CAS DLP Protocol
Variable
Descriptions
V00 Gross
Weight
(8
bytes)
V01 Tare
(8
bytes)
V02
Net Weight (8 bytes)
V03
Barcode (Net Weight) (8 bytes)
V04
Count in the Count Mode (8 bytes)
V05
Percent in the Percent Mode (8 bytes)
The weight, count and percent cannot be printed at the same time.
Values that can be accurately printed are those for [weight, count and percent].
User’s Output Message Protocol
Command (ASCII code)
Descriptions
Status
UM User
output
message
Write
The maximum length is 40 bytes. 0xFF should be put in the last byte.
20 bytes are printed in a line and the message starts from the upper left corner.
F44
Function
Enter the user output message
Display Meaning
12 - 065
Designate a character “A” equivalent to ASCII code 65 in the 12th data
00 - 032
To print out the added contents, designate ASCII code 32 to 0th data.
Set
Range
(32 ~ 255)
18 - 255
The end has to be meant by designating ASCII code 255 next to the last
data.