1280   IF A$="i" OR A$="I" THEN GOSUB *TQUP
1290   IF A$="d" OR A$="D" THEN GOSUB *TQDOWN
1300   IF A$="r" OR A$="R" THEN GOSUB *RESETN
1310   IF A$="+"           THEN GOSUB *TQINC
1320   IF A$="-"           THEN GOSUB *TQDEC
1330 '
1340 INPUT #1,RX$:IF LEFT$(RX$,1)<>"A" GOTO 970
1350 INPUT #1,RX$:IF LEFT$(RX$,1)<>"A" GOTO 970
1360 *ACTEND
1370   CLOSE
1380    END
1390 *ENTER
1400   LOCATE 6,12:INPUT "ITEM TO BE CHANGED?    ",N
1410   LOCATE 6,13:INPUT "VALUE TO BE SET    ",A$
1420    IF N=1 GOTO *WRITEAGE         'AGE
1430    IF N=2 GOTO *WRITEPLSLT       'PULSE LIMIT
1440    IF N<>3 GOTO 1510
1450       IF MODE%=1 GOTO *WRITESEX   'AEROBIC POWER
1460       IF MODE%=2 GOTO *WRITETGTQ  'MANUAL
1470       IF MODE%=3 GOTO *WRITEPROF  'HILL PROFILE
1480       IF MODE%=4 GOTO *WRITETLD   'INTERVAL
1490       IF MODE%=5 GOTO *WRITETGWATT'ISOPOWER
1500       IF MODE%=6 GOTO *WRITETGPLS 'AUTO
1510   IF N<>4 GOTO 1540
1520       IF MODE%=1 GOTO *WRITEWT    'AEROBIC POWER
1530       GOTO *WRITETGTM
1540   IF N<>5 GOTO 1570
1550       IF MODE%<>4 GOTO 1570
1560                   GOTO *WRITETGTQ
1570   LOCATE 6,12:PRINT SPC(30)
1580   LOCATE 6,12:PRINT SPC(30):GOTO *ENTER
1590   *WRITEWT
1600      IF VAL(A$)>999 OR VAL(A$)<10 THEN GOTO *OVER
1610      TX$="D"+A$:GOTO *WRITEDATA
1620   *WRITEAGE
1630      IF VAL(A$)>99  OR VAL(A$)<10 THEN GOTO *OVER
1640      TX$="A"+A$:GOTO *WRITEDATA
1650   *WRITEPLSLT
1660      IF VAL(A$)>200 OR VAL(A$)<60 THEN GOTO *OVER
1670      TX$="B"+A$:GOTO *WRITEDATA
1680   *WRITESEX
1690      IF VAL(A$)>2   OR VAL(A$)<0  THEN GOTO *OVER
1700      TX$="G"+A$:GOTO *WRITEDATA

With the EC-1500, exercise conditions (watt
value and pedal torque) can be changed while
in training.  An example is shown below.

When the training ends by pushing the
operation button on the EC-1500, the personal
computer also ends the current program.  This
status is checked twice.

The personal computer tells the EC-1500 the
contents of the change.

Inform the exercise conditions on the current
screen to the EC-1500.  This is a simple use of
the exercise condition setting command
described on page 7.

Summary of Contents for ergociser RS232C

Page 1: ...RS232C Communication Kit Instruction Manual For Model EC 1500...

Page 2: ...ion 1 1 Checking components in the package 3 1 2 Assembling RS232C communication kit 4 1 2 a Installing RS board 4 in operation unit 4 1 2 b Connecting optical cable to operation unit 4 1 2 c Connecti...

Page 3: ...ents in the package 1 Preparation Note 1 Return to the distributor the User Registration Card attached to the warrantee Answers to questions written in the inquiry slip and loading of the sample progr...

Page 4: ...e unit and the black optical cable connector is located at the rear end of the unit Secure the board with the 2 screws supplied Connect the board to the unit via the connector cable supplied K I S 0 0...

Page 5: ...2 c Connecting procedure Remove the caps A B connect the optical cable connector to the operation unit optical cable connector Fix both caps A B when it s unused Secure the optical cable on the handle...

Page 6: ...ditions and once per second when you are exercising Since the contents of the LCD differs according to setting exercise conditions and during exercise the content of data output also differs The EC 15...

Page 7: ...4 digit numeric Elapsed time Higher 2 digits minute Lower 2 digits second 6 4 digit numeric Calorie consumption 10 3 digit numeric Wattage 13 2 digit numeric Pedal torque x 10 15 3 digit numeric Pulse...

Page 8: ...character code numeric code CR code format shown in example below from an external computer setting your exercise conditions Example K6CR Selects Auto Training Character Code Function A Age up to 2 di...

Page 9: ...utton initializing the EC 1500 Before externally controlling the EC 1500 first implement the reset command When using BASIC do as follows TX r PRINT 1 TX The computer may send the code r CR LF The EC...

Page 10: ...1 Exercise Pattern Interval Training TGWATT VAL MID RX 2 3 Set wattage Isopower Training Pressing the ADV button puts the EC 1500 into exercise status As with 2 4 c sending the g CR code duplicates th...

Page 11: ...nceled in the following ways The warm up is the function that increases the pedal torque gradually for 3 minutes after starting the exercise 1 While using isopower constant wattage set the watt value...

Page 12: ...IF A A OR A a THEN GOSUB PBADV 110 IF A S OR A s THEN END 120 GOTO 70 130 PBADV 140 TX g PRINT 1 TX 150 INPUT 1 RX 160 IF RX a GOTO 150 170 RETURN Obtain data from the EC 1500 and display it on the sc...

Page 13: ...RX 21 2 260 LTPLS VAL MID RX 18 3 270 TGTM VAL MID RX 16 2 280 WEIGHT VAL MID RX 13 3 290 TGTQ VAL MID RX 11 2 10 300 PROF VAL MID RX 10 1 310 SEX VAL MID RX 9 1 320 TGPLS VAL MID RX 6 3 330 INTVL0 V...

Page 14: ...ING TGTQ 700 GOTO PEND 710 CONST 720 LOCATE 1 1 PRINT ISOPOWER TRAINING 730 LOCATE 3 2 PRINT AGE PRINT USING AGE 740 LOCATE 3 3 PRINT PULSE LIMIT PRINT USING LTPLS 750 LOCATE 3 4 PRINT SET WATTAGE PRI...

Page 15: ...ATE 3 7 PRINT PULSE RATE PRINT USING HR 1190 LOCATE 3 8 PRINT CADENCE PRINT USING CDC 1200 IF PFL 0 THEN LOCATE 42 3 PRINT PFL PRINT USING PFL 1210 IF MOU 0 THEN LOCATE 42 4 PRINT MOU PRINT USING MOU...

Page 16: ...ER 1530 GOTO WRITETGTM 1540 IF N 5 GOTO 1570 1550 IF MODE 4 GOTO 1570 1560 GOTO WRITETGTQ 1570 LOCATE 6 12 PRINT SPC 30 1580 LOCATE 6 12 PRINT SPC 30 GOTO ENTER 1590 WRITEWT 1600 IF VAL A 999 OR VAL A...

Page 17: ...TETGTM 1880 IF VAL A 99 OR VAL A 0 THEN GOTO OVER 1890 TX C A GOTO WRITEDATA 1900 WRITEDATA 1910 GOSUB DATAOUT 1920 CLS GOTO 220 1930 OVER 1940 LOCATE 6 13 PRINT SPC 30 GOTO 1410 1950 1960 1970 1980 R...

Page 18: ...30 187 B 2360 FOR I 97 TO 177 STEP 10 LINE 25 I 30 I NEXT I 2370 FOR I 60 TO 600 STEP 30 LINE I 187 I 190 NEXT I 2390 LOCATE 0 23 PRINT 60 2400 LOCATE 0 18 PRINT 100 2410 LOCATE 0 13 PRINT 140 2420 RE...