- 40 -
12 - 1. HOW to SET the Original Number (Product ID) of Goods
STEP
VFD DISPLAY and KEY INPUT
PLATFORM
DESCRIPTION
1 0kg
Empty
2 1500kg
Goods(Iron)
Weight(1500kg)
3
Press [G/N] key for 2
~
3 seconds.
Display :
“CodE=z LiM=t tArE=g”
201
Display :
“On” -> “ID”
200
“COdE”
4
Press [ZERO] key and input 10
201
Input product ID 200
Input ID(=10) of iron
5
Press [ENTER] key
Goods(Iron)
Show the ID of goods
Display the weight
Note 1.
The ID of goods can be from 0 to 19.
12 - 2. HOW to INPUT the Value of Maximum and Minimum
STEP
VFD DISPLAY and KEY INPUT
PLATFORM
DESCRIPTION
1 0.0kg
Empty
2 150.0kg
Goods(Iron)
3
Press [G/N] key for 2
~
3 seconds
Display :
“CodE=z LiM=t tArE=g”
4
Press [TARE] key and then
display “HI”
5
Input the value of 1,000
Iron
Maximum : 100.0kg
6
If it’s displayed the “LO”,
Input the value of 900.
Iron Minimum
:
90.0kg
7
Press [ENTER] key
Iron
It is input the Max.
and
Min. value in this ID
Note 1.
If the weight is larger than maximum, display
"
HI
"
.
If the weight is smaller than minimum, display
"
LO
"
.
If the weight is between maximum and minimum, display
"
OK
"
.
It is possible for F06 to set 2 (checker).
12 - 3. HOW to INPUT the VALUE OF TARE DIRECTLY
STEP
VFD DISPLAY and KEY INPUT
PLATFORM
DESCRIPTION
1
Press [TARE] key for 2
~
3 seconds
Empty