Dust Detective             

                                                                                                

 

 

 
 

 

 

System Overview 

The complete system (Part number 206107A) would require the purchase of the static air sampling enclosure 
(Part number 206200D), plus the following additional items:- 

 

Microdust Pro, 

 

Apex2ISPlus air sampling pump and charger 

 

Pre weighed GFA filters 

 if gravimetric analysis is required 

 

PUF filters 

 if size selection of dust fractions is required 

 
The key component to this accessory is the sampling inlet can utilise Polyurethane Foam (PUF) for size-
selective filter techniques. If used without the PUF filters then total dust levels are sampled. Size-selective 
filters were originally developed for operation in the Conical Inhalable Sampler (CIS) as detailed within the 
Health and Safety Executive publication MDHS 14/4. The foam filter specifications and dimensions determine 
the desired aerosol size selection characteristics and eliminate particle sizes greater than PM

10,

 PM

2.5 

or 

Respirable (4um) as appropriate. The larger particles become trapped and collect within the foam matrix, 
whilst al

l particles below these “cut

-

off points” pass through the PUF filters and enter the measurement 

chamber, where the 
real time mass 
concentration is 
established. 

After passing through 
the Microdust Pro, 
particulate matter is 
deposited on a 37mm 
filter which may be 
used for gravimetric or 
chemical analysis. 

Remember however, 
although the Dust 
Detective system has 
been designed to 
monitor particulate 
fraction concentrations 
in a variety of 
environments, it does 
have some operating 
limitations. The 
instrument is not 
designed to operate 
continuously out of doors for long periods over approximately 13 hours. 

Figure 2 

Summary of Contents for Dust-Detective

Page 1: ...L Static Air Sampling Enclosure HB3341 07 November 2018 Casella Regent House Wolseley Road Kempston Bedford MK42 7JY T 44 0 1234 844 100 F 44 0 1234 841 490 E info casellasolutions com www casellasolu...

Page 2: ...ation 7 Storage of PUF Filters 7 PUF Filter Adaptor 8 Inserting Removing PUF Filters 8 Collection Filter Cassette 9 Starting measurements 10 Checking Probe Span 10 Sampling Pump 10 Service 11 Technica...

Page 3: ...d of by placing in a fire or incinerator nor must they be punctured crushed or otherwise mutilated or opened up in any way Disposal must be in accordance to local environmental legislation Ensure the...

Page 4: ...from those in the manual If there are any questions please contact Casella for clarification Casella makes continual advancements in its products and services We therefore reserve the right to make ch...

Page 5: ...ssory provides a simple solution for short to medium term fixed area monitoring with the Microdust Pro and Apex2 sampling pumps and is designed specifically for use in indoor applications but some sho...

Page 6: ...cutive publication MDHS 14 4 The foam filter specifications and dimensions determine the desired aerosol size selection characteristics and eliminate particle sizes greater than PM10 PM2 5 or Respirab...

Page 7: ...m producing spurious results The system incorporates an Apex2 sampling pump to draw the sample air through the inlet pipe at a user selected flow rate PUF filters are designed to operate at a flow rat...

Page 8: ...ise damage to the instruments could occur Connect the Apex2 pump to the sampling spigot as illustrated in Figure 1 Connect the Microdust probe into the Adaptor Figure 5 When locked correctly into posi...

Page 9: ...a specified mean aerodynamic size it is also possible to weigh the PUF inserts before and after measurement to establish both the total suspended particulate TSP value and the desired size fraction In...

Page 10: ...e Always handle filters with care to prevent contamination or physical damage It is recommended that even if gravimetric analysis is not being performed a GFA filter P102051 is still used to prevent p...

Page 11: ...atic flow control circuitry is used to maintain a stable sample flow rate over varying pressure drop conditions PUF filters are designed to operate at a flow rate of up to 3 5 L min refer to the Apex...

Page 12: ...d premises We will be happy to Provide quotations for individual repairs or provide annual maintenance under contract We recommend factory service by technicians trained and equipped to repair your in...

Page 13: ...ge humidity range 0 to 90 RH in the absence of condensation Size 410 x 330 x 175 mm Apex2 Flow range 0 8 to 5 0 L min Flow control accuracy 5 for selected flow Status indicators Red Blue LED Dimension...

Page 14: ...Spare clear cassette P102113 Filter support pad 37mm pack of 100 P102051 Gravimetric GFA filter 37mm pack of 100 TUC139 Spigot 90 Degree from clear cassette TUC133 Luer connector from TUC133 to ID tu...

Page 15: ...casellasolutions com WEEE INFORMATION FOR EU MEMBER STATES ONLY The use of the WEEE symbol indicates that this product may not be treated as household waste By ensuring this product is disposed of cor...

Reviews: