RECEPTION OF THE MERCHANDISE

Each product is checked carefully before shipment. At the time of reception, check that the product has not been damaged during trans-
port; otherwise, communicate the incident to the carrier. The carrier is responsible for possible
damages derived from transportation. The products are packed in pallets and fixed to it by strips and protective film, or in self-supporting 
cardboard boxes, properly fixed to the pallet.

DISPLACEMENT

Before moving the product, make sure that the medium used has adequate capacity. For lifting, use forklifts, lifting the pallet. The maximum 
hand lift is specified in the 89/391 / EEC standard and later. It is generally acceptable
a weight of 20 kg below the back but above ground level.

STORAGE

Store the unit in a sheltered place, without excessive humidity and not subject to strong temperature fluctuations, in order to avoid the 
formation of condensation inside the unit. Storage is not recommended for a period longer than one year. If more than one year is stored, it 
is necessary to check the free rotation of the bearings before installation (turn the turbine by hand).

PROLONGED STOP

In case of prolonged shutdown, with the unit connected to the ventilation system, close the suction / discharge ducts and periodically 
check the absence of humidity inside the machine. In case of moisture formation, dry it immediately.

START

 

UP

Before commissioning, it is advisable to carry out some checks (follow the safety instructions set out in the DISMOUNTING AND ASSEMBLY 
section):
- Make sure that there is no condensation inside the unit, and if necessary dry it before putting the unit into operation.
- Check the status of the filters.
- Make sure that the interior of the product has no foreign bodies and that all the components are fixed in their seats.
- Manually test that the turbine does not rub against the suction mouth of the machine.
- Check that the inspection gate is closed.

ATTENTION:

If the mouths of a fan are not properly holed, a suitable protection net must be provided. Check the electrical ground connection. The 
electrical connection must be made by qualified personnel.

DISASSEMBLY AND ASSEMBLY

Before starting any operation, make sure that the product is not in operation and can not be fed accidentally or accidentally, and that the 
fans are stopped. The disassembly and the corresponding assembly are extraordinary maintenance operations and must be carried out by 
qualified personnel.

ELIMINATION

In accordance with the Directive of the European Parliament 2012/19 / EU on waste electrical and electronic equipment (WEEE) “.

The crossed-out wheeled bin symbol on the appliance or on the packaging indicates that the product, at the end of its useful life, must be 
disposed of separately from the other waste to allow proper treatment and recycling. The user must, therefore, deliver
free of charge the device, when it reaches the end of its useful life, to the corresponding local centers for selective collection of electrical 
and electronic waste, or return it to the distributor according to the following modalities:
- For devices of very small size, or with an exterior side of no more than 25 cm, free delivery without obligation of purchase is foreseen in 
the stores with an area of   sale of electrical and electronic devices superior to 400 m2. For stores with inferior surfaces, this modality is optio-
nal.
- For appliances with dimensions greater than 25 cm, delivery is foreseen in all the points of sale in the 1-for-1 mode, that is, the delivery 
to the distributor may only be made at the time of purchase of a new equivalent product, in reason of one to one. The adequate selective 
collection for the subsequent delivery of the discarded device to recycling, treatment and compatible environmental elimination, helps to 
avoid possible negative effects on the environment and health and favors the reuse and / or recycling of the materials that make up the 
device . The illegal elimination of the product by the user supposes the application of the sanctions foreseen by the current legislation.

Summary of Contents for CEPHIRUS-2 EEC

Page 1: ...www casals com CV072018 1 CEPHIRUS 2 USERMANUALANDINSTALLATION...

Page 2: ...CHANDISE DISPLACEMENT STORAGE PROLONGED STOP START UP ASSEMBLY AND DISASSEMBLY ELIMINATION WIRING DIAGRAMS CONFIGURATIONS CONDENSATE BOARD ACCESSORIES CUT SWITCH ACCESSORIES PRESSURE SWITCH ACCESSORIE...

Page 3: ...ng the power cable to the termi nal board verify that the line voltage is suitable for that shown on the machine s plate pay attention to the labels placed on the product if time goes by they should b...

Page 4: ...nt of defective components according to the following conditions Casals ventilation reserves the right at its own discretion to replace the components of defective products or low value products both...

Page 5: ...rom improper or incorrect uses Consider an area where the air drive and the noise of the unit do not cause discomfort to neighbors Consider a position that respects the minimum spaces as indicated in...

Page 6: ...closed ATTENTION If the mouths of a fan are not properly holed a suitable protection net must be provided Check the electrical ground connection The electrical connection must be made by qualified pe...

Page 7: ...on must be guaranteed in accordance with the following diagrams presented green yellow terra green yellow terra blue neutral blue neutral Phase gray gray phase T T L N N N C L1 L1 black white red CEPH...

Page 8: ...d Control A AV BV B E F I J M N CEPHIRUS 2 CEPHIR CEPHIRUS 2 Aire nuevo Aire extraido Vertical version with control coil module mounted when purchased separately from the product catalogue see for mor...

Page 9: ...n this image Note It must be loaded with a suitable siphon configuration to ensure the correct flow of condensate and avoid odors single phase three phase ACCESSORIES CUTTING SWITCH The installation o...

Page 10: ...gulator of defined pressure Regulator of Pressure diferencial ACCESSORIES CONSTANT FLOW The accessory allows the constant flow to be maintained constant regardless of the variation in pressure drop of...

Page 11: ...equency converter three phase fans or the voltage converter single phase fans being in the case of the frequency converter a percentage value of the operating range selected in the differential pressu...

Page 12: ...flow measurement must be maintained as a function of measurement the adjustment value is adjusted ACCESSORIES CO2 CONTROL Its goal is to monitor the concentration of carbon dioxide in the air in real...

Page 13: ...MENU PI CATEGORY rPI The value of the intended regulation being here imposed ACCESSORIES CO2 CONTROL For the voltage variators the regulation is carried out in the following way Press the A M button c...

Page 14: ...trap must be placed in the highest part of the hydraulic circuit A filter must exist in the hydraulic installation ACCESSORIES ELECTRICAL COIL The electric coil module uses electric heating elements T...

Page 15: ...15 CV072018 1 CEPHIRUS 2 3500 18 kW CEPHIRUS 2 4600 6400 27 kW CEPHIRUS 2 7000 36 kW TP Thermal protection Safety thermostat TP TP TP...

Page 16: ...rop in the overestimated installa tion Check the flow rate and pressure drop The fan speed Reduce the rotation speed Create a pressure drop in the installation Insufficient air flow Air distribution s...

Page 17: ...Tel 34 972720150 Fax 34 972721053 E mail nacional ventilacion casals tv E mail export fans casals tv www casals tv Sr David Samper Dir General Sant Joan de les Abadesses 02 07 2018 DECLARATION OF CONF...

Reviews: