14 / 38
a.
Coins jam in validator
1.
Open the main door and leave aside
2.
Raise the upper cover and put the anti-falling locker
3.
If in this state you can accede to the reason of the incidence
(coin jammed, clip,
screw, etc…) remove it and close again the device.
4.
If it is not seen with evidence the jam reason, it might be and internal validator
jams.
5.
Unplug the CashKeeper from the powerline (220V) and the USB connection
6.
Disconnect the connection with the isolation screen and the side connector.
7.
Remove the lugs that fix the metal isolation screen.
8.
With the lugs out, lift the isolation screen to liberate the validator of his anchor
and, with care, move the set slightly forward and extract it.
9.
Verify inside the output channels located at the base of the validator
10.
If in this state you can accede to the reason of the incidence
coin jammed, clip,
screw, etc…) remove it and replace and reconnect the device.
11.
Otherwise, follow the next procedure…
12.
Release the metallic screen fixations of the validator, opening the side legs of the
screen (handle it with care)
13.
With a screwdriver help (star), remove the two screws that hold the disc lid of the
validator.
7
6
7
6