as shown in Figure 1C.  

Connect the black leads from the control unit to the two wires of the Romex cable with wire nuts as shown in 

Figure 1A.  

Mount the control unit to the wall over the electrical box as shown. 

P

OWER

 

AND

 B

ATTERY

 B

ACKUP

 

See Figure 2.  The control unit operates on 12 VAC or 12 VDC. Hook up the 12 VAC transformer between 

terminals No. 1 and 2 as shown in Figure 2 (NOTE: Do not connect a DC power source to terminals 1 and 2).  

A built-in battery charger will keep a 12 volt sealed lead-acid battery (not included) charged for operating the 

Sonalerts during power failure.  

NOTE:  The battery back-up is not needed for normal operation of the 

CF-2C control.

 If you choose to purchase a battery, only a sealed lead acid (starved, wet-cell) battery should 

be used.  DO NOT use a gelled-electrolyte battery. Recommended batteries are made by Yuasa Battery, Inc.; 
Gates Energy Products, Inc.; Eagle Picher Industries, Inc.; Panasonic Industries, Co.; or G.S. Battery, Inc. 

The positive (RED) lead connected to terminal No. 4 and the negative (BLACK) lead connected to terminal 

No. 5 are provided for connections to the battery.  When an outside DC power source is being used, connect 
to these terminals in place of a battery. 

Special note

:  

During initial power-up or power-down and power-up sequence, the “Exit Delay” timer is 

automatically activated.  Be patient, for the CF-2C control cannot be accessed until the “Exit Delay” 
timer times out.  It is recommended that when the control unit is first installed that the “Exit Delay” 
adjustment (potentiometer “C”) be set at minimum (fully counter-clockwise) until the system is 
operational.  (See “Adjusting FC-9 Exit Delay” on page 6.) 

E

ARTH

-G

ROUND

 

See Figure 2.  A proper earth-ground is essential. A proper earth-ground is established by using an 8 foot 

copper or copper-clad ground rod driven deeply into the earth.  

Figure 2 

CF-2C HOOK-UP 

SINGLE SWITCH 

MULTIPLE SWITCH 

Figure 1A 

Figure 1B 

Figure 1C 

Figure 1 

Back to Table of Contents 

Back to Table of Contents 

www.GateOpenerSafety.com  |  (800) 878-7829  |  [email protected]

Summary of Contents for CF-2C

Page 1: ...CF 2C CF 3C CONTROL UNIT ONLY Sound Lights INSTALLATION OPERATION MANUAL www GateOpenerSafety com 800 878 7829 sales GateOpenerSafety com...

Page 2: ...sting CT A1 formerly FC 9 Exit Delay 6 Adjusting Sounder Annunciator Time 6 Adjusting Re Trigger Hold Off 6 Adjusting Floodlight Entry Delay Time 6 Adjusting Floodlight Time 7 Adjusting Photocell Sens...

Page 3: ...of box when installed outside The weatherproof box must have a thermostatically controlled light bulb or heater to maintain temperatures above freezing Drastic changes in temperature cause condensatio...

Page 4: ...asonic Industries Co or G S Battery Inc The positive RED lead connected to terminal No 4 and the negative BLACK lead connected to terminal No 5 are provided for connections to the battery When an outs...

Page 5: ...UTOMATION PANEL See Figure 2 on page 2 The CF 2C has a floating dry relay contact that can be used in conjunction with any security or home automation H A system Two things will help you to have a suc...

Page 6: ...witch to hear your adjustment Adjust until the desired time is achieved ADJUSTING RE TRIGGER HOLD OFF See Figure 5 The re trigger hold off keeps the system from re triggering and thus annunciating sho...

Page 7: ...beside it Increasing the sensitivity above the factory setting is not recommended unless the probe is located in a low sensitivity area When the probe is placed in the center of a driveway that is 18...

Page 8: ...llation abuse fire and water damage electrical surges and damage to cable caused by slicing pulling tangling or improper splicing For more information visit www cartell com MERCHANDISE RETURN INFORMAT...

Reviews: