CSN-80V User manual
55
HEX
:
1D
28
6b pL pH cn fn m d1…dk
Function
Store QR code data to QR code data buffer
Parameter
range
4 ≤ (pL + pH×256 ) ≤ 7092 (0 ≤ pL ≤ 255, 0 ≤ pH ≤ 28)
cn=49
fn=80
m=48
0 ≤ d ≤ 255
k = (pL + pH×256 ) - 3
Default
No
Notes
Store two-dimensional code data (d1...dk) to data buffer.
((pL + pH×256) - 3) bytes is processed as a graphic data after the m (d1...
dk).
Example
None
Printing QR code
Name
Printing QR code
Code
ASCII
:
GS (
k
pL pH cn fn m
DEC
:
29
40
107 pL pH cn fn m
HEX
:
1D 28
6b pL pH cn fn m
Function
Printing QR code
Parameter
range
pL=3, pH=0
cn=49
fn=81
m=48
Default
None
Notes
Printing QR code.
Users must consider QR code graph space. (The space of up and down,
left and right of QR code graph is specified in the specification.)
Example
1b 40
1d 28 6b 03 00 31 43 03
1d 28 6b 03 00 31 45 30
1d 28 6b 06 00 31 50 30 41 42 43
1b 61 01
1d 28 6b 03 00 31 52 30
1d 28 6b 03 00 31 51 30
Setting QR code graph information
Name
Setting QR code graph information
Code
ASCII
:
GS (
k
pL pH cn fn m
DEC
:
29
40
107 pL pH cn fn m
HEX
:
1D 28
6b pL pH cn fn m