background image

4. CONTROL PANEL OPERATION 

 

 

 
1. SPEED: Select one of three speeds to run the unit at.. 
SP1:  1,300 - 1,500 notes/min  SP2: 1,000 – 1,200 notes/min  SP3: 700 – 900 notes/min 

 

2. PRESET: Provides selection of preset batch amounts. When you press this key, the values change in the following order 
100 

 50 

 25 

 20 

 10 

 0 

 100… 

You can also select any size batch using the numeric keys. 

 

3. ADD: Provides a cumulative total of all counted notes. 
Every time the unit completes a count, the cumulative total is shown on the count display 
To use this function, press ADD key before placing notes onto hopper. 
*Any batch that is interrupted or has an error, is not counted towards the total. 

 

4. LEVEL: Density level key, 4 levels 
AUTO 

 I 

 II 

 III 

 AUTO… 

 

5. NUMERIC KEYS: Allows for batch selection using totals other than pre-programmed batches. 
 
6. CLEAR: Clears the display for batch counting or when an error is displayed. 

 
 

Summary of Contents for MSB-30

Page 1: ...MSB 30 Currency Counter Instruction Manual...

Page 2: ...2 SAFETY PRECAUTIONS Page 3 3 APPEARANCE Page 3 4 CONTROL PANEL OPERATION Page 4 5 SPECIFICATIONS Page 6 6 ACCESSORIES AND OPTIONS Page 6 7 ERROR CODES Page 7 8 DAILY CARE Page 8 Specifications are su...

Page 3: ...this unit c When replacing fuse use only the same type and rated fuse Using a different type or higher rated fuse can result in a fire hazard d Do not touch notes or put your hands near the stacker wh...

Page 4: ...ing the numeric keys 3 ADD Provides a cumulative total of all counted notes Every time the unit completes a count the cumulative total is shown on the count display To use this function press ADD key...

Page 5: ...Auto level Unit scans first note and sets the correct density level Use for new and or very lightly printed notes Use for medium colored notes when levels I and III do not work Use for solid and darkl...

Page 6: ...ER CAPACITY 200 notes POWER SOURCE Universal AC 90 240V 50 60Hz POWER CONSUMPTION 35W 6 ACCESSORIES AND OPTIONS Accessories Power cord operation manual dust cover dust brush Options External display R...

Page 7: ...unt bundle Make sure notes are stacked evenly and rerun bundle E CF Counterfeit note detected by UV sensor Remove suspect note and recount bundle E FC Counterfeit note detected by magnetic sensor Remo...

Page 8: ...ecount the bundle In case of any error please reset the count by removing all notes and pressing the CLEAR key as the actual count if continued may be incorrect 8 DAILY CARE You may clean the unit usi...