1
−
9
T-343
CONTROL
BOX
CONTROL
PANEL
7
1. Total Time Meter
2. Engine Start Alarm (Buzzer)
3. Water Temperature Gauge
4. Auto Restart Module
5. Oil Pressure Gauge
6. Ammeter
7. Engine Start/Intake Heater
Energized Light
8. Ignition Switch
9. Battery Charger Fuse or Circuit Breaker (CB5)
10. Ground Studs
11. Circuit Breaker (CB2)
12. Starter Relay (SR)
13. Low Coolant Relay (LR)
14. Intake Heater Relay (HR)
15. Safety Relay (S)
16. Circuit Breaker (CB3)
17. Speed Control Module
Figure 1-9 Auto Restart Control Box and Panel
Table 1-2 Auto Restart Preset Values
Indicator
Preset Value
Description
Overspeed
2100 RPM
Overspeed is the point at which the unit will signal for shutdown.
Crank Disconnect
700 RPM
Crank Disconnect is the point at which the auto restart module
senses the engine has started and will disengage the starter.
Shutdown Lockout
Delay
15 seconds
The oil pressure and water temperature inputs are ignored during
this 15 second delay (after start up).
Intake Heater Delay
30 seconds
preheat
3 minutes post
heat
The delay is used during start up. The intake heater delay begins
timing after the auto restart module signal is received. During the
entire delay, the intake heater circuit will be energized, an indicator
light will be illuminated, and an alarm will sound. When the delay
expires, the unit will crank.
Crank Attempts
18 attempts
A series of six attempts with three attempts in each series for a
total of 18 attempts, refer to Table 1-3, Auto Restart Sequencing.