ACCESSORIES - PRESSOSTAT

The differential air pressure switch allows the differential pressure to be monitored between two different points. It is applied to the equip-
ment to collect information about the condition of the filters and also the condition of the fans of the equipment.
The desired pressure differential is set directly on the pressure switch as shown with its electrical connections shown.

Differential regulator

of defined pressure

Regulator of

Pressure diferencial

ACCESSORIES - CONSTANT FLOW

The accessory allows the constant flow to be maintained constant regardless of the variation in pressure drop of the system.
The control of the flow rate is carried out using a relationship between the air flow that moves and the differential pressure as indica-
ted in the images for single-phase fans and three-phase fans.

A - Differential of the pressure sensor.
B - Variator of tension.
C - Fan.

A - Differential of the pressure sensor.
B - Variator of frequency.
C - Fan.

Single phase - CEPHIRUS-2 600/900/1500/2100/3500/4600

Three phase  - CEPHIRUS-2 6400/7000

Summary of Contents for CEPHIRUS-2 EEC

Page 1: ...www casals com CV072018 1 CEPHIRUS 2 USERMANUALANDINSTALLATION...

Page 2: ...CHANDISE DISPLACEMENT STORAGE PROLONGED STOP START UP ASSEMBLY AND DISASSEMBLY ELIMINATION WIRING DIAGRAMS CONFIGURATIONS CONDENSATE BOARD ACCESSORIES CUT SWITCH ACCESSORIES PRESSURE SWITCH ACCESSORIE...

Page 3: ...ng the power cable to the termi nal board verify that the line voltage is suitable for that shown on the machine s plate pay attention to the labels placed on the product if time goes by they should b...

Page 4: ...nt of defective components according to the following conditions Casals ventilation reserves the right at its own discretion to replace the components of defective products or low value products both...

Page 5: ...rom improper or incorrect uses Consider an area where the air drive and the noise of the unit do not cause discomfort to neighbors Consider a position that respects the minimum spaces as indicated in...

Page 6: ...closed ATTENTION If the mouths of a fan are not properly holed a suitable protection net must be provided Check the electrical ground connection The electrical connection must be made by qualified pe...

Page 7: ...on must be guaranteed in accordance with the following diagrams presented green yellow terra green yellow terra blue neutral blue neutral Phase gray gray phase T T L N N N C L1 L1 black white red CEPH...

Page 8: ...d Control A AV BV B E F I J M N CEPHIRUS 2 CEPHIR CEPHIRUS 2 Aire nuevo Aire extraido Vertical version with control coil module mounted when purchased separately from the product catalogue see for mor...

Page 9: ...n this image Note It must be loaded with a suitable siphon configuration to ensure the correct flow of condensate and avoid odors single phase three phase ACCESSORIES CUTTING SWITCH The installation o...

Page 10: ...gulator of defined pressure Regulator of Pressure diferencial ACCESSORIES CONSTANT FLOW The accessory allows the constant flow to be maintained constant regardless of the variation in pressure drop of...

Page 11: ...equency converter three phase fans or the voltage converter single phase fans being in the case of the frequency converter a percentage value of the operating range selected in the differential pressu...

Page 12: ...flow measurement must be maintained as a function of measurement the adjustment value is adjusted ACCESSORIES CO2 CONTROL Its goal is to monitor the concentration of carbon dioxide in the air in real...

Page 13: ...MENU PI CATEGORY rPI The value of the intended regulation being here imposed ACCESSORIES CO2 CONTROL For the voltage variators the regulation is carried out in the following way Press the A M button c...

Page 14: ...trap must be placed in the highest part of the hydraulic circuit A filter must exist in the hydraulic installation ACCESSORIES ELECTRICAL COIL The electric coil module uses electric heating elements T...

Page 15: ...15 CV072018 1 CEPHIRUS 2 3500 18 kW CEPHIRUS 2 4600 6400 27 kW CEPHIRUS 2 7000 36 kW TP Thermal protection Safety thermostat TP TP TP...

Page 16: ...rop in the overestimated installa tion Check the flow rate and pressure drop The fan speed Reduce the rotation speed Create a pressure drop in the installation Insufficient air flow Air distribution s...

Page 17: ...Tel 34 972720150 Fax 34 972721053 E mail nacional ventilacion casals tv E mail export fans casals tv www casals tv Sr David Samper Dir General Sant Joan de les Abadesses 02 07 2018 DECLARATION OF CONF...

Reviews: