— 3 —
1-3. Interface
1-3-1. C In-line
1)
In-line connection diagram
The maximum in-line cable length and the maximum connection unit will be varied by the
in-line communication speed as shown below list.
[In-line cable wiring]
Total cable length is max. A m
ECR
PC
ECR
ECR
Terminater(100 ohms)
Terminater(100 ohms)
In-line Communication speed
Maximum
Maximum cable length
(Band rate)
connection unit
A (m)
1.25 M bps
8
86
625 K bps
12
200
312.5 K bps
20
430
156.25 K bps
32
890
2)
Connection:
Multi drop
3)
Terminator:
100
Ω
4)
We recommend that PC is a terminal set.
5)
If PC is not the terminal set, FG(PC side) should not connect with cable ground.
Then to make 10 cm of cable which is non-terminal resist.
1-3-2. KP In-line
1)
BPS speed:
1,200bps,
2,400bps,
4,800bps,
9,600bps,
19,200bps
2)
Connection:
T branch
3)
Terminator:
Open
4)
We recommend that PC is a terminal set.
5)
If PC is not the terminal set, FG(PC side) should not connect with cable ground.
Then to make a 10 cm of non-terminal resistor and to connect it in this case.
6)
Dip switch