background image

 

 

PW-II

 Service Manual

   

 

2.1.1.

 

C4 Setting 

2.1.1.1.

 

C4-1 Setting 

B7 

B6 

B5 

B4 

B3 

B2 

B1 

B0 

 

Weight 

Unit 

External 

Resolution 

Display Unit 

TARE 

 

0:kg 

1:lb 

00: Low 

01: High 

00:kg 

01:lb 

10:oz 

11:g 

00: (+)One Time (-) One Time 
01: (+)Successive (-) One Time 
10: (+)One Time (-) Successive 
11: (+)Successive (-)Successive 

 

User should input Hexa code to set C4.   
User should input “weight unit”, “external resolution”, “display unit”, and “tare”. 
For example, if you want to set “kg (0)” as the weight unit, “low (00)” as the external 

resolution, or “(0)” as TARE you may input “00” as Hexa value. 

User can set 2,000~2,500 for low external resolution or 4,000~5,000 for high external 

resolution. 
 
 
2.1.1.2.

 

C4-2 Setting   

Capacity Setting 

UNIT 

kg 

lb 

oz 

C4-2 Value 

2 2,000 5  80 

0000  1XXX 

5 5,000 10  160 

0001  1XXX 

10 10,000 20  400 

0010  1XXX 

PW-II has four different weight units, g, kg, lb, or oz as shown in shaded area. You can set 

the capacity to input first 5 bits, for example, “00011” for 5 kg capacity.   

Next three (3) bits represent “Interval” information. For example, if you set 5 kg interval the 

Hexa value will be “0x18”.   
 
 
2.1.1.3.

 

C4-3 Setting (Function Setting) 

ROM VERSION 1 (Hold) 

ROM Version 2 (lb) 

Function Function 

S-HOLD XXXX 

XX00 

HOLD XXXX 

XX00 

Lb XXXX 

XX10 

Downloaded from 

www.Manualslib.com

 

manuals search engine

 

Summary of Contents for PW-10H

Page 1: ...PW II Service Manual 1 PW II SERVICE MANUAL Downloaded from www Manualslib com manuals search engine...

Page 2: ...g 9 2 1 1 4 C4 4 Setting 9 2 1 1 5 C4 5 4 6 Setting 10 2 1 2 SPAN Calibration Setting C 3 10 2 1 3 Gravity Constant Value Setting C 9 11 2 1 4 Displaying Real A D Value C 5 11 2 1 5 How to confirm SPA...

Page 3: ...1 Main PCB Ass y 22 6 1 2 Battery PCB Ass y 23 6 1 3 Key PCB Ass Y 23 6 2 Mechanism Part 24 6 2 1 Body Ass y 24 6 2 2 C T Box Ass y 25 6 2 3 Loadcell Ass y 25 7 Error Message Solution 26 7 1 Beep Re...

Page 4: ...scale into the proper power outlet Place the scale on a flat and stable surface Plug into a power outlet 30 minutes before operations Keep the scale away from strong EMI noises may cause incorrect wei...

Page 5: ...20 lb 0 005 lb 400 oz 0 1 oz 1 4 000 Internal Resolution 1 20 000 1 25 000 1 20 000 External Resolution 1 2 000 1 2 500 1 2 000 Display 91 X 39 mm 3 6 X 1 5 inch 5 digits LCD Symbols Indicators STABL...

Page 6: ...stable This weight is average value UNIT Used to convert the unit of weight TARE To input or cancel the tare the weight of container ZERO O Set To set zero point To do SET key in the SETUP mode POWER...

Page 7: ...PW II Service Manual 7 1 5 Sealing Method Downloaded from www Manualslib com manuals search engine...

Page 8: ...n Mode Pressing and holding Calibration Switch press POWER key It displays C 0 after CAL and it blinks the version of scale three times 2 Selecting menu press TARE and then HOLD 3 ENTER Setting ZERO k...

Page 9: ...value User can set 2 000 2 500 for low external resolution or 4 000 5 000 for high external resolution 2 1 1 2 C4 2 Setting Capacity Setting UNIT kg g lb oz C4 2 Value 2 2 000 5 80 0000 1XXX 5 5 000...

Page 10: ...essing and holding Calibration Switch press POWER key After CAL message blinks three times and shows the version of scale it displays C 0 message 2 Press TARE to display C 3 3 Press ZERO key and then...

Page 11: ...HOLD and TARE key 5 Press ZERO key and then G 2 message blinks 9 7994 will be shown The first digit 9 will blink 6 Input a gravitational acceleration value by using HOLD and TARE key 7 Press ZERO key...

Page 12: ...increase the value For example when you weigh maximum capacity on the platter in case of 1 20 000 it may display 19 999 or 20 001 You can adjust up or down to 20 000 using HOLD or TARE key 5 Press ZE...

Page 13: ...START C 4 C 4 1 C 4 2 Display Unit TARE Option C 4 6 Unit Change C 9 Gravity 1 2 G 1 G 2 C 3 SPAN UnLOAd LOAd 3 C 1 Trim m ing 4 Factored Value LOAd Up Down END Capacity Interval C 4 4 Initial Zero D...

Page 14: ...s and Diagram 3 1 System Block Diagram Load Cell A D Converter ADS1100 CPU NEC 78Fseries KEY EEPROM 24C02 AMP Filter POWER DC 9V 300mA Battery_AA SIZE 1 5V x 6 LCD Driver DISPLAY LCD Downloaded from w...

Page 15: ...K 1F 1G 1E 1D 1A 1B 1C 1P 1Z S 2 S 3 S 4 HI 2A 2B 2C 2P 2Z 3F 3G 3E 3D 3A 3B 3C 3P 3Z 4F 4G 4E 4D 4A 4B 4C 4P 4Z 5F 5G 5E 5D 5A 5B 5C O Z LB K G 2F 2G 2E 2D P CS VDD AUTO POWER 2 E C11 30p R22 100 U2...

Page 16: ...Document Number Rev Date Sheet of R21 150K VDD C105 C2 330u A4 MMZ1608Y102C L2 471u MMZ1608Y102C R17 100k VIN L1 471u L7 1 2 J2 L C CON 1 1 2 3 4 5 6 7 8 9 10 L10 1 2 SIG C18 0 1uF C20 1 uF MMZ1608Y10...

Page 17: ...PW II Service Manual 17 4 Exploded View Downloaded from www Manualslib com manuals search engine...

Page 18: ...PW II Service Manual 18 5 Part Location 5 1 Main PCB Front Downloaded from www Manualslib com manuals search engine...

Page 19: ...PW II Service Manual 19 5 2 Main PCB Rear Downloaded from www Manualslib com manuals search engine...

Page 20: ...PW II Service Manual 20 5 3 BATTERY PCB Downloaded from www Manualslib com manuals search engine...

Page 21: ...PW II Service Manual 21 5 4 KEY PCB Downloaded from www Manualslib com manuals search engine...

Page 22: ...0022 0 RESISTOR CHIP 1 10W FTR 0805 222 JR 2 2K EA 1 6527 IJ3 0100 0 RESISTOR CHIP 1 10W FTR 0805 103 JR 10K EA 7 6527 ID3 0300 0 RESISTOR CHIP 1 10W RR1220P 303D 30 EA 2 6527 ID3 0499 0 RESISTOR CHI...

Page 23: ...Parts Code Parts Name Unit Q ty 6140 PPW 0000 0 PCB BATTERY 6140 PPW 0000 0 PW II EA 1 1060 A00 0010 0 BATTERY CONTACT 12 10 7 5 0 4t PORTION EA 12 1590 A00 0005 0 COIL SPRING 0 5 8 2 5 4 PW EA 6 7809...

Page 24: ...MSU 0408 0 SCREW MACHINE PH M4 8 SUS EA 3 18 1530 MSU 0510 0 BOLT WRENCH M5 1 0 10 SUS EA 6 15 16 1540 A00 0300 0 NUT HEX M3 0 5 EA 4 19 1561 MSU 0300 0 E RING 3 7 0 6 SUS EA 1 21 1810 PW0 0033 0 SPEC...

Page 25: ...2 9203 AS0 0001 0 STYROFOAM BOX 301 109 80 PORTION SET 1 9301 A00 0003 0 POLY BAG 170 250 0 05T MANUAL EA 1 9301 A00 0004 0 POLY BAG 190 260 0 03T DISPLAY EA 1 9302 A00 0005 B POLY BAG 270 350 0 04T M...

Page 26: ...0 of full capacity by decreasing the value of weight 7 3 Init Failure of Analog Module Init message shows up when there is some problem on analog module Please turn off the scale and turn on If you st...