6.16 Install spacer (19) small diameter down
into inlet valve (20).
6.18 Install washer (17) with curved surface
down on to spring (18).
6.17 Install spring (18) over spacer (19) and
on to inlet valve (20).
6.20 Assemble the discharge valve as follows:
Insert spring (26) into retainer (27).
6.21 Place valve (25) cupped side over the
spring (26).
6.19 Apply Loctite®242® to M6 threads on
plunger rod. Thread nut (16) onto M6
threads of plunger rod and torque to
25 in-lbs.
Loctite and 242 are registered trademarks of the Henkle Corporation
6.22 Place tapered side of seat (24) towards
retainer (27) and snap into place.
6.23 Lubricate and install o-ring (23) to seat
(24). Repeat for second valve assembly.
6.24 Press discharge valve assembly (30)
into top hole with retainer facing into
crankcase body (1) until flush with
cylinder head surface.