EXTERNAL POWER SUPPLY 

An external power input  terminal, J5, is used for the external power supply input.  However, remember never to connect any 
supply to these inputs so long as you have JP4, JP5, JP6 and JP7 installed.  In case you want to use the external supply as 
an input you must remove these 4 jumpers in order not to cause any conflict with the bus voltages.  These jumpers are, 
however, independent from each other.  For instance if you would want to bring in only a +5V from the external supply and 
continue to use the bus voltages for +12V, -12V, and +3.3V, you would only need to remove JP5.  The list below identifies 
which jumper is for which supply: 
 
JP4 =  -12V 
JP5 =   +5V 
JP6 =  +12V 
JP7 =  +3.3V 
 
JP7 1-2 installed 

è

 3.3V from on-board regulator 

JP7 2-3 installed 

è

 3.3V from the bus 

JP7 not installed 

è

 3.3V from the external supply 

 
The following diagram indicates the interconnection of the Unit-Under-Test voltages to the bus voltages and the external 
voltages: 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+5VE 

 

 

 

ON-OFF  

 

5V out to UUT 

 

 

 

Circuitry  

           

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VIO to UUT 

 

 

 

 

 

 

 

 

 

 

 

 

 

JP5 

 

 

 

 

JP10 

 

  ON-OFF 

 

 

 

 

  Circuitry 

 

 

 

 

    

+5V from the bus   

 

+VIO  from bus  

 

 

As indicated, there will be conflict in case the external supply is connected while the jumper is still in place.  This circuit is 
repeated for each of the 4 voltages . 
If you are using external power supplies do not forget to connect the Ground (GND) signals between the system and the 
supply.  If your external power supply outputs are not isolated, make sure the ground of the PC (containing the extender 
board) and the ground of the power supply are at the same voltage phase/level with respect to a common point, before 
connecting the GND signal. 
 

If making current measurements in +5V, be sure to remove JP10 if the VIO and +5V on your 
board are on the same voltage plane. 

 

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Summary of Contents for PCIBX32-X

Page 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Page 2: ...n 2 3 February2003 90 Great Oaks Blvd Suite 102 San Jose CA 95119 Tel 408 365 3846 Fax 408 365 3847 Email support catalyst ent com www getcatalyst com P N 400 0062 003 Artisan Technology Group Quality...

Page 3: ...X32 3 PCIBX64 5 PCIBX64 3 7 MECHANICAL DIMENSIONS 7 REGISTERS 8 PROGRAMMING GUIDE 10 READ WRITE ROUTINES 14 EXAMPLE ON OFF SOFTWARE CONTROL 15 SAMPLE CODE 15 AC CHARACTERISTICS 15 HOT SWAPPING UTILITI...

Page 4: ...ue SW commands or continue to use the switch to turn the power to the extender Off and back On In addition to Hot Swapping the main voltages and signals the PCIBX cards have the following features 1 S...

Page 5: ...iguration registers This software is available free of charge For an overview of these software packages see the Hot Swapping Utilities section of this manual ON OFF To insert or remove any Unit Under...

Page 6: ...ing Guide CURRENT LIMIT CIRCUITRY Red LEDs when illuminated indicate a short or a very low voltage Green LEDs when illuminated indicate voltages at their corresponding outputs 5V 12V 3 3Vare electroni...

Page 7: ...rnal supply The following diagram indicates the interconnection of the Unit Under Test voltages to the bus voltages and the external voltages 5VE ON OFF 5V out to UUT Circuitry VIO to UUT JP5 JP10 ON...

Page 8: ...ltage condition D15 12V has a short or low voltage condition D14 3 3V has a short or low voltage condition D16 5V has a short or low voltage condition 5V 3 3 V Translation PCIBX is capable of allowing...

Page 9: ...5V source is from the external input JP6 Installed 12V source is from the system Not Installed 12V source is from the external input JP7 Installed 1 2 3 3V to UUT is from On board source Installed 2 3...

Page 10: ...gation Delay Less than 500 Pico seconds from the PC bus to the UUT The switch propagation delay is rated at only 250 Pico seconds On Off Controls SPST switch on board or the system parallel port Outpu...

Page 11: ...1 Enables power switches to be programmed PCI UUT Voltages 64 e4 W R D0 0 On 5V 12V 12V and 3 3V D0 1 Off After turning the extender on and before start using the UUT or starting any test program a w...

Page 12: ...tected D2 1 32 operation established PCIBX64 Only D3 0 33 MHz enabled slot D3 1 66 MHz enabled slot D4 0 DUT not fully asserted D4 1 DUT asserted 32 64 status bit clear 77 f7 W 0x0 To clear status reg...

Page 13: ...0 DUT not fully asserted D4 1 DUT asserted 4 Clear 32 64 bit status Use the set Address routine to set address DUT 1 0x77 DUT 2 0xf7 Use write routine to write 0x0 5 To Turn on or off any Voltages Gl...

Page 14: ...e turning any voltages on or off Use the Set Address routine to set address DUT 1 0x66 DUT2 0xe6 use write routine to write 0x0 11 3 3V Aux Down Use the Set Address routine to set address DUT 1 0x66 D...

Page 15: ...dress routine to set address DUT 1 0x67 DUT2 0xe7 use write routine to write D 7 0 Signal to Convert Read 0X08 2 5V Reference 0X09 12V UUT 0X0A 5V UUT 0X0B 3 3V UUT 0X0C 5V Aux 0X0D Current 5V 0X0E Cu...

Page 16: ...tages and currents in Volts and Amps except 12V voltage Read Data decimal 5 75 2 5 4096 for 12V voltage only 15 Select 5V ramp Use the Set Address routine to set address DUT 1 0x7c DUT2 0xfc use write...

Page 17: ...I card Address register outp 0x37a 0xd6 Wait 100 us minimum Reset the AS and DS signals outp 0x37a 0xde Set the port to read mode outp 0x37a 0xff Read Register and display I inp 0x378 Reset the AS and...

Page 18: ...6 strobe address o 37a de return strobe o 378 00 set data to turn the board on o 37a dc strobe data o 37a de return strobe Commands to turn the PCIBXOFF o 37a de return strobe o 378 64 set address for...

Page 19: ...se refer to the PCIUD document located on our website http www getcatalyst comon the Documents page 2 PCIUW This Windows program allows the users of Windows 95 98 ME and Windows NT 2000 XP to read sav...

Page 20: ...operly by executing your application 5 If the UUT is working properly you can proceed using the software provided in this package please see the section on Operating Instructions for PCIUW or PCIUD 6...

Page 21: ...UUT power Easy automation of the power up and power down cycles through software control Minimizes the extender board connector wear out This fixture is designed for a 6 high PC Chassis the user must...

Page 22: ...oller or other Bridge Chips If it does install a 22 uF Capacitor between Pin 3 of U13 and GND This capacitor will slow down the time between when the 5V goes high and the time the Chip enable is drive...

Page 23: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Reviews: