CABINET MAINTENANCE 

CASTERS 

Caster bearings may be equipped with Zerk grease fittings so that 
they may be easily lubricated with a grease gun. Lubricate bear-
ings at least once every six months. 

REPLACING THE DOOR GASKET 

1.  Remove the screws located under the gasket on the cabinet. 

2. 

Remove the gasket and discard.

 

3. 

Install the new gasket and replace the screws.

 

 

REVERSING THE DOOR 

Reversing the door takes about 30 minutes & requires two people. 

1.  Using a small screwdriver, pry off the hinge covers and set 

aside. Removing the covers will allow access to the inside 
hinge screws. Remove the three screws that hold each hinge 
to the cabinet.  DO NOT REMOVE THE SCREWS THAT 
HOLD THE HINGES TO THE DOOR. Remove the door, tak-
ing care not to let it fall. 

2.  Remove the door strike plate and screws adjacent to the door 

opening on the cabinet.  Reinstall door strike plate and screws 
on opposite side of the cabinet. 

3.  Screw hinges onto opposite side of the door. 

4.  With the help of another person, hold door up to the cabinet 

and attach with the screws removed in step one.  Before tight-
ening the screws, be sure the door is flush, level and square.  
Replace the hinge covers. 

WARNING: 

DO NOT perform 
these procedures 

while the cabinet is turned on 
or heated.  Turn off the power 
and wait for the cabinet to cool 
to room temperature. 

 
CAUTION:

 

Do not move cabinet 
unless door is secure-

ly closed.  Serious damage to 
hinges and door may result if 
bumped into tables, walls, or 
other equipment when the 
doors are open. 

Summary of Contents for HL8 Series

Page 1: ...NS 3 UNPACKING INSPECTION FREIGHT DAMAGE 4 INSTALLATION STARTUP 5 CONTROL PANEL LAYOUT 6 NORMAL OPERATION 7 8 FOOD HOLDING GUIDE 9 REGULAR CLEANING PROCEDURES 10 CABINET MAINTENANCE 11 WIRING DIAGRAM...

Page 2: ...rounded outlet 3 Use this appliance only for its intended purpose as described in the manual a This equipment is specifically designed to hold pre cooked food at temperature b This equipment is intend...

Page 3: ...HL8 8 Cabinets with Adjustable Universal Slides for 12 x20 Pans 18 x 26 Trays and Gastronorm Pans APPROVALS NSF ANSI 4 Features Benefits Precision engineered heat ducts with blower for even heat throu...

Page 4: ...REIGHT DAMAGE CLAIM PROCEDURE NOTE For your protection please note that equipment in this shipment was carefully inspected and packaged by skilled personnel before leaving the factory Upon acceptance...

Page 5: ...trical codes Failure could result in personal injury and proper ty damage Damage to unit due to being connected to the wrong voltage or phase is NOT covered by warranty START UP 1 Prior to use thoroug...

Page 6: ...m Press for 10 seconds to enter Alarm Toggle menu Temperature scale indicator F or C Turn knob clockwise to increase temperature set point turn counterclockwise to reduce tempera ture setpoint Press t...

Page 7: ...p After 3 seconds if setting is adjusted the newly adjusted value will be stored in the controller s memory If the cabinet power is interrupted the last value set will be the new value restored upon p...

Page 8: ...ff button while adjusting the temperature set point knob to the new desired value Due to food safety concerns the low tem perature alarm should never be set below 140 degrees F After 3 seconds the con...

Page 9: ...astries 165 F 74 C 30 Pizza uncovered 180 F 82 C 15 Pizza boxed 180 F 82 C 60 Poppers Deep Fried uncovered 190 F 88 C 25 Poultry Whole bone in 175 F 79 C 60 Poultry Cut up bone in 175 F 79 C 60 Ribs 1...

Page 10: ...in direction of grain of stainless steel Do not use on vinyl trim Stubborn Daily Any chloride free Apply with damp sponge or cloth Rub in spots and as or direction of grain of stainless steel Rinse st...

Page 11: ...T REMOVE THE SCREWS THAT HOLD THE HINGES TO THE DOOR Remove the door tak ing care not to let it fall 2 Remove the door strike plate and screws adjacent to the door opening on the cabinet Reinstall doo...

Page 12: ...ROBE 20 AMP FUSE MAX OPTIONAL FOR UNITS WITH 30 AMP PLUG OR GREATER EX CANADA BLK BLK WHT HTR1 AIR A B F1 CAP OFF YELLOW RED BLK BLK ORANGE WHT WHT YEL RED TFMR1 120VAC COM 24VAC BLK WHT BLUE YELLOW C...

Page 13: ...mit trip defective Call service technician Takes too long to get to temperature Improper voltage Call service technician to verify incoming voltage matches cabinet specifications Unit is hot but low o...

Page 14: ...CARTER HOFFMANN to be defective CARTER HOFFMANN neither makes nor assumes and does not authorize any other person to make or assume any obligation or liability in connection with its products other th...

Reviews: