background image

Page 3 of 6

ASSEMBLY INSTRUCTIONS  (continued)

ASSEMBLY INSTRUCTIONS  (continued)

C

B

 

Sensor Adjustment Lower For Short Coverage

Sensor Adjustment Higher For Long Coverage

Fig. 2

Fig. 3

Adjusting the Light Head (B) 

Sensitivity of Motion Sensor 

       ● You can adjust the sensitivity of the motion sensor by using the “SENSITIVITY” selector located on the right 

           side of the bottom surface of the sensor. (See Fig. 5)

       ● Adjust motion sensor sensitivity to HIGH (H), MEDIUM (M), or LOW (L) to achieve desired performance.

       ● Approximate range for each setting: 20 ft. (L), 45 ft. (M), 70 ft. (H).

Note: When power is first applied, the light will turn on to 100% brightness. The sensor will take 30 seconds

to warm up.

1. AUTO MODE (nighttime operation only)

After expiration of the warm-up period, the light will enter a 5-minute TEST mode (day and night operation) and be on

at low-level brightness (0-50%). The light will turn to high-level brightness (100%) when motion is detected. It will then

revert to low-level brightness about 5 seconds after motion is no longer detected.

     

Adjusting the Sensor Head (C) 

1. Aim sensor head toward desired detection area, maintaining a

    5° - 40° downward angle to allow moisture to drain.

    Note: Make sure sensor head is positioned with control knob facing

    towards the ground.

2. You can rotate the sensor head (C) up and down to change the 

    coverage area. (See Fig. 1) Walk through the detection zone at the 

    farthest distance you wish to detect motion.

    Note: Range set too high may increase false triggering.

    (See Fig. 2,3)

 

Fig. 1

1. Gently grasp the light heads  (B) and tilt them up or down, left or right to adjust the light coverage area.

    Keep the light heads (B)  at least 1” (25mm) away from the sensor.(See Fig. 4)

2. Keep the light heads (B) 30˚ below horizontal to avoid water damage and electrical shock.

   

    ●  

Fig. 4

Fig. 5

Mode

Sensitivity

ASSEMBLY INSTRUCTIONS (continued)

ASSEMBLY INSTRUCTIONS  (continued)

ASSEMBLY INSTRUCTIONS  (continued)

FUNCTION AND OPERATION  (continued)

Summary of Contents for T0460

Page 1: ...are not familiar with state and local electrical codes it is recommended that you consult with a qualified electrician 2 This fixture requires a 110 120 VAC 60 Hz power source 3 For general safety and to avoid any possible damage to the sensor be sure the power is switched off before adjustment Maximum Wattage 33 W Working Temperature Range 4 F 113 F ASSEMBLY AND INSTALLATION INSTRUCTIONS NOTES 1 ...

Page 2: ...ounting screw hole on the light fixture 2 1 BB BB FF DD DD CC CC AA EE 3 4 4 Place mounting bracket against the outlet box insert the mounting bracket screw FF through the mounting bracket hole thread mounting bracket screw FF into the center hole of the mounting strap BB Tighten the mounting bracket screw FF securely When mounting to a wall the UP arrow must point upward When mounting to an eave ...

Page 3: ...light will turn to high level brightness 100 when motion is detected It will then revert to low level brightness about 5 seconds after motion is no longer detected Adjusting the Sensor Head C 1 Aim sensor head toward desired detection area maintaining a 5 40 downward angle to allow moisture to drain Note Make sure sensor head is positioned with control knob facing towards the ground 2 You can rota...

Page 4: ...conds Fig 7 5 Manual Override nighttime operation only See Fig 7 To shift to the manual override mode set the mode selector to AUTO 3H or 6H mode Turn the wall switch OFF and turn it ON twice within 3 seconds The light will remain on all night long To shift back to AUTO 3H or 6H mode turn the wall switch OFF and turn it ON twice within 3 seconds again The light will turn off automatically at dawn ...

Page 5: ...ollowing parts are available for re order if damaged or missing Spare Parts List 20 8 0 12 0 70 Where you install your fixture is important Be sure the light is mounted straight on the wall or eave otherwise the detection distance may be limited Fig 8 Fig 9 240 AA BB DD FF EE CC Mounting Screw X2 Wire Connector X3 Cross Bar X1 Mounting Bracket Screw X1 Decorative cover X1 Fixture Mounting Screw X1...

Page 6: ... minutes 1 Make sure there is no movement that could be picked up by the sensor 2 Adjust the delay time knob counterclockwise to reduce the delay shut off time In Manual override the light stays on after dawn 1 The ambient light level may be too low due to overcast skies 5 YEAR LIMITED WARRANTY All products are warranted to be free of defects in material and workmanship for five 5 years from date ...