7
Setting
Please set every parameter first before starting machine for operation.
For different machine model, please refer to this chapter.
Setting of common model :
1. Connect to the power supply, turn on power switch, the indicator lamp lights. Set the time
relay to adjust the vacuum and sealing timing. (The front two figures show the time of
vacuum : e.g. 28 means 28 seconds, the back two figures show the time of sealing: e.g.12
means 1.2 seconds.)
The times of vacuum and sealing can be adjusted through pressing “+” or “-“ button. (Some
model adopts knob adjustment, location of knob depend on the model.)
2. The selection switch on panel adjusts the heating temperature, HIGH represent high
temperature, LOW represent low temperature and the MIDDLE represent middle heating.
(The temperature adjustment of double-room machine model is divided into four switches.)
3. For setting in vacuum timing, try to set longer timings and observe the vacuum meter when
it reach -0-1 Mpa. Add 1-2s to the timings when it reaches -0.1Mps for your vacuum timings.
As for the sealing timings, test the bag, advice to test start from low apply both to vacuum and
sealing applications.
4. Watch out for any abnormal sound creation to the vacuum pump when running it. Ensure
all adjustment and trial is tested before production.
Intellingent Series :
1. Turn on the power supply, check through the setting shows on the panel and make sure
“-----“ must be shown after setting is done. Otherwise, operation of this machine cannot be
function if the setting is not on this mode.
2. Press the setting button, the indicator lamp of vacuum lights to enter into the setting state of
vacuum timing. Press the upward or downward key to increase or decrease vacuum time in
the range of 0~99 seconds.
3. After the vacuum time is set, press the set key and the nitrogen filling indicator lamp lights
to enter into the setting state of nitrogen filling. Press the upward or downward key to increase
or decrease nitrogen filling time in the range of 0~9.9 seconds.
Note: Some models of our machine do not have nitrogen filling function, hence; set the timing to
0 for best result.
4. Press the parameter set key, heating indicator lamp lights to enter into heating setting state.
Press the upward or downward key to increase or decrease the heating sealing time in the
range of 0~9.9 seconds. The time setting should be from low timing and gradually to higher
timings.
5. After the heating time is set, press the set key again, cooling indicator lamp lights to enter
into the setting state of cooling time in the range of 0~9.9 seconds.
6. After the cooling time is set, press the set key again to finish the parameter setting, and
“Ed” is shown in panel.