background image

1.4  Features

 

· 

Three functions in one: air cooler, humidifier & fan.

 

· 

Very powerful airflow: up to 2610 m 

/hr or 1540 CFM.

 

· 

Cooling area: up to 80 m 

or 880 ft 

2

 

· 

Air throw distance: 12 m or 40ft.

 

· 

Three pieces of honeycomb cooling media for optimum performance.

 

· 

Mechanical control panel.

 

· 

Mounted with castors for easy mobility.

 

· 

3 speeds: high, medium and low.

 

· 

Float valve for continuous water supply.

 

· 

60 liter water tank capacity.

 

1.5  Warning & Safety Rules

 

WARNING  ­  This  appliance  is  intended  for  use  in  an  outdoor,  domestic  or  office  or 
warehouse  environment  only.    Any  other  use  is  not  recommended  by  the  manufacturer 
and may cause fire, electrical shocks or other injury to person or property.

 

When using electrical appliances, basic safety precautions should always be followed:

 

· 

Your cooler should run on 220 Volt AC, 60 Hz current only.

 

· 

Check the household voltage to ensure it matches the appliance’s rate specification.

 

· 

Before operating the product remove it from its packaging and check it is in good condition.

 

· 

If the supply cord is damaged, it must be replaced by the manufacturer,  its service agent or 
similarly qualified persons in order to avoid a hazard.

 

· 

DO NOT operate any product with a damaged cord or plug.

 

· 

DO NOT use an extension cord with this appliance.

 

· 

DO  NOT  run  power  cord  under  carpeting,  or  cover  with  rugs  or  runners.    Arrange  the cord 
away from areas where it may be tripped over.

 

· 

Unplug the appliance during filling and cleaning.

 

· 

Always unplug the appliance from the power source before servicing or removing the unit.

 

· 

Disconnect the power supply before servicing or cleaning operation.

 

· 

Remove the power cord from the electrical receptacle by grasping and pulling on the power 
cord plug­end only, never from the cord.

 

· 

DO  NOT  use  the  product  in  areas  where  gasoline,  paint  or  other  flammable  goods  and 
objects are stored.

 

· 

When using the ‘’COOL’’ setting, please check the water indicator level to ensure it is above 
minimum  water  level.    Operation  of  this  unit  on  the  ‘’COOL’’  setting  on  or  below  minimum 
water level could result in damage to the water pump.

 

· 

DO NOT attempt repair or adjustment to any electrical or mechanical functions of the cooler.

 

· 

Verify  that  the  voltage  power  source  matches  the  appliance  electrical  specifications. 
Improper voltage will burn out the blower/fan, oscillating and/or pump motor windings and will 
void the warranty.

 

· 

DO NOT cover the air inlet or outlet on the appliance as this may cause motor damage.

 

· 

DO  NOT  insert  or  allow  objects  to  enter  any  ventilation  or  exhaust  openings  as  this  may 
damage the product and could cause an electrical shock or fire.

 

· 

DO NOT operate with media removed as this will overload and damage the motor.

 

· 

DO NOT use this appliance with any solid­state speed control device.

 

· 

DO NOT leave the appliance operating unattended for any extended period of time.

 

· 

This appliance is not intended for use by persons (including children or elderly) with reduced 
physical,  sensory  or  mental  capabilities,  or  lack  of  experience  and  knowledge,  unless  they 
have  been  given  supervision  or  instruction  concerning  use  of  the  appliance  by  a  person 
responsible for their safety.

Summary of Contents for EC60PM

Page 1: ...EC60 EVAPORATIVE AIR COOLER SERVICE MANUAL CAUTION Before servicing the unit read the Safety Precautions in this manual Only for authorized service MODEL NO EC60PM INDOOR USE ONLY...

Page 2: ...Rear Panel 2 1 2 Left Right Side Panel 2 2 How To Change Water Pump 2 2 1 Water Pump 2 2 2 Water Pump Wiring Connection 2 3 How To Change Switches 2 3 1 Switches 2 3 2 Wiring Color Connection 2 4 How...

Page 3: ...etween the jumper lead and each exposed metallic part on the equipment at all MODES except POWER OFF 4 The value should be over 1 M 1 3 Specifications MODELS ITEMS EC60 Power Supply 1 220V 60Hz Input...

Page 4: ...liance from the power source before servicing or removing the unit Disconnect the power supply before servicing or cleaning operation Remove the power cord from the electrical receptacle by grasping a...

Page 5: ...ance If the unit is damaged or it malfunctions do not continue to operate it This product is not intended for use in wet or damp locations Never locate the product where it may fall into a bathtub or...

Page 6: ...connection is made turn on the water supply to the cooler 2 The hose connection to the float valve provides an automatic method of refilling the water supply as water is evaporated 3 Whenever possible...

Page 7: ...ated weekly to maintain the integrity of the unit and to remove particles filtered from the air Once the tank is clean refill the water tank The unit is now ready to be used again MAINTAING AND CHANGI...