background image

Summary of Contents for TSTATCCNTT01-B

Page 1: ...ry stores settings indefinitely Batteries are not required The thermostat requires 24 vac both R and C terminals to be connected for proper operation The thermostat will not operate without the required connections See Table 1 This AC Model 1 stage cool 1 stage heat thermostat is to be used for single stage heating and or cooling applications only This thermostat has separate heat and cool circuit...

Page 2: ...cipators this setting is not determined by current draw There is no need to measure know or compensate for current draw There is also no droop with this thermostat Regardless of setting and number of stages both beating and cooling will control to their respective set points 1 Enter Configuration mode ff not already there See above The upper small display will indicate 01 IfOl is not displayed use...

Page 3: ... again to turn off fan The FAN icon will also turn off NOTE Some fan coils have a 90 see delay before the fan turns off COOLING OPERATION 1 Press MODE button until COOL icon is displayed 2 Press and release the DOWN arrow until cooling set point is 5 below room temperature The cool ON icon will be displayed and may flash Flashing means the equipment is going to turn on but is presently being held ...

Page 4: ...multaneously press FAN and Heating Will Not Come On UP arrow buttons to defeat timers Check for HEAT ON and 24 vac at W If present thermostat is OK and problem is with equipment or widng If not present replace thermostat Heat Cool Set Points Desired Temperatures A minimum difference of 2_is enforced between heating and cooling set points This is done by allowing one setting to push the other to ma...

Page 5: ...STAGE OR VARIABLE SPEED SINGLE SPEED THERMOSTAT FURNACE AIR CONDITIONER _ HUM _ SEE NOTE1 Fig 3_Single Speed Air Conditioner with Two Stage or Variable Speed Furnace THERMOSTAT W FIELD Rh INSTALLED JUMPER RC _ i y G I TYPICAL SINGLE SPEED FAN COIL AIR CONDITIONER W R y G C w3 E u c I SEE NOTES 2 AND 4 Fig 4_Single Speed Air Conditioner with Typical Fan Coil A01409 A01411 A01413 5 ...

Page 6: ...INGLE SPEED FAN COIL AIR CONDITIONER oHRI IJUMPER 2 Y C SEE NOTE 4 Fig 5 Single Speed Air Conditioner with Variable Speed Fan Coil THERMOSTAT BOILER T1 T2 A01410 w Rh Rc Y G C R Y G C SINGLE SPEED AIR CONDITIONER Fig 6 Single Speed Air Conditioner with Boiler A01412 6 ...

Page 7: ...E NOTE 3 Fig 7 Single Speed Air Conditioner with Single Stage Gas Furnace TH _TAT _WH T SPLICE BOX FIELb INSTALLED JUMPER Rh _ RED Rc y YEL ORN G I I C BRN SEE NOTES 3 AND 5 HEATER CONTROL BOX Fig 8 Single Speed Packaged Air Conditioner with Single Stage Electric Heat A01415 A01414 7 ...

Page 8: ...elsius F or C factory default F Fan On with W OF or ON factory default OF N A Zoning Selection OF or ON factory default OF N A Room Temperature Offset 5 to 5 factory default 0 N A Enable Auto Mode OF or ON factory default ON A01416 Copyright 2001 CARRIER Co_ 7310 W Morris St Indianapolis IN 46231 tstat27si Manufacturer reserves the right to discontinue o change at any time specifications of design...