Castelmonte HELIOS PELLET Operating And Maintenance Handbook Download Page 18

c.2 Radio control

The stove is controlled through the remote control or in case of emergency by the small rear

“emergency panel”.

The remote control is used to adjust all of the operating parameters, set the timer, but

especially to continuously monitor the ambient temperature. The keyboard of the remote

control is equipped with rubber keys, the upper directly accessible, while the lower keys are

hidden by the door.

                                                            Remote radio control with open door

Pressing the keys the display lights and the lighting stops after 10 seconds.

 

To operate the remote control 2 batteries 1.5 V (AAA) are required.

It is advisable to keep spare batteries at home.

The remote control performs the function of room thermostat and therefore it is

recommended to keep it in the room where the stove is insta

lled

Keep the remote control away from sources of direct heat and water. It is advisable to keep it

out of reach of children

 Note: Do not press the Key (key 14) on the remote control (see legend on next page) because
its use will be managed exclusively by the authorized service centers.

Summary of Contents for HELIOS PELLET

Page 1: ...00 HELIOS PELLET HELIOS PELLET HELIOS PELLET HELIOS PELLET OPERATING AND MAINTENANCE HANDBOOK...

Page 2: ...S c 1 Initial warnings c 2 Radio control c 3 Emergency panel c 4 Turning ON from remote control c 5 Setting currrent time and day c 6 Turning OFF from remote control c 7 Operating mode c 8 Warm air ve...

Page 3: ...working season of the stove While seasonally using the stove in case of bad draught of unfavorable weather conditions temperature less than 0 C verify if the flue is perfectly insulated and not obstr...

Page 4: ...the glass when the stove reaches its temperature be cautious before touching the stove Do not leave unattended children close to the stove when it is on because each hot surface can cause severe burn...

Page 5: ...et weight 141 kg Pellet tank capacity 17 kg Pellet consumption min max 0 9 2 3 kg h Run mtime min max 7 4 18 9 h Electric power at the ignition 300 W Electric power at the operation 100 W Fuel Pellet...

Page 6: ...nly small amounts of ash after use NB The use of pellet of very low quality or of different material as fuel for your stove damages the device and causes the cessation of warranty and manufacturer lia...

Page 7: ...ich is the only one authorized to start up the stove The expected 24 months guarantee is valid exclusively when the installation and test are performed by an Authorized Castelmonte Service Center We w...

Page 8: ...ey by inserting the pitchforks in the proper slots of the wooden packing In order to position the stove inside a room a good general rule is to lay the stove on the floor gently with maximum caution a...

Page 9: ...le covering materials such as wood panelled walls wallpapers L 20 cm min B 20 cm min R 20 cm min In case of presence of delicate objects such as furniture curtains sofas considerably increase the dist...

Page 10: ...ng the technical characteristics that must have smoke evacuation system The internal section of the smoke evacuation system the materials in which it is built The homogeneity of the section The height...

Page 11: ...echanical stress heat the action of products of combustion and their condensates It must not have obstructions along its entire length It must be properly insulated in order to avoid the formation of...

Page 12: ...connection pipe must receive exhaust of a single stove It is absolutely forbidden to discharge fumes without proper chimney It is important avoid bottlenecks that obstruct the exit of smoke YES NO YES...

Page 13: ...verify that the chimney cap is properly operating extracting the fumes the chimney cap must be constructed in such a way as to prevent the penetration of rain snow or foreign bodies into the flue as w...

Page 14: ...radiant effect and a sudden reduction of the fume temperature Assembly the exhaust channel in such a way to ensure it is airtight using suitable materials that can withstand the product of combustion...

Page 15: ...E EXTERNAL AIR INTAKE EXTERNAL AIR INTAKE INSPECTION T CONNNECTION INSPECTION T CONNNECTION INSULATED FLUE INSPECTION T CONNNECTION BRICK CHIMNEY INSPECTION T CONNECTION sloping 3 4 Min 1 5 2 m Max 2...

Page 16: ...luding Connection to the smoke evacuation system The electrical connections Presence and efficiency of the air intake The test is considered positive only after that all phases of the operation will b...

Page 17: ...ment Use only original spare parts recommended by the manufacturer Keep always the stove clean to ensure good efficiency and a correct operation At the first start there might be a slight amount of sm...

Page 18: ...rol with open door Pressing the keys the display lights and the lighting stops after 10 seconds To operate the remote control 2 batteries 1 5 V AAA are required It is advisable to keep spare batteries...

Page 19: ...ded in 5 areas Area 1 days of the week Area 2 icon that indicates the data transmission Area 3 clocks This area is split in 2 parts clock ON that indicates the current time and clock OFF that indicate...

Page 20: ...rvice centers In case of accidental pressures the panel exits the view state within 24 seconds 2 Self learning remote control It allows the receiver of the emergency panel of self learning code transm...

Page 21: ...cy panel will display identification codes to 3 digits c 4 Turning ON from remote control After you have connected the power cord to the rear part of the stove turn the main switch to the position I T...

Page 22: ...ing state to turn off the stove during the initial stage you must wait for the completion of this phase In case of accidental switching off the stove can be restarted only after a completion of the pr...

Page 23: ...ntrol the only active keys are the or 3 and 5 key allowing you to increase decrease the temperature to be set The temperature value is incremented decremented by 1 C from a minimum of 5 C to a maximum...

Page 24: ...or the first time first check that the set temperature in the automatic mode is higher than the ambient temperature after activate Ecostop and perform adjustment to the desired temperature If the remo...

Page 25: ...e With this option the stove will automatically select the fan speed based on the power of the flame The system continuosly monitors the fan speed against the power of the flame and it will never allo...

Page 26: ...to a maximum of 23 hours and 50 minutes from the current time Pressing the OK key 10 you save the shutdown time that stay displayed The Sleep icon remains on At 10 seconds after the last press of a bu...

Page 27: ...he 9 and 12 keys cycles through preset daily programs identified with numbers from 00 to 50 and pressing the OK key 10key will save the setting day the symbol of the day begins to flash the daily prof...

Page 28: ...P99 Stove ON Stove OFF WEEKLY PROGRAM N HOUR DAYS 0 00 1 00 2 00 3 00 4 00 5 00 6 00 7 00 8 00 9 00 10 00 11 00 12 00 13 00 14 00 15 00 16 00 17 00 18 00 19 00 20 00 21 00 22 00 23 00 Mon Fri P01 Sat...

Page 29: ...00 6 00 7 00 8 00 9 00 10 00 11 00 12 00 13 00 14 00 15 00 16 00 17 00 18 00 19 00 20 00 21 00 22 00 23 00 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30...

Page 30: ...s available MIN Power 1 MED Power 3 MAX Power 5 To switch off the stove you have to turn the selector 4 to the OFF position Both red and green LEDs indicate the operating condition of the stove c 14 S...

Page 31: ...if the trouble remains Check the flue and the quality of the pellet being used A05 Pressostat alarm Check obstructions in the flue and in the flue pipes Check that stove door is close A06 N A A07 N A...

Page 32: ...ore the proper operation in the presence of the A18 alarm you should contact Authorized Service Center NOTE In case of automatic shutdown the stove can be restarted only after the completion of the pr...

Page 33: ...in the brazier are open and clean Check the efficiency of the door gaskets Perform cleaning of the flue and combustion chamber 2 change of the pellet 3 Contact Authorized Service Center Ignition feilu...

Page 34: ...rect positioning can ensure ignition and optimal operation of the stove Remove ash from the fire compartment and empty the ash drawer Remove the brazier housing see picture clean inside and remove any...

Page 35: ...outside of the stove flues Clean the inside of the firebox and brazier and descaling brazier housing Cleaning of fans mechanical verification Cleaning inspection and descaling of the spark plug and i...

Page 36: ...e the battery compartment of the remote control On the remote control is highlighted icon that indicates the need for replacement For Operation requires 2 batteries 1 5 V AAA It is advisable to keep s...

Page 37: ...k plug Emergency panel Smoke sensor Main switch Smoke pressostat Temperature sensor Pellet feeder gearmotor Alarm overheating pellet tank Alarm overheating firebox Smoke extractor Ambient air fan Rpm...

Page 38: ...NOTES...

Page 39: ...NOTES...

Page 40: ...Castelmonte Srl si riserva il diritto di apportare modifiche alla produzione senza preavviso alcuno Castelmonte srl Nerviano MI Italy Tel 39 0331 58 00 64 r a Fax 39 0331 58 00 67 www castelmonte com...

Reviews: