1. SAFETY INSTRUCTIONS

 

 

In its conception, specification of parts and production, this machine is in compliance with regulation in force, namely 

the European Standards (EN) and internationals (IEC). 

There are applicable the European Directives “Electromagnetic compatibility” and “Low voltage”, as well as the standards IEC 

60974-1 / EN 60974-1 and IEC 60974-10 / EN 60974-10. 

 

1.1 ELECTROMAGNETIC COMPATIBILITY

 

 

The user is responsible for installing and using the arc welding equipment according to the manufacturer’s instructions. 

If electromagnetic disturbances are detected, then it shall be the responsibility of the user of the arc welding equipment to 

resolve the situation with the technical assistance of the manufacturer. In some cases this action may be as simple as connect to 

earth the welding circuit. In other cases it could involve constructing electromagnetic screens enclosing the welding power 

source and the work complete with associated input filters. In all cases, electromagnetic disturbances shall be reduced to the 

minimum to avoid troubles. 

Before installing arc welding equipment the user shall make an assessment of potential electromagnetic problems in 

the surrounding area. The following shall be taken into account: 

a) Supply cables, control cables, signaling and telephone cables, above, below and adjacent to the arc welding equipment; 

b) Radio and television transmitters and receivers; 

c) Computer and other control equipment; 

d) Safety critical equipment, e.g. guarding of industrial equipment; 

e) The health of the people around, e.g. the use of pacemakers and hearing aids; 

f) Equipment used for calibration or measurement; 

g) The immunity of other equipment in the environment. The user shall ensure that other equipment being used in the 

environment is compatible. This may require additional protection measures; 

h) The hour of day when welding or other activities are to be carried out. 

 

1.1.1 Methods of reducing emissions

 

 

Connection to mains

 

 

Arc welding equipment should be connected to the input supply system according to the manufacturer’s 

recommendations. If interference occurs, it may be necessary to take additional precautions such as filtering of the supply 

system. Consideration should be given to shielding the supply cable of permanently installed arc welding equipment, in 

metallic conduit or equivalent. Shielding should be electrically continuous throughout its length. The shielding should be 

connected to the welding power source so that good electrical contact is maintained between the conduit and the welding 

power source enclosure. 

 

Welding cables

 

 

The welding cables should be kept as short as possible and should be positioned close together, running at or close to 

the floor level. 

 

Equipotent bonding

 

 

Bonding of all metallic components in the welding installation and adjacent to it should be considered. However, 

metallic components bonded to the work piece will increase the risk that the operator could receive an electric shock by 

touching these metallic components and the electrode at the same time. The operator should be insulated from all such bonded 

metallic components. 

 

Work piece earth connection

 

 

When the work piece is not bonded to earth for electrical safety, nor connected to earth because of its size and 

position, e.g. ships hull or building steelwork, a connection bonding the work piece to earth may reduce emissions in some, but 

not all instances. Care should be taken to prevent the earthling of the work piece increasing the risk of injury to users, or 

damage to other electrical equipment. Where necessary, the connection of the work piece to earth should be made by a direct 

connection to the work piece, but in some countries where direct connection is not permitted, the bonding should be achieved by 

suitable capacitance, selected according to national regulations. 

Summary of Contents for CastoMatec RCD 400

Page 1: ...GB USER S GUIDE F GUIDE DE L UTILISATEUR RCD 400 RCD 600 RCD 850 Ed 05 2012...

Page 2: ...RIC SCHEMA 10 6 SPARE PARTS LIST 11 7 MAINTENANCE 13 F La machine que vous venez d acqu rir a b n fici dans sa r alisation de la grande exp rience du fabricant dans la conception et la fabrication de...

Page 3: ...protection measures h The hour of day when welding or other activities are to be carried out 1 1 1 Methods of reducing emissions Connection to mains Arc welding equipment should be connected to the i...

Page 4: ...e all interlinked in one which must be grounded in the same conditions Unless very special care have been taken do not proceed to any arc welding or cutting in conductive enclosures whether it is a co...

Page 5: ...gher degree of filters if welding is performed in locations which are not well lighted 1 3 2 Risk of internal injuries Gases and fumes Gases and fumes produced during the welding process can be danger...

Page 6: ...cally or remotely at distance They allow welding of all kinds of electrodes 400 model until 6 mm diameter and 600 and 850 models until 8 mm diameter and TIG for mild steels stainless steels copper and...

Page 7: ...Un Electrode diameter mm 8 0 Current plug V VA 230 VAC 2200 VA Weight Kg 230 Dimensions cm 78 x 67 x 98 Technical data Un Electrode diameter mm 8 0 Current plug V VA 230 VAC 2200 VA Weight Kg 270 Dime...

Page 8: ...lights on indicating that the welding set is under voltage 1 Select MMA in MMA TIG 2T TIG 4T selector indicator lights on 2 Select the desired position in Local Remote selection button Adjust current...

Page 9: ...ff if there is no default The red indicator lights on indicating that the welding set is under voltage 1 Select ARC AIR in MMA ARC AIR Mod 600 and 850 TIG selector indicator lights on 2 Adjust Local R...

Page 10: ...J3 J2 nen enzco co wmwmww J 0 f f f f f J Q CDCDroCDCD CDO 0 o o en en 1 1 r r l lllllill A1 Main switch Cl Print circuit F Socket remote control ln Inductance M Fan PT Tiristors bridge J z z 3 Tl Tl...

Page 11: ...11 6 SPARE PARTS LIST Caster wheel model...

Page 12: ...e coil 10 Rectifier bridge 11 Ammeter Voltmeter 12 Plastic panel 13 Quick plug 14 Fan 15 Current plug 16 Transformer 17 230 400V switch 18 Input cable 19 Cable holder 20 Wheel tubular poles model 21 C...

Page 13: ...le supply cables conduits connectors extension cables sockets on the power source ground clamp and electrode holder These connections and mobile accessories are marked according to standards if consis...

Page 14: ...aquelle les mat riels de soudage et autres quipements fonctionnent 1 1 1 M thodes de r duction des missions Alimentation L quipement de soudage doit tre connect au r seau selon les indications du cons...

Page 15: ...point lui m me mis la terre dans les m mes conditions Vous interdirez sauf prendre des mesures tr s sp ciales que vous appliquerez avec une grande s v rit de soudage et de coupage l arc dans des ence...

Page 16: ...i dessus correspondent aux domaines o les proc d s de soudages ne sont pas habituellement utilis s dans las pratiques actuelle de la soudure NOTE Il faut utiliser un chelon plus lev si le soudage est...

Page 17: ...t le laiton Sur le panneau arri re tous les mod les sont quip s d une prise monophas e de 230 V 2200 VA pour l alimentation d outillage portatif lectrique l conomiseur de gaz ou le g n rateur de haute...

Page 18: ...Diametre d electrode mm 8 0 Prise du courant V VA 230 VAC 2200 VA Poids Kg 230 Dimensions cm 78 x 67 x 98 Caracteristiques Un Diametre d electrode mm 8 0 Prise du courant V VA 230 VAC 2200 VA Poids Kg...

Page 19: ...r indiquer l alimentation du poste 1 S lection mode de soudage MMA Enfoncer la touche de s lection MMA ARC AIR mod 600 et 850 TIG pour MMA voyant s allume 2 Enfoncer la touche de s lection commande Lo...

Page 20: ...s aucun d faut Le voyant rouge s allume pour indiquer l alimentation du poste 1 Enfoncer la touche de s lection MMA ARC AIR mod 600 et 850 TIG pour ARC AIR voyant s allume 2 Enfoncer la touche de s le...

Page 21: ...l Dl Dl Dl Dl CD CD CD CD CD IIIilIIIil IfIll1 1 o o UJ UJ 1 1 A1 Interrupteur general Cl Circuite imprim F Ficha commande distance ln lndutance M Ventilateur S Voyant N SH Shunt T Transformateur T1 T...

Page 22: ...22 6 NOMENCLATURE Mod le avec 4 roues...

Page 23: ...oltm tre 12 Panneau de polycarbonate 13 Raccord rapide femelle 14 Ventilateur 15 Prise de courant 16 Transformateur 17 Commutateur 230 400V 18 C ble d alimentation 19 Serre c bles 20 Roue mod le avec...

Page 24: ...gulier Tous les 6 mois ou plus fr quemment si n cessaire utilisation intensive dans un local tr s poussi reux D poser le capot et souffler l appareil l air sec V rifier le bon serrage des connexions...

Reviews: