The Dust Detective does not present a safety risk when you use it as instructed in this User Manual. 
However, it is possible that the environment where you use the instrument may present a safety risk. 
For this reason, always follow correct, safe working practices.

 

The  Microdust  Pro  and  associated  Static  Sampling  Unit  is  non-intrinsically  safe  and  MUST  NOT  be  used 
within a hazardous area. 

DISPOSAL  OF  BATTERIES:  Batteries  and  battery  packs  must  never  be  disposed  of  by  placing  in  a  fire  or 
incinerator, nor must they be punctured, crushed or otherwise mutilated or opened up in any way. Disposal 
must be in accordance to local environmental legislation. 

Ensure the Apex2 and Microdust Pro are held firmly by the Velcro straps provided, otherwise damage to the 
instruments could occur. 

All  optical  measurement systems  are sensitive  to  the  presence  of  moisture  droplets  both  in  the  air  and 
bonded to particulate matter. To prevent possible measurement errors, the system should not be used in 
conditions of high humidity, rainfall or condensation. 

The purge valve must not be closed during operation. Failure to open it will result in pump shutdown errors. 

Summary of Contents for Dust-Detective

Page 1: ...L Static Air Sampling Enclosure HB3341 07 November 2018 Casella Regent House Wolseley Road Kempston Bedford MK42 7JY T 44 0 1234 844 100 F 44 0 1234 841 490 E info casellasolutions com www casellasolu...

Page 2: ...ation 7 Storage of PUF Filters 7 PUF Filter Adaptor 8 Inserting Removing PUF Filters 8 Collection Filter Cassette 9 Starting measurements 10 Checking Probe Span 10 Sampling Pump 10 Service 11 Technica...

Page 3: ...d of by placing in a fire or incinerator nor must they be punctured crushed or otherwise mutilated or opened up in any way Disposal must be in accordance to local environmental legislation Ensure the...

Page 4: ...from those in the manual If there are any questions please contact Casella for clarification Casella makes continual advancements in its products and services We therefore reserve the right to make ch...

Page 5: ...ssory provides a simple solution for short to medium term fixed area monitoring with the Microdust Pro and Apex2 sampling pumps and is designed specifically for use in indoor applications but some sho...

Page 6: ...cutive publication MDHS 14 4 The foam filter specifications and dimensions determine the desired aerosol size selection characteristics and eliminate particle sizes greater than PM10 PM2 5 or Respirab...

Page 7: ...m producing spurious results The system incorporates an Apex2 sampling pump to draw the sample air through the inlet pipe at a user selected flow rate PUF filters are designed to operate at a flow rat...

Page 8: ...ise damage to the instruments could occur Connect the Apex2 pump to the sampling spigot as illustrated in Figure 1 Connect the Microdust probe into the Adaptor Figure 5 When locked correctly into posi...

Page 9: ...a specified mean aerodynamic size it is also possible to weigh the PUF inserts before and after measurement to establish both the total suspended particulate TSP value and the desired size fraction In...

Page 10: ...e Always handle filters with care to prevent contamination or physical damage It is recommended that even if gravimetric analysis is not being performed a GFA filter P102051 is still used to prevent p...

Page 11: ...atic flow control circuitry is used to maintain a stable sample flow rate over varying pressure drop conditions PUF filters are designed to operate at a flow rate of up to 3 5 L min refer to the Apex...

Page 12: ...d premises We will be happy to Provide quotations for individual repairs or provide annual maintenance under contract We recommend factory service by technicians trained and equipped to repair your in...

Page 13: ...ge humidity range 0 to 90 RH in the absence of condensation Size 410 x 330 x 175 mm Apex2 Flow range 0 8 to 5 0 L min Flow control accuracy 5 for selected flow Status indicators Red Blue LED Dimension...

Page 14: ...Spare clear cassette P102113 Filter support pad 37mm pack of 100 P102051 Gravimetric GFA filter 37mm pack of 100 TUC139 Spigot 90 Degree from clear cassette TUC133 Luer connector from TUC133 to ID tu...

Page 15: ...casellasolutions com WEEE INFORMATION FOR EU MEMBER STATES ONLY The use of the WEEE symbol indicates that this product may not be treated as household waste By ensuring this product is disposed of cor...

Reviews: