22
Operating Procedures
Model 632
Step 4
Place the power switch in the ON position.
Figure 31
Step 5
Press the WASH key. This will cause the sanitizing
solution in the freezing cylinder to agitate. Allow it to
agitate for five minutes.
Figure 32
Step 6
Place an empty pail beneath the door spout. Raise the
prime plug (soft serve side only).
Figure 33
Step 7
When a
steady
stream of sanitizing solution is flowing
from the prime plug opening in the bottom of the
freezer door, open the draw handle. Draw off all the
sanitizing solution.
Figure 34
Step 8
Once the sanitizer stops flowing from the door spout,
close the draw handle and press the WASH key,
cancelling the beater motor operation.
Note:
You have just sanitized the freezer.
Be sure
your hands are sanitized
before continuing these
instructions.
Step 9
Stand the air tube in the corner of the hopper.
Figure 35
Repeat steps 1 through 9
for the shake side of the
freezer.