background image

16

17

4) AUTOMATIC TmT

  

Set the spot liquid dispensing time with timer (Tm) and the time between one spot 

and the next (TmT) 

The button is pressed once so that the machine dispenses spots automatically, 

press the button again once to stop dispensing the spots.

The 

Tm

 and 

TmT

 modes interact: to use the automatic 

TmT

 mode, first set the 

desired dispensing time in the 

Tm

 mode.

Tm mode

: Set the spot dispensing time, check millilitres by means of a graded 

container. 

Operate on buttons       and       to change the quantity of liquid 

Then switch to the TmT mode to set the automation times.

TmT mode

: Press the button so that the machine automatically dispenses the 

spots at regular intervals, calculated in tenths of seconds. 

In order to change the intervals between one spot and another, therefore the dis-

tance between one spot and the next during treatment, operate on buttons        

and  

See the tables attached to this manual.

5) MAN (manual)

This allows opening and closing the solenoid valve in order to spray the product 

as desired. Press the button to dispense the product continuously, press it again to 

stop. This function is normally used to wash the entire system after work.

2) AUTOMATIC mlt

Set the millilitres (ml) of the spot and the time between one spot and the next (mlt) 

The button is pressed once so that the machine dispenses spots automatically, 

press the button again once to stop dispensing the spots.

The 

ml

 and 

mlt

 modes interact: to use the automatic 

mlt

 mode, first set the de-

sired millilitres in the 

ml

 mode.

ml mode

: Set the millilitres to be dispensed. 

Operate on buttons      and      to change the quantity of liquid  

Then switch to the mlt mode to set the automation times.

mlt mode

: Press the button so that the machine automatically dispenses the 

spots at regular intervals, calculated in tenths of seconds. 

In order to change the intervals between one spot and another, therefore the dis-

tance between one spot and the next during treatment, operate on buttons        

and 

See the tables attached to this manual.

3) SEMIAUTOMATIC Tm

 

Every time the button is pressed, a spot is dispensed

Tm mode

: press the button to dispense the product of a period of time between 

0.05 and 2.50 seconds as set by the operator, by pressing the buttons      and  

Technical information

B

mlt 02.6

tm 1.23

tmt 02.6

man

Summary of Contents for Doctor Fly 120

Page 1: ...Doctor Fly 120 Quello che mancava Operation and maintenance manual version 6 2016 ...

Page 2: ...page 14 Doctor Fly 120 technical data page 19 Doctor Fly 120 wiring diagram page 21 13 pin socket plug instructions page 22 Faults and troubleshooting page 24 B C Operating instructions Installation and connections page 25 Starting and operating page 26 Adjustments page 27 Maintenance page 28 Catalogue Doctor Fly 120 complete page 29 Tank unit 120 page 30 Komandante page 31 Button page 31 Complian...

Page 3: ...ise when reading this manual contact the nearest Casotti authorised dealer or Casotti Irroratori directly Safety standards The user must thoroughly read the technical operating instructions pertaining to proper use of the machine This manual must be read before operating the machine and must always be at hand to be referred to Safety information must be completed with the specific operating and ma...

Page 4: ...l personnel involved in operating the equipment is properly formed Doctor Fly 120 is a sprayer of substances that are harmful for humans Therefore the operator must remain on the moving vehicle on the opposite side of the dispensing area of the pesticide without allowing any other person to be in the vicinity of the sprayer The safety distance varies according to the operating pressure as a refere...

Page 5: ...g suitably authorised and qualified personnel to use the lift truck While waiting for installation the package must be stored indoor in a dry area to prevent damage to the box and to the machine If the package needs to be stored outdoors cover it with a waterproof cover so that dust rain and humidity may not cause damage Warranty The terms and conditions of the warranty are determined as follows u...

Page 6: ...antity of liquid to be sprayed with every single spray with a precision up to the millimetre also setting an automation for automatic operation Doctor Fly 120 is small in size and this facilitates its use in areas where travelling is difficult Due to its full draft tank it is suited also for hilly areas Doctor Fly 120 is used to spray pesticides on the foliage of olive and fruit trees If Doctor Fl...

Page 7: ...opening and closing D Flow meter to manage the quantity of product to be dispensed E Rod with manually adjustable jet F 13 pin power socket Komandante I Cable with 12V power supply plug L Tank unit power supply cable with 13 pin plug see page 22 M Socket for spot actuation button O Display P Main switch ON OFF Q Mode button R Button S Button T Plant counter button it counts the number of sprays th...

Page 8: ...f the solenoid valves measures the quantity of dispenses liquid and sends this data to Komandante in the cabin Komandante automatically closes the solenoid valve when the desired quantity is reached Warning when setting the RH LH selector switch in the RHLH position both sides at the same time the dose set on Komandante is divided between the two nozzles Operation of Komandante operator panel The ...

Page 9: ...ense the product continuously press it again to stop This function is normally used to wash the entire system after work 2 AUTOMATIC mlt Set the millilitres ml of the spot and the time between one spot and the next mlt The button is pressed once so that the machine dispenses spots automatically press the button again once to stop dispensing the spots The ml and mlt modes interact to use the automa...

Page 10: ... steel internal gears AISI 303 STAINLESS steel sleeve EN 10088 3 FPM Viton NBR EPDM silicone seal materials Doctor Fly 120 technical data Solenoid valve Dimensions 70 x 80 x h 120 cm Weight 60 kg Flow rate per minute 25 l min Pressure 25 bar Operating pressure 3 to 8 bar Voltage 12 V Current absorption 8 A Noise level Less than 70 dB 2 CENTRAL CORE Technical information B 6 FC8 Aquilotto This does...

Page 11: ... Doctor Fly 120 wiring diagram Technical information B CABLE WITH PLUG CONNECTION VIA PTO TO THE PUMP TERM IN AL W ITH 13 PIN PLUG 1 2 V P O W E R S U P P L Y C A B L E W I T H P L U G KOMANDANTE IN CABIN BUTTON IN CABIN TANK UNIT ...

Page 12: ...22 23 13 pin socket plug instructions INSERT THE PLUG ACCORDING TO THE FITTING AND TURN CLOCKWISE TO SECURE IT TOOL TO REMOVE THE PLUG WHEN NECESSARY Follow the instructions in the table below ...

Page 13: ...ircuit is not properly cleaned between one use and the next the flow meter could become clogged and stop working Flush clean water through the circuit for a few minutes set MAN on Komandante the try to spray the pre set quantity again Komandante set to ml 4 If the flow meter is severely clogged and flushing it with water does not solve the issue flush the circuit with water and degreasing detergen...

Page 14: ...pot and the next On Komandante when in mlt or TmT mode operate on buttons and to respectively increase or decrease the duration of the pause between one spot and the next with precision up to one tenth of a second Starting Open the cover Pour the mixture into the tank Tighten the cover Start Komandante with the relevant pull switch on the side Select the mode and perform the relevant settings In o...

Page 15: ...ode and press the button until clean water comes out Drain residual water with the tank drain cap Cleaning the solenoid valve See the solenoid valve specification and components on page 19 Since the solenoid valve may become clogged remove and clean it thoroughly any time it is necessary To do so remove the fitted solenoid 1 unscrew the bulb 2 by 90 until it clicks using a pair of pliers then thor...

Page 16: ...30 31 Tank unit 120 Code DO31 Catalogue D Komandante Button Code K2010 Code DO9 ...

Page 17: ... and maintenance manual Original of the declaration of conformity to provisions of Machinery Directive 2006 42 EC The machine is manufactured to be included in a machinery or to be assembled together with other machinery to form a complex assembly that operates as one The machine cannot be commissioned until the machinery it is going to be included into and of which it will become a component is i...

Page 18: ...s of Machinery Directive 2006 42 EC Name and address of the person authorised to compile the Technical File Casotti Elisa Via Cerreto 8 1 43035 Felino Parma Italy The signatory of this document is Mrs Casotti Elisa who has full legal authority to represent Casotti Irroratori within the European Union Felino on the Casotti Elisa Doctor Fly 120 operation and maintenance manual version 6 2016 The inf...

Page 19: ...otti Irroratori Via Cerreto 10 43035 Felino Parma Italy Phone 39 0521831311 Fax 39 0521 336892 info casotti it Quello che mancava www casotti it facebook com CasottiIrroratori youtube com IrroratoriCasotti ...

Reviews: