heat. This acts to prevent the unnecessary use of auxiliary heat. In
addition, when an outdoor sensor is attached, the system can be set
to lock out auxiliary heat for outdoor temperatures above an
installer selectable value. This will be covered under System
Configuration.
SYSTEM CONFIGURATION
Comfort Zone II -B must be configured to match the type of
equipment connected to it. In addition, there are several choices of
configuration based on how the user wants the system to operate.
Configuration is done in 2 parts. First is the setting of 8 DIP
switches on the Equipment Controller. The second is a group of
software selections made via User Interface. Follow the sequence
below for easy setup.
Configuration of the Equipment Controller is done first with the
power off. Then power is applied and the User Interface is
configured with power on.
NOTE:
A DIP switch module is oriented with switch 1 at the
bottom and switch 8 at the top. Refer to Fig. 12 for switch
orientation and labels.
Step 1—Equipment Controller Configuration
Located near bottom of Equipment Controller circuit board, there
is an 8 section DIP switch. The use of each switch is described
below. Using a pen or pencil, set each switch to its proper state.
ON is to the left and is the factory setting. OFF is to the right. Fig.
12 is a pictorial drawing of this selector switch.
Switch 1—Selects AC or HP.
ON—Selects AC.
OFF—Selects HP.
Switch 2—Selects single- or 2-speed compressor.
ON—Selects single speed.
OFF—Selects 2 speed.
Switch 3—Selects 3-stage electric heat. Equipment must include
FK or FV series fan coil with single-speed heat pump and properly
selected 3-stage electric heater.
ON—Normal 1- or 2-stage electric heat.
OFF—Special 3-stage electric heat.
Switch 4—Selects Smart Recovery in both heating and cooling.
The system starts adjusting temperature 1-1/2-hours earlier than
selected recovery time so it will arrive at new temperature at
selected time.
ON—Smart recovery.
OFF—Normal recovery.
Switch 5—Zone system address selection. When 2 zoning systems
are connected together, the second system should be set to OFF.
Fig. 11—8-Zone System Wiring Diagram
A98084
O REVERSING VALVE COOL
B REVERSING VALVE HEAT
RH HEATING TRANSFORMER
DHUM DEHUMIDIFY
DEF DEFROST
RC COOLING TRANSFORMER
SEE
FIGURES FOR
EQUIPMENT
WIRING
24 VAC ZONING
TRANSFORMER
C
RZ
8 ZONE EQUIPMENT CONTROLLER
HUM HUMIDIFY
G FAN
W2 HEAT STAGE 2
W1 HEAT STAGE 1
Y2 COMPRESSOR STAGE 2
Y1 COMPRESSOR STAGE 1
CLS7
COM7
OPN7
CLS8
HPTC
LAT
LATC
HPT
OAT
OATC
DAMPERS
8
1
CLS_
COM_
OPN_
=
=
=
CLOSE
COMMON = 24VAC FROM RZ
OPEN
COM8
OPN8
ZONE 7
DAMPER
ZONE 8
DAMPER
OUTDOOR AIR
TEMP SENSOR
LEAVING AIR
TEMP SENSOR
HEAT PUMP
TEMP SENSOR
CLS5
COM5
OPN5
CLS6
COM6
OPN6
ZONE 5
DAMPER
ZONE 6
DAMPER
CLS3
COM3
OPN3
CLS4
COM4
OPN4
ZONE 3
DAMPER
ZONE 4
DAMPER
CLS1
COM1
OPN1
CLS2
COM2
OPN2
ZONE 1
DAMPER
ZONE 2
DAMPER
JUMPER NEEDED
FOR HEAT PUMP
APPLICATIONS
DAMPER
FUSE
3A
OPTION
SWITCHES
NOTE SWITCH
#8 IS AT TOP
NA
D
C
G
NA
P
WIRELESS
RECEIVER*
D20
(LED)
DEFROST
NOTES:
*
= OPTIONAL COMPONENTS
= INSTALLING ZONE 1 REMOTE SENSOR AT OS1 AND OS1C WILL OVERRIDE
TEMPERATURE SENSOR ON USER INTERFACE
= COMMUNICATION BUS ARE IN PARALLEL WITH EACH OTHER
(EITHER CONNECTOR CAN BE USED)
†
†
V+
RS+
RS-
VG
REMOTE
SENSORS
COMMUNICATION
BUS
ZONE 3
SENSOR
ZONE 4
SENSOR
OPTIONAL
ZONE 1
SENSOR
ZONE 2
SENSOR
V+
COMMUNICATION
BUS
RS+
RS-
VG
OS1
OS1C
ZS2
ZS2C
ZS3
ZS3C
ZS4
ZS4C
ZONE 7
SENSOR
ZONE 8
SENSOR
ZONE 5
SENSOR
ZONE 6
SENSOR
ZS5
ZS5C
ZS6
ZS6C
ZS7
ZS7C
ZS8
ZS8C
V+
USER INTERFACE
RS+
RS-
VG
VG
V+
SMART SENSORS*
RS+
RS-
WHITE
RED
BLUE/YELLOW
GREEN
WHITE
RED
BLUE/YELLOW
GREEN
†
†
†
8