background image

2

Calculation of 32°

Use the tear-off 

Ceiling Angle Template

 card inserted in the 

back of this manual, it provides you with a simple “go” or 
“no-go” for installing your fan on a sloped ceiling.

SLOPED CEILING INSTALLATIONS

MOUNTING RECOMMENDATIONS

7

 MINIMUM

Pole Length

standard
standard

18”
18”
24”
36”
48”

Ceiling Height

10

10

 6”

11

11

 6”

12

13

 

14

Suggested Extension Pole Lengths

When to Use Extension Poles

For best performance and best appearance, 
an extension pole should be used with 
your Casablanca fan when installing on 
high (cathedral) ceilings or sloped ceil-
ings. Casablanca offers standard poles in 
increments of 6

 up to 5

. Custom poles 

are available in lengths up to 10’. See your 
Authorized Casablanca Dealer for details.

32°

BLADES MUST BE 

A MINIMUM OF 7

′ 

ABOVE THE FLOOR

EXTENSION 

POLE

MAXIMUM 

HANG-TRU® 

ANGLE 32º

Before mounting your Casablanca fan, read the following helpful recommendations. The location of the fan, air circulation, 
and fan size are all important factors to consider before installation.

Location

Ceiling fans have practical uses in almost every room in your home. We suggest you follow these mount-
ing recommendations as you decide where to install your Casablanca fan. 
•  For safety reasons, the fan blades must be a minimum of 7

 above the fl oor. 

•  Do not locate the fan in a doorway or above a swinging door. 
•  In any installation, the tips of the blades must be at least 18” from the wall in order to 

provide suffi cient clearance for the blades.

•  In bedrooms, fans work best when mounted above the foot of the bed.
•  Over pool tables, be sure to provide plenty of clearance to avoid damage from 

pool cues.

•  In kitchens be sure to allow for open cupboard doors to clear the fan blades.
•  Do not install a fan close to, or over, a pool or spa. High humidity combined 

with corrosive gases will destroy the fi nish and warp the blades.

Fan Size

Variable fan speed capability permits the use of a full-size 52" fan even in 
smaller rooms. For very large rooms, two fans may be needed.

EXAMPLE 1

This slope is less than 32

º

.

It is OK to install your fan.

EXAMPLE 2

This slope is 32

º

.  This is the maximum 

slope that will allow the fan to hang 
straight down.  It is OK to install your 
fan.

EXAMPLE 3

This slope is more than 32

º

.

Your fan will not hang straight down, an 
adaptor is necessary.  Contact your local 
Authorized Casablanca Dealer in regards to 
purchasing a “Sloped Ceiling Adapter.”

Note:

 Fan may wobble or vibrate if 

pole length is not long enough and 
inside blade is too close to downslope 
or side wall. Extending pole length 
usually will solve problem.

CAUTION: Installation of this fan requires 
a minimum 10-foot ceiling.

Summary of Contents for Verrazano

Page 1: ...e UL Listed for ceiling fan installations If it is not a new box must be installed Casablanca extension poles are available for sloped or high ceiling installations This ceiling fan requires a grounde...

Page 2: ...ons the fan blades must be a minimum of 7 above the floor Do not locate the fan in a doorway or above a swinging door In any installation the tips of the blades must be at least 18 from the wall in or...

Page 3: ...body warranty card owner s manual and all the parts necessary to assemble and install your Casablanca ceiling fan These parts are shown at the start of each installation section Before you start go th...

Page 4: ...hole into the joist or beam to a depth of 3 Step 2 Route the outlet box wires through the keyhole slot of the crossbar mounting bracket as shown Attach the crossbar mounting bracket to outlet box with...

Page 5: ...opening toward the top or peak of the room CANOPY HARDWARE CANOPY CANOPY HATCH CANOPY LOCK WASHER 4 CANOPY SCREW 4 Step 3 With the large washer attached pass the lag screw through the center hole of t...

Page 6: ...ANSI NFPA 70 1993 and local codes RED YELLOW BLACK BLACK WHITE GREEN WIRE NUT BLACK YELLOW 2 WHITE RED AND BLUE D 1 3 GREEN GROUND 120V AC Inspect each wire nut and ensure that no bare wire is vis ib...

Page 7: ...Remove the three wires from the switch 5 Wiring preparation if required Strip wires 3 8 for 14 guage 1 2 for 16 and 18 guage NOTE The wire connectors provided are suitable for copper wire only Use to...

Page 8: ...securely by hand only BLADE TIP BLADETIP INSTALLATION BLADE BLADE SCREW 3 PER BLADE BLADE ROD BLADE ROD HOLDER SCREW PRE INSTALLED SHIPPING COVER Note Do NOT install the rub ber tipped end into the bl...

Page 9: ...g Using the three switch housing screws removed in Step 13 attach the light kit base to the switch housing LIGHT KIT PARTS LIGHT KIT SCREWS REMOVE SWITCH HOUSING SCREWS Step 13 Remove the three screws...

Page 10: ...ouched or dirty clean carefully with a tissue A dirty glass bulb will cause the bulb to fail almost immediately Step 17 Position the indentations in the outer rim of the glass shade so that they line...

Page 11: ...ion your fan should go in summer and winter Summer Counterclockwise Winter Clockwise REVERSE SWITCH IN SUMMER the movement of air creates a cooling wind chill effect A room can actually feel several d...

Page 12: ...bly PCB assembly or motor unit FAN WILL NOT OPERATE AT PROPER SPEEDS OR WILL NOT OPERATE AT ANY SPEED Defective three speed pull chain switch assembly or defective capacitor replace three speed pull c...

Page 13: ...ERING SEA ECCOTECH 907 227 3171 FFS ARIZONA GREEN VALLEY 85614 GOBLE ELECTRIC 520 625 4938 IHO MESA 85204 GALLERY OF FANS 480 962 0477 FFS PHOENIX 85016 THE FAN DOCTOR 602 274 6649 IHO PHOENIX 85019 F...

Page 14: ...A 59801 WESTERN MONTANA LIGHTING SUPPLY406 543 7166 ISO STATE CITY ZIP SERVICE CENTER NAME PHONE TYPE NEBRASKA GRAND ISLAND 68803 QUALITY SEW VAC 308 382 7310 ISO LINCOLN 68510 LINCOLN LIGHTING CENTER...

Page 15: ...78404 BRAND APPLIANCE MICROWAVE 361 854 1851 ISO DALLAS 75206 LIGHTS FANTASTIC 214 369 1101 FFS DAMON 77430 GULF COAST FAN SVC 281 495 6434 FFS DENTON 76201 LARRY W GOFF 940 387 7304 IHO DENTON 76210...

Reviews: