2
Page 1: ...2 ...
Page 2: ... INSTRUCTIONS MANUAL 4 USE AND CHARACTERISTICS 5 PREPARATION BEFORE USE 6 OPERATION INSTRUCTIONS 9 GAS CIRCUIT SCHEMATIC DIAGRAM 11 ELECTRIC SCHEMATIC DIAGRAM 13 BREAKDOWN ANALYSIS 20 TECHNOLOGY SPECIFICATIONS 22 ...
Page 3: ...ng 0 9 9S Heating 0 9 9S Cooling 0 9 9S Gas release Intelligent Series 3 Air exhaustion to vacuum 0 99S Slivering 0 9 9S Heating 0 9 9S Cooling 0 9 9S Gas release Intelligent Series 4 Air exhaustion to vacuum 0 99S Heating 0 9 9S Cooling 0 9 9S Gas release Standard Series Air exhaustion to vacuum 0 99S Heating 0 9 9S Cooling 0 9 9S Gas release The flow chart circuit diagram and the function featur...
Page 4: ...ensure to the quality and freshness for a longer period as it can prevent oxidation mildew moth rotten and damp vacuum machine have different working environment Characteristics This machine is user friendly From the flow chart Close the machine cover air exhaustion vacuum gas filling heating sealing label printing cooling return air to the re opening of cover the whole processing is done automati...
Page 5: ...t different side so be sure to do grounding protection before use 5 Always ensure top cover is open before turning the power on Start the machine by pressing the top cover and the process start automatically For Electric cover series turn on the power supply and the top cover will automatically open By pressing the Start button which located near the control panel will start the process cycle For ...
Page 6: ...nsure all adjustment and trial is tested before production Intellingent Series 1 Turn on the power supply check through the setting shows on the panel and make sure must be shown after setting is done Otherwise operation of this machine cannot be function if the setting is not on this mode 2 Press the setting button the indicator lamp of vacuum lights to enter into the setting state of vacuum timi...
Page 7: ... separately adopting ship type three position switch installed separately on panel For this series model its temperature selection only has two gears HIGH means high temperature LOW means low temperature the middle means not heating 8 If your machine model is electric cover opening or pneumatic cover opening we will preset return air cover opening time The time relay is usually installed inside th...
Page 8: ...ling time and it will enter into the next work state automatically after the reverse timing is finished For some models this function is disable and this indication shows disable state when operation After that it moves to heating state disable 8 When heating indicator lights the equipment enters into heating work state and the panel shows the reverse timing of heating It will enter into cooling s...
Page 9: ...2 Please do not run the machine without any vacuum bag attach Otherwise the heating element will have higher wear and tear 3 Cut off the power supply and pull out external plug when no use 4 The vacuum gauge meter reading may be different due to different area 5 Please adopt suitable cooling measure when processing is done in a high temperature occasion ...
Page 10: ...not have the function of gas flush system Vacuum Chart diagram I I Note This diagram corresponds to all intelligent series model and standard model of vacuum pumps without check valve and this model of machine do not have the function of gas flush system Vacuumroom Vacuummeter Vacuumpump Gasbag V acuumroom G asbag V acuumm eter A irreliefvalve Sectionvalve V acuumpum p ...
Page 11: ...ump with check valve Vacuum circuit schematic diagram IV Note This diagram is limited for the intelligent series model with the function of gas flush system This model of machine adopts the vacuum pump without check valve Gas bag Vacuumpump Air relief valve Isolating solenoid valve Vacuummeter Charging valve Charging valve of gas bag Connected to nitrogen pot Vacuumroom ...
Page 12: ...sealing and without the function of gas flush system YVI Isolating solenoid valve YV2 Return air solenoid valve M Vacuum R Heating element KA1 KA2 KA3 separately indicate High temperature Middle temperature and Low temperature 031010 Intelligent control plate KM AC contactor ...
Page 13: ...d the function of gas flush system YVI Isolating solenoid valve YV2 Charging solenoid valve YV3 Return air solenoid valve M Vacuum pump R Heating belt KM AC contactor KA1 KA2 KA3 separately indicate High temperature Middle temperature and Low temperature 031010 Intelligent control plate ...
Page 14: ...ctric cover opening circuit of partial models combining electric schematic diagrams I and II this diagram constitutes electric cover opening machine with or without gas charging model Electrical diagram IV Note If your machine adopts three phase four wire power supply the wire connection of vacuum pump should refer to the above diagram ...
Page 15: ...nly meant for all standard models In addition for the standard model with double sealing you should only connect a heating element in parallel YV2 Isolating solenoid valve YV1 Charging solenoid valve M Vacuum pump R Heating element KM AC contactor ...
Page 16: ...hine is designed for intelligent series temperature selection switch and the temperature selection is divided into two selections YV1 Isolating solenoid valve YV2 Return air solenoid valve KM1 AC contactor of vacuum pump KM2 AC contactor of heating ...
Page 17: ...uum packing and gas flush system and the whole processing course adopts microcomputer control YV1 Isolating solenoid valve YV2 Return air solenoid valve YV3 Solenoid valve of charging nitrogen FU 4Afuse SQ DZ47 60 C16 Control transformer 220V 12V 5W Heating transformer 250W ...
Page 18: ...te This model is only suitable for double room vacuum packing machine and the temperature adjustment of this kind of machine is divided into four selections YV1 Isolating solenoid valve YV2 Return air solenoid valve SQ DZ47 60 C16 ...
Page 19: ...ened thepossiblereasonsareasfollows yAir bleed solenoid valve is not turned on yFor electric cover opening machine the cover opening motor may be damaged or pull rod is jammed 4 Airremainsinbagafterprocessingisfinished thepossiblereasonsareasfollows yWrong position resting on sealing bar Redoit yUneven sealing pressure bar presses the bag opening side so that air cannot escape 5 Abnormalsoundortri...
Page 20: ...d valve does not act and gas bag does not bulge or gas bag is damaged 2 Unevensealingveins airbubbleornotfirmsealing thereasonsareasfollows y Sealing rubber bar is unclean y Heating time is too short or temperature is too low y Sealing can t be pressed tightly caused by insufficient bulge of gas bag yAir bubble shrinks caused by insufficient cooling time y Heating sealing bar is damaged and the su...
Page 21: ... x 4450 x 170 220 Sealer Dimensions mm 260 x 8 350 x 8 480 x 8 Pump Capacity m 3 h 10 20 20 Power Consumption Kw 0 37 0 75 0 75 Voltage V 110 220 240 110 220 240 110 220 240 Frequency Hz 50 60 50 60 50 60 Production Cycle bags min 1 2 1 2 1 2 G W kg 44 73 80 N W kg 36 62 68 Shipping Dimensions mm 570 x 440 x 460 670 x 550 x 600 670 x 620 x 600 Notice Datainparenthesesindicatesheightofvacuumchamber...
Page 22: ...23 ...
Page 23: ...24 MEMO ...
Page 24: ...25 ...
Page 25: ...26 ...