688018-218 en-nl ma 2020
12
CLEANING AND MAINTENANCE:
Step 1: After usage, the device must first be switched OFF, after which you must remove the
plug from the socket. Always do this in the order described to prevent short circuit
or other possible dangers.
Step 2: Wait until the device has cooled down completely.
Step 3: Push on the black cap of the tap and turn it a quarter to let the oil run out of the
basin.
Step 4: Remove the grid (nr. 3).
Step 5: Clean the in- and outside of the device with a wet cloth and a small amount of
cleaning-detergent and then dry it thoroughly. Do not use benzine, thinner, scouring
brush or polishing powder to clean the induction fryer.
Pay attention!
Do not rinse the device with water. (Don’t wash it by using the tap).
This could cause damage to the device and could therefore lead to dangerous
situations.
Never clean the device with a stainless steel brush.
This causes scratches and damages the device.
Use a vacuum cleaner to (gently) remove dirt and debris from the air-ventilation-grille.
Always store the fryer inside and keep it dry.
ERROR CODES
Display information
for control panel
Description
Possible cause
Possible solution
HEATING light
flashing once
(again and again)
Insulated Gate Bi-
polar Transistor on
the Printed Circuit
Board Is overhea-
ted. Buzzer alarms.
Check ventilation
slots on dirt
and grease
and make sure
there is enough
space around the
appliance.
Switch the appliance OFF,
let it cool DOWN. |
Switch appliance on again.
Contact your supplier if it happens
frequently.
HEATING light
flashing 2 times
(again and again)
Heating without oil
in the tank.
No oil in the tank. Fill the tank with oil.
HEATING light
flashing 3 times
repeatedly
Voltage higher than
265V, lower than
135V
Electrical
installation could
be disordered or
damaged.
Make sure an electrician will check it.
HEATING light
flashing 4 times
repeatedly
Temperature sensor
in the oil tank is
either shorted or
opened. Buzzer
alarms
Temperature sensor
is defective
Appliance IS overheated. Let it cool
down. Contact your supplier if it happens
frequently.