background image

EN

ES

FR

INDOOR UNIT DISPLAY

  Hi POWER (Green)

  FILTER (Orange)

 PRE. DEF (Preheat/Defrost) 

(Orange)

  TIMER (Yellow)

  OPERATION (Green)

  RESET button

2

Press

FIX

 : Move the louver to the 

desired vertical direction.

Press

SWING

 : To continuously swing 

the louver automatically and press 
again to stop.

For horizontal direction, adjust 
manually.

AIR FLOW DIRECTION

5

Note:

 

• Do not move the louver manually by others.

  • The louver may automation positioning by some operation mode.

ONE-TOUCH

AUTOMATIC OPERATION

8

To automatically select cooling, heating, or fan only operation

 1. 

Press 

MODE

 : Select A.

 2. 

Press 

TEMP

  : Set the desired temperature.

7

Press the “ONE-TOUCH” button for fully automated operation that is 
customized to the typical consumer preferences in your region of the world. 
The customized settings control temperature air 

fl

 ow strength, air 

fl

 ow 

direction and other settings to provide you alternate contact with “ONE-
TOUCH” of the button. If you prefer other settings you can select from the 
many other operating functions of your unit.

 Press 

ONE-TOUCH

: Start the operation.

REMOTE CONTROL

6

PREPARATION BEFORE USE

3

Preparing Filters

  1. Open the air inlet grille and remove the air 

fi

 lters.

 2. 

Attach 

the 

fi

 lters. (see detail in the accessory sheet).

Loading Batteries

  1. Remove the battery cover. 
  2. Insert 2 new batteries (AAA type) 
    following the (+) and (–) positions.

Clock Setup

 1. 

Push 

CLOCK  by tip of the pencil. 

    If timer indication is 

fl

 ashing, go to the next step 2.

 2. 

Press 

ON

 or 

OFF

 : adjust the time.

 3. 

Press 

SET

 : Set the time.

1. Push and hold CHK   button on the Remote 

Control by the tip of the pencil, “00” will be 
shown on the display.

 2. 

Press 

 while pushing CHK  .

Note:

  1.  Repeat above step to reset Remote 

Control to be °F.

 

2.  Operation mode and temperature 

set will reset to initial setting after 
change the temperature unit.

 

3.  Default setting of Remote Control 

from factory is °F.

PRESET

ONE-TOUCH

QUIET

SWING

ON

CHK

OFF

CLR

SET

FIX

Hi-POWER ECO

COMFORT

SLEEP

MODE

TEMP

FAN

  Infrared signal emitter

  Start/Stop button

  Mode select button (MODE)

  Temperature button (TEMP)

  Fan speed button (FAN)

  Swing louver button 

(SWING)

  Set louver button (FIX)

  On timer button (ON)

  Off timer button (OFF)

  Sleep timer button (SLEEP)

  Setup button (SET)

  Clear button (CLR)

  Memory and Preset button 

(PRESET)

 

  One-Touch button 

 (ONE-TOUCH)

  High power button 

 (Hi-POWER)

  Economy button (ECO)

  Quiet button (QUIET)

b

  Comfort sleep button 

(COMFORT SLEEP)

  Filter reset button (FILTER)

  Clock Reset button (CLOCK)

  Check button (CHK)

REMOTE CONTROL A-B SELECTION

4

To separate using of remote control for each indoor unit in case of 2 air 
conditioners are installed adjacent to each other.

Remote Control B Setup.

  1. Press RESET button on the indoor unit to turn the air conditioner ON.
  2. Point the remote control at the indoor unit.
  3. Push and hold CHK   button on the Remote Control by the tip of the 

pencil. “00” will be shown on the display.

 4. 

Press 

MODE

 while pushing CHK  . “B” will show on the display and “00” 

    will disappear and the air conditioner will turn OFF. The Remote Control 

B is memorized.

Note:

  1.  Repeat above step to reset Remote Control back to A.

 

2.  Remote Control A have not “A” display.

 

3.  Default setting of Remote Control from 

factory is A.

SYSTEM CHARACTERISTICS

1

  1. Three-minute time delay: To protect against frequent compressor starts.
  2. Preheating operation: Warm up the unit for several minutes before 

blowing warm air.

  3. Warm air control: When the room temperature reaches the set 

temperature, the fan speed is automatically reduced and the outdoor unit 
will stop.

  4. Automatic defrosting: Fans will stop during defrost operation.
  5. Heating capacity: Heat is absorbed from outdoor and released into 

the room. When the outdoor temperature is too low, use another 
recommended heating apparatus in combination with the air conditioner.

  6. Some minor cracking sound may occur when unit operating. This is 

normal and is caused by expansion/contraction of plastic.

Note:

 Item 2 to 5 for Heating model

Air conditioner operating conditions

Temp.

Operation

Outdoor Temperature

Room

Temperature

Heating

5°F ~ 75°F (–15°C ~ 24°C)

Less than 82°F (28°C)

Cooling

14°F ~ 115°F (–10°C ~ 46°C)

70°F ~ 90°F (21°C ~ 32°C)

Dry

14°F ~ 115°F (–10°C ~ 46°C)

62°F ~ 90°F (17°C ~ 32°C)

CLR

SET

“B” Display

“00” Display

1110650133-1-EN.indd   3

1/4/10   3:50:57 PM

Summary of Contents for RAS-09LAV-UL Series

Page 1: ...ER S MANUAL ENGLISH ESPAÑOL FRANÇAIS AIR CONDITIONER SPLIT TYPE For general public use Indoor unit RAS 09 12 15 17 22LKV UL Series Outdoor unit RAS 09 12 15 17 22LAV UL Series 1110650133 1 EN indd 1 1 4 10 3 50 51 PM ...

Page 2: ... unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance CAUTION Check that the circuit breaker is installed correctly If the circuit breaker is not properly installed it may cause an electric shock To check the installation method please contact ...

Page 3: ... MODE Temperature button TEMP Fan speed button FAN Swing louver button SWING Set louver button FIX On timer button ON Off timer button OFF Sleep timer button SLEEP Setup button SET Clear button CLR Memory and Preset button PRESET One Touch button ONE TOUCH High power button Hi POWER Economy button ECO Quiet button QUIET b Comfort sleep button COMFORT SLEEP Filter reset button FILTER Clock Reset bu...

Page 4: ...windows or doors are opened The air inlet or outlet of the outdoor unit is blocked The fan speed is too low The operation mode is FAN or DRY SELF CLEANING OPERATION COOL AND DRY OPERATION ONLY 21 To protect bad smell caused by the humidity in the indoor unit 1 If the button is pressed once during Cool or Dry mode the fan will continue to run for other 30 minutes then it will turn off automatically...

Page 5: ...cas reducidas o falta de experiencia y conocimiento a no ser que reciban la autorización al uso o vigilancia de una persona responsable por su seguridad Los niños deberían ser vigilados para asegurar que no jueguen con el aparato PRECAUCIÓN Compruebe si el disyuntor está instalado correctamente de lo contrario podría producirse una descarga eléctrica Para comprobar el método de instalación por fav...

Page 6: ...or de dormir SLEEP Botón de Configuración SET Botón de borrado CLR Botón de memoria y de presintonización PRESET Botón de Único Toque ONE TOUCH Botón de alta potencia Hi POWER Botón de modo económico ECO Botón de silenciamiento QUIET b Botón de confort nocturno COMFORT SLEEP Botón de reinicio de filtro FILTER Botón de reinicio de reloj CLOCK Botón de comprobación CHK 8 Para seleccionar automáticam...

Page 7: ...cción o Ventilación 2 Pulse TEMP Ajuste la temperatura deseada Refrigeración Mín 62 F 17 C Calefacción Máx 86 F 30 C Ventilación No hay indicación de temperatura 3 Pulse FAN Seleccione AUTO LOW LOW MED MED o HIGH Para funcionamiento a velocidad súper baja del ventilador en modo silencioso excepto en modo DRY Pulse QUIET Inicia y detiene el funcionamiento Nota Bajo ciertas condiciones la operación ...

Page 8: ...e l appareil et les garde sous surveillance Les enfants doivent être surveillés afin de garantir qu ils ne jouent pas avec l appareil ATTENTION Vérifier que le disjoncteur est correctement installé Sinon il y a risque de choc électrique Pour vérifier la méthode d installation contacter le détaillant ou l installateur professionnel qui a installé l unité Si l unité est utilisée dans une pièce fermé...

Page 9: ... d un mode de fonctionnement Appuyez sur FIX Pour bloquer le volet de soufflage dans la direction souhaitée Appuyez sur SWING pour balancer en permanence les persiennes automatiquement et réappuyez pour arrêter Pour le réglage latéral effectuez celui ci manuellement Pour distinguer l utilisation de la télécommande pour chaque unité intérieure dans le cas où 2 climatiseurs sont installés à proximit...

Page 10: ... 5 fois seconde pendant 5 secondes N utilisez pas la minuterie ON et la minuterie OFF Remarque Le paramétrage par défaut du fonctionnement de redémarrage automatique est activé 15 Réglez votre mode préféré pour un usage ultérieur Le réglage est mémorisé par l appareil pour l opération suivante hormis direction du flux d air 1 Sélectionnez votre mode préféré 2 Appuyez sur and hold PRESET et mainten...

Page 11: ...1 1 3 1110650133 1 CoverBack indd 11 1 4 10 4 03 02 PM ...

Page 12: ...1110650133 1 CoverBack indd 12 1 4 10 4 03 02 PM ...

Reviews: