background image

                                                                                                 
 

 

34 

 

5.3  Mechanical Performances 

 

5.3.1  DT-X10 

 
Table 5.13 

Item Specification 

Condition 

Resistance to drop impact (height) 

In bare condition 

120 cm 

Onto concrete, three times on each of the 6 sides and 
4 corners. 

In individual carton 
box 

70 cm or less 

 

In master carton box  50 cm or less 

Onto concrete, one time on each of the 6 sides, 1 
corner, 3 edges. 

Resistance to vibration 

0.15 G or less 

10 to 55 Hz 
In X,Y, and Z directions 
Reciprocally for 30 minutes 

Resistance to vibration  
(in package) 

1.5 G or less 

10 to 55 Hz 
In X,Y, and Z directions 
Reciprocally for 30 minutes 

         
                                                                           

 

 

 

   

5.3.2   DT-160IOE/DT-169CHGE 

 
Table 5.14 

Item Specification  Condition 

Resistance to vibration 

0.15 G or less 

10 to 55 Hz 
In X,Y, and Z directions 
Reciprocally for 30 minutes 

Resistance to vibration  
(in package) 

1.5 G or less 

10 to 55 Hz 
In X,Y, and Z directions 
Reciprocally for 30 minutes 

Resistance to impact   

In bare condition 

70 cm 

One time for 6 faces onto concrete surface

In individual carton box 

70 cm or less 

 

In master carton box 

50 cm or less 

One time for 6 faces, 1 corner and 3 edges

 
 

5.3.3  DT-5022CHG

 

 
Table 5.15 

Item Specification  Condition 

Resistance to vibration 

1 G or less 

10 to 55 Hz 
In X,Y, and Z directions 
Reciprocally for 30 minutes 

Resistance to vibration  
(in package) 

2 G or less 

10 to 55 Hz 
In X,Y, and Z directions 
Reciprocally for 15 minutes 

Resistance to impact   

In bare condition 

75 cm 

6 faces, 1 corner and 3 edges 

 

In individual carton box 

75 cm or less 

6 faces, 1 corner and 3 edges 

Summary of Contents for DT-X10 series

Page 1: ...DT X10 Series Laser Scanner Integrated Models Hardware Manual Version 1 01 CASIO Computer Co Ltd Copyright 2005 All rights reserved August 2005...

Page 2: ...DT 5025LBAT 25 2 9 DT 894CFU CF Card Extension Unit 25 Chapter 3 Interfaces 26 3 1 DT X10 26 Chapter 4 Product IdentificationAnd Reference Numbers 28 Chapter 5 Quality References 29 5 1 Environment P...

Page 3: ...tered trademarks of their respectiveowners No part of this document may be produced or transmittedin any formor byany means electronic or mechanical foranypurpose withouttheexpress written permission...

Page 4: ...4 Editorial Record Manual Version no Date edited Page Content 1 00 November 2003 Original version 1 01 August 2005 All The descriptionabout new model DT X10M10RC2 is added...

Page 5: ...0E DT X10M10RC and DT X10M10RC2 handheld terminals with built in IntelPXA255 Application Processor 1D bar code scan engineand diverseWireless LAN communications viaBluetooth IEEE802 11bWireless LANand...

Page 6: ...DialupNetwork FileTransfer Security function WEP128 bits Superb scanning capability With the installed bar code scanengine it is possible to read industrial standard bar codes Scanning performance is...

Page 7: ...MPC 577ADP ACAdaptor Output 16DCV 2 8A AC100VtoAC230V AD S42120AE ACAdaptor Output 12DCV 3 0A AC100VtoAC230V DT 5023BAT BatteryPack Lithium ion rechargeable battery 1 550 mAh DT 5025LBAT Large capacit...

Page 8: ...mpanied in each individual carton box of the models Table 1 3 Accessory Product Q ty Remark Large capacityBatteryPack Cover 1 For DT 5025LBAT PCCardRemover 2 Stylus 1 Wriststrap 1 User s Guide 1 in En...

Page 9: ...ccess Point Label printer etc PCMCIA Bluetooth module Ver1 1 Class2 Label printer etc Communication card cover DT 892TCV DT 893LTCV DT X10 CF card extension unit DT 894CFU AC adaptor AD S42120AE Car P...

Page 10: ...key This keycan beassigned with any function available 8 Numeric keys Use these keysto input numbers and letters 9 Execute key Press to register an inputvalue and advance to the next step These keysca...

Page 11: ...er key Press to perform a bar code read operation This isalso pressed tocancel a full reset 20 LTrigger key Press to perform a bar code read operation This isalso pressed tocancel a full reset 21 Wris...

Page 12: ...12 1 3 1 DT 167CHGE Car Mounted Battery Charger View Fig 1 3 PowerIndicatorLamp PowerContacts PowerSwitch Carplugcodejack Removebutton...

Page 13: ...equires installation of a specialdriver on the PC 3 RS 422 port This port is used when connecting to another Bridge Satellite Cradle 4 ACadaptorjack Connect theACadaptorhere 5 Wall mount unit fastenin...

Page 14: ...ridge Satellite Cradles This lamp indicates whether thesystemis operating normally Regardless of whether ornot a HandheldTerminal is mounted this lamp indicates the system status and whether or not a...

Page 15: ...15 1 3 3 DT 5022CHG Rapid Battery Charger Fig 1 5 Top Left Right Bottom Views Charge status indicators Dual charger connection terminals ACadaptorjack Connection attachments Battery pack compartments...

Page 16: ...16 1 3 4 DT 5023BAT DT 5025LBAT Battery Packs Views Fig 1 6 DT 5023BAT DT 5025LBAT Bottom Bottom Side Side Left Left Top Top Charge Power supply terminals Charge Power supplyterminals...

Page 17: ...PC A UPC E EAN NW7 Code39 Code93 Code128 EAN128 Interleaved2of5 MSI IATA ITF Display Displaydevice 3 5 inch2 wayTFTcolorLCD No ofdots 240 w x320 h Dotpitch 0 22 w x0 22 h mm Backlight LED Displayfontt...

Page 18: ...0 1 1 Approx 4H DT 5023BAT Batterylife Approx 10H DT 5025LBAT Assuming wait scanning wirelessLAN operation13 3 4 DT 5025LBAT 2weeks Memorybackupby Lithium ionbattery pack DT 5023BAT 1week Seenote3 10...

Page 19: ...lors 2 Red green Display StatusLED Displaycontent Systemoperationstatus LINE Comm status DATA Powerstatus POWER RefertoChapter2 6 StatusIndication WithLEDs DIPswitch 8switches Seepage22 Input Detectio...

Page 20: ...ismountedonthecharger Display StatusLED Flashinginred PowerisONbuttheterminalisnotmountedonthecharger Input DetectionswitchforDT X10 Pushswitch Inputvoltage DC12V 24V 5 DC12V Approx 1 400mA Consumptio...

Page 21: ...ptor AD S42120AE Output voltage DC5V 10 Output current 2 500 mA maximum Charge method Constant voltage With current curb function Approx 2 5hours ForDT 5023BAT Charge time Approx 5 0hours ForDT 5025LB...

Page 22: ...e Not used Always set to OFF Not used Always set to OFF Host computer interface Interface 6 RS 232C OFF USB ON Termination setting for daisy chain connection Termination 5 At middle OFF No chain Termi...

Page 23: ...em LEDOFF Linestatusindicator LINE Communicationisinprogresswith DT X10 LEDONingreen 2 colorLED 2 7 DT 5022CHG Rapid Battery Charger Basic Block Table 2 9 Item Specification Remark Basicfunction Recha...

Page 24: ...ionvoltage DC4 0 0 1V Inputvoltage DC8 0to20V Timer Chargetimer standbymode 90 minutes Chargetimer standard mode 720 minutes Tricklechargetimer 120 minutes Chargehour DT 5023BAT Approx 2 5hours for1pa...

Page 25: ...0to40 C 1 6A 0to50 C Chargevoltage 4 2 0 05V 4 2 0 05V Chargehour standard mode 2 5hours 5 0hours Chargewith DT 5022CHG Weight 50gorless 100gorless Dimensions 57 L x37 W x12 8 H mm 57 L x37 W x24 H mm...

Page 26: ...I O CE1 O CE1 O 7 32 CE2 O CE2 O A10 O A10 O 8 33 VS1 I VS1 I OE O OE O 9 34 IORD O IORD O A09 O A09 O 10 35 IOWR O IOWR O A08 O A08 O 11 36 WE O WE O A07 O A07 O 12 37 RDY BSY I IOREQ I VCC P VCC P 1...

Page 27: ...y Item Specification Remark Condition DT 5023BAT DT 5025LBAT Ratedvoltage 3 7V Ratedcapacity 1 550 mAh DT 5023BAT 3 400 mAh DT 5025LBAT Approx 8hours DT 5023BAT Approx 18hours DT 5025LBAT IncaseofWait...

Page 28: ...which is reservedbythe manufacturer Seethefigurebelowfor each meaning 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Production month of the year 1 to 9 A B C Production year last digit only Ex 1 represents the...

Page 29: ...on 10 to 80 RH No condensation Humidity Non operation 5 to 90 RH No condensation Storage in carton box Temperature 10 to 50 C Humidity 90 RHorless Nocondensation Dustandwater splashproof IP54 level co...

Page 30: ...0 to 50 C When batteryis not charged Temperature Storage 10 to 55 C Operation 20 to 90 RH No condensation Humidity Storage 20 to 90 RH No condensation Storage in carton box Temperature 10 to 55 C Humi...

Page 31: ...mperature Non operation 20 to 70 C Operation 10 to 80 RH No condensation Humidity Storage 5 to 90 RH No condensation Storage in carton box Temperature 10 to 50 C Humidity 90 RHorless Nocondensation Du...

Page 32: ...prox 1 6A Whilesupplyingpowerortransmittingdata Voltage DC12V 5 Anti staticstrength Malfunction 6 KV Destruction 12 KV 150pF 330ohm Linenoisestrength Malfunction 1 000V Pulsewidth 5KHz Burstcycle 300m...

Page 33: ...larity 5 2 5 DT 5023BAT DT 5025LBAT Table 5 11 Item Specification Remark Anti staticstrength Malfunction 5KV Destruction 10KV ESD method 250pF 100ohm Probe Fingertype Polarity 5 2 6 DT 894CFU CF Card...

Page 34: ...Resistance to vibration 0 15 G or less 10 to 55 Hz In X Y and Z directions Reciprocally for 30 minutes Resistancetovibration in package 1 5 G or less 10 to 55 Hz In X Y and Z directions Reciprocally f...

Page 35: ...it Table 5 17 Item Specification Condition Resistance to vibration 0 15 G or less 10 to 55 Hz In X Y and Z directions Reciprocally for 30 minutes The unit is installed on theDT X10 With the extension...

Page 36: ...urs Electronicpartsonly MTBF WirelessLAN module 27 000hours Charginganddischargingcycle ofbatterypack 300timesor more ApplicabletoDT 5023BAT DT 5025LBAT 5 4 2 DT 160IOE DT 169CHGE Table 5 19 Item Spec...

Page 37: ...le 5 21 Standard Model EN301 489 17 EMI EMS EN60950 EN60825 Class2 EN300 328 2 DT X10M10E Yes Yes Yes Yes DT X10M10RC Yes Yes Yes Yes DT X10M10RC2 Yes Yes Yes Yes 5 5 2 DT 160IOE DT 169CHGE Table 5 22...

Page 38: ...inish of external shape 20 0 1A Insulator P V C Sheath Finishofexternalshape 4 3 0 1mm Conductance resistance 0 12 morless Characteristics Insulationresistance 50M or more Pinlayoutdiagramofcableforch...

Page 39: ...3P by Sanyo Industrial Co Pin layout diagramofcable for chain connection and long distance pin to pin straight twist pair connection Wiring Pin no Signal Pin no Signal 1 IRS 1 ORS 2 IRS 2 ORS 3 ISD 3...

Page 40: ...hasnotbeeninserted practice systemoperation that maintains a backup to avoid loss of data due to consumption of thebatteries Precautions for long term storage over one week Priortolong termstorage ove...

Page 41: ...pt to charge the battery close to a fire in direct sunlight or in a car parked in the sun Aheated battery pack will trigger the internal hazard protection means to stop the charging function Or the pr...

Page 42: ...orelectricshock mayoccur Ifthereis an abnormality immediatelyturn off the Power switch and be sure to remove the batteries and unplug the AC adaptor fromthe wall outlet then contact aCASIO distributor...

Page 43: ...r should the container be tippedover a fire or electric shock mayresult 3 Do not unplug theAC adaptor by pulling the power cable byhand The cable maybe damaged causing a fire or electric shock Always...

Page 44: ...ead to unexpected loss or alteration of data Place ofinstallation 1 Do not place the DT X10 in an environment with a significant amount of moisture or dust Otherwise a fireorelectric shock mayoccur 2...

Reviews: