unit, with a couple
of metres of piping laid horizontally on the same
level before connecting with the suction unit. This
will remove the potential energy that the liquids
produce when flowing downward.