9
Operation Instructions
1. Turn on the power supply and select a suitable vacuum packing bag for the product.
2. Set the processing parameter and select the sealing temperature. For the details, please refer
to Pages 4~6.
3. Place the vacuum bag at the chamber with the opening end on top of the sealing bar. Clamp
it with the hook provided.
4. Close the acrylic cover (For electric or pneumatic driven series, just press the start button)
and the machine will complete the processing procedure automatically.
5. During processing, the vacuum chamber will form a vacuum self-lock state, the whole
heating and sealing procedure are completed in a vacuum environment, and the LED display
on panel shows the flow process.
6. When the vacuum indicator on panel lights, the equipment is under vacuum state, the LED
display shows the timing of vacuum time, and it will enter into the next work state
automatically after the timing is finished.
7. When the nitrogen filling indicator on panel lights, the equipment is under filling state, the
LED display shows the reverse timing of filling time, and it will enter into the next work state
automatically after the reverse timing is finished. For some models, this function is disable,
and this indication shows disable state when operation. After that, it moves to heating state
disable.
8. When heating indicator lights, the equipment enters into heating work state, and the panel
shows the reverse timing of heating. It will enter into cooling state automatically after the
timing is finished. (For a common machine model, there isn’t cooling time set, the cover
opens directly after the heating is finished.)
9. According to time setting, the machine doesn’t act when cooling, the panel shows “
□□
” till
the reverse timing is finished, air is returned, the cover opens automatically, and the whole
processing is finished. Then prepare the next cycle. (For electric or pneumatic cover opening
model, the gas release time is calculated; the cover opens automatically after gas release time
ended.) For a common machine model, there isn’t cooling step, and the cover opens directly.
10. Press the E-Stop button for a sudden condition under processing state, the machine will go
to return-air action automatically (for the intelligent model, the panel shows “
□□
”), the cover
opens automatically after return-air action, so the processing ends.