7
Warning:
The rated power of the mounting device is indicated on the back of the unit panel. Please
check the voltage. All work carried out on the electrical installation may be outsourced only to qualified
personnel.
The manufacturer is not responsible in case of non-compliance with the rules of conduct contained in
the instructions.
Note:
Keep your hands and other parts of your body away from moving parts of the tire assembly.
Do not wear pendants, bracelets or loose clothes when using the device.
Obliterated or missing labels should be replaced immediately with new ones.
Keep the labels in the operator's sight.
11. How the device is used.
The control devices are shown in
Figure 3,
they consist of:
- clamping bracket (
11
), used to lock and unlock the vertical arm (
10
) and the horizontal arm(
12
).
Lifting head 2-3 mm.
- Column tilt pedal (
7
), allowing you to tilt the column(
6
) backwards.
- jaw clamp pedal (
5
), allowing you to close and open four jaws (
4
) on the Stage.
- rim break pedal (
3
), used to control the paw of the carer (
14
)
- rotation pedal (
1
), allowing you to rotate theStage (
2
) clockwise and vice versa.
12. Preparing for use.
After folding the device, make sure it's working.
Fig. 6
1)
Press the rotation pedal (
1, Fig. 3
), the Stage (
2,
Fig. 3
) should startrotating clockwise. Release the
pedal, the table should start rotating
counterclockwise.
2)
Lower the break arm with your hands (
8, Fig. 3
)
and then press thepedal (
3, Fig. 3
) the break arm
should close.
3)
Press down on the pedal (
5, Fig. 3
) to the end to
open the four jaws: press again, the barks should
be at rest: repeat the action severaltimes, the
barks should close.
4)
Press the pedal (
7, Fig. 3
), the column will tilt to the resting position. Repeat the action , the
column returns to the working position.
6
5)
Press the button on the handle (
11, Fig. 3
), horizontal arm(
12, Fig. 3
) and vertical arm(
10,
Fig. 3
), willlatch. Meanwhile, the head will automatically lift about 2-3mm from the rim edge:
repeat the action,the horizontal arm (
12, Fig. 3
) and the vertical arm (
10, Fig. 3
) will be
released.
6)
Press the air meter trigger to release the air flow from the nozzle.
13. Instructions for use
Fig. 7