9 - ACCESSORIES
Setting ranges for Multi-function auxiliary high-flow hydraulic circuit
The setting ranges of the Multi-function auxiliary high-flow hydraulic circuit are related to the circuit mode selected by
the specific page. If breaker page has been selected (Single-acting mode), the maximum flow rate can be selected
within Level 1 and Level 10 in the table below. If crusher page has been selected (Double-acting mode), the maximum
flow rate can be selected within Level 1 and Level 20 in the table below.
Level
1 pump flow
Level
2 pumps flow
1
71 L/min
(
18.8 US gpm
)
11
430 L/min
(
113.6 US gpm
)
2
101 L/min
(
26.7 US gpm
)
12
460 L/min
(
121.5 US gpm
)
3
131 L/min
(
34.6 US gpm
)
13
490 L/min
(
129.4 US gpm
)
4
161 L/min
(
42.5 US gpm
)
14
520 L/min
(
137.4 US gpm
)
5
191 L/min
(
50.5 US gpm
)
15
550 L/min
(
145.3 US gpm
)
6
221 L/min
(
58.4 US gpm
)
16
580 L/min
(
153.2 US gpm
)
7
251 L/min
(
66.3 US gpm
)
17
610 L/min
(
161.1 US gpm
)
8
282 L/min
(
74.5 US gpm
)
18
641 L/min
(
169.3 US gpm
)
9
312 L/min
(
82.4 US gpm
)
19
671 L/min
(
177.3 US gpm
)
10
342 L/min
(
90.3 US gpm
)
20
701 L/min
(
185.2 US gpm
)
The maximum flow rate for Breaker 1 combination and the maximum flow rate for Crusher 1 combination are set from
factory:
Breaker 1:
282 L/min
(
74.5 US gpm
)
Multi-function circuit
Crusher 1:
641 L/min
(
169.3 US gpm
)
If the circuit is set in the Single acting mode, the message CHECK FLOW RATE appears at the bottom of the
setting tab if a value above Level 10 is selected. If attachment operation is anyway started with this setting, the
message CHECK FLOW RATE will appear on the top of the display, and a warning buzzer will sound.
Stop attachment operation, and make sure to select a value of maximum flow rate that does not exceed Level 10.
The maximum working pressure of the circuit can be set according to the mode selected by the specific page. If
breaker page has been selected (Single-acting mode), the maximum working pressure can be set within the following
range:
Multi-function circuit (Breaker mode)
14.0 – 34.5 MPa
(
2030.7 – 5004.2 psi
) (in 0.5 increments)
If crusher page has been selected (Double-acting mode), the maximum working pressure can be set within the fol-
lowing range:
Multi-function circuit (Crusher mode)
14.0 – 34.5 MPa
(
2030.7 – 5004.2 psi
) (in 0.5 increments)
The maximum working pressure for Breaker 1 combination and the maximum working pressure for Crusher 1 com-
bination are set from factory:
Breaker 1:
14.0 MPa
(
2030.7 psi
)
Multi-function circuit
Crusher 1:
14.0 MPa
(
2030.7 psi
)
9-11
Summary of Contents for CX490D
Page 8: ......
Page 40: ...2 SAFETY INFORMATION SMIL20CEX0681HB 2 2 18 ...
Page 81: ...3 CONTROLS AND INSTRUMENTS Rear camera view operating mode SMIL19CEX2626HB 5 3 29 ...
Page 154: ...3 CONTROLS AND INSTRUMENTS 3 102 ...
Page 178: ...4 OPERATING INSTRUCTIONS 4 24 ...
Page 243: ...6 MAINTENANCE Bucket cylinder bottom pin one grease fitting SMIL15CEXY538AB 7 6 49 ...
Page 298: ...8 SPECIFICATIONS Working ranges CX490D LC SMIL19CEX2007HB 5 8 10 ...
Page 300: ...8 SPECIFICATIONS Working ranges CX490D RTC SMIL19CEX2008HB 6 8 12 ...
Page 302: ...8 SPECIFICATIONS Working ranges CX500D LC SMIL19CEX2009HB 7 8 14 ...
Page 304: ...8 SPECIFICATIONS Working ranges CX500D RTC SMIL19CEX2010HB 8 8 16 ...
Page 366: ...9 ACCESSORIES 9 60 ...