Introduction.................................................................................. 3 
Serial Number.............................................................................. 3 
Location of Control Unit ............................................................... 3 
Floodlight Relay Wires................................................................. 3 
Installing Control Unit .................................................................. 3 
Power and Battery Backup .......................................................... 4 
Earth Ground ............................................................................... 4 
Trip-Test Button .......................................................................... 5 
Extra Set of Relay Contacts ........................................................ 5 
Hooking to a Security or Home Automation Panel ...................... 5 
Using Probe Fault Mode for Testing............................................ 5 
Adjusting CT-A1 (formerly FC-9( Exit Delay................................ 6 
Adjusting Sounder (Annunciator) Time........................................ 6 
Adjusting Re-Trigger Hold-Off ..................................................... 6 
Adjusting Floodlight Entry Delay Time......................................... 6 
Adjusting Floodlight Time ............................................................ 7 
Adjusting Photocell Sensitivity..................................................... 7 
Adjusting Probe Sensitivity .......................................................... 7 
Adjusting Transient Suppressor .................................................. 7 
Field Troubleshooting .................................................................. 7 
Warranty Information .................................................. Back Cover 
Merchandise Return Information ................................ Back Cover 
Technical Specifications ............................................. Back Cover 

T

ABLE

 

OF

 C

ONTENTS

 

www.GateOpenerSafety.com  |  (800) 878-7829  |  [email protected]

www.GateOpenerSafety.com  |  (800) 878-7829  |  [email protected]

Summary of Contents for CF-2C

Page 1: ...CF 2C CF 3C CONTROL UNIT ONLY Sound Lights INSTALLATION OPERATION MANUAL www GateOpenerSafety com 800 878 7829 sales GateOpenerSafety com...

Page 2: ...sting CT A1 formerly FC 9 Exit Delay 6 Adjusting Sounder Annunciator Time 6 Adjusting Re Trigger Hold Off 6 Adjusting Floodlight Entry Delay Time 6 Adjusting Floodlight Time 7 Adjusting Photocell Sens...

Page 3: ...of box when installed outside The weatherproof box must have a thermostatically controlled light bulb or heater to maintain temperatures above freezing Drastic changes in temperature cause condensatio...

Page 4: ...asonic Industries Co or G S Battery Inc The positive RED lead connected to terminal No 4 and the negative BLACK lead connected to terminal No 5 are provided for connections to the battery When an outs...

Page 5: ...UTOMATION PANEL See Figure 2 on page 2 The CF 2C has a floating dry relay contact that can be used in conjunction with any security or home automation H A system Two things will help you to have a suc...

Page 6: ...witch to hear your adjustment Adjust until the desired time is achieved ADJUSTING RE TRIGGER HOLD OFF See Figure 5 The re trigger hold off keeps the system from re triggering and thus annunciating sho...

Page 7: ...beside it Increasing the sensitivity above the factory setting is not recommended unless the probe is located in a low sensitivity area When the probe is placed in the center of a driveway that is 18...

Page 8: ...llation abuse fire and water damage electrical surges and damage to cable caused by slicing pulling tangling or improper splicing For more information visit www cartell com MERCHANDISE RETURN INFORMAT...