PERCENT MODE(
Ⅲ
)
INITIAL DISPLAY
DESCRIPTION
Percent Mode
(
) Press the [TARE] key long to set the Percent Mode in detail
Ⅲ
DISPLAY
KEY
DESCRIPTION
ZERO
After weighing the weight of 100%,
go to the percent weighing mode
TARE
After weighing the weight of 100% with key,
go to the percent weighing mode
End
ENTER
Go to the percent weighing mode
(
Ⅲ
- 1) In the case of pressing the [ZERO] key
DISPLAY
KEY
DESCRIPTION
SAMPLE
Sample weight input state
UnLoAd
Unload
display
A/D (24750)
ENTER
Display unload value
LoAd
A/D (24750)
ENTER
After put a sample weight on the platform,
press [ENTER] key
Good / Per
10 %
After checking the message “Good” “Per”
10
Input the number what you want
(Ex) 10kg(sample) 10, the weight of 1% is 1kg
Good
ENTER
After save, go to initial display of percent mode
ENTER It is displayed and then go to percent mode
(
Ⅲ
- 2) In the case of pressing the [TARE] key
DISPLAY
KEY
DESCRIPTION
Input the weight of sample with key.
Set the 20.00kg to 100%
WEiGht
20.00 kg
ENTER
After saving,
go to initial display of percent mode
If the weight of sample is over the maximum
Err 08
Capacity(Err08) or small(Err32), return
ENTER It is displayed and then go to percent mode
SAMP = Z
In = t
on