FN1AAF: Operation and Maintenance Manual
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
4
Airflow Adjustments
For models 006 and 015, if you desire different airflows from the
factory-set Low, Medium, and High (taps 1, 3, and 5), do these steps:
1. Move the power switch to the OFF position.
2. Unplug the unit from the wall outlet.
3. Listen to make sure the blower wheel has stopped spinning, and
loosen
the screws attaching the bottom door, but do
not
remove.
4. Remove the screws attaching the upper door and allow it to gently
swing down and rest, supported by the wire harness attached to the
front panel.
5. Locate the three blower speed tap wires (red, blue, and gray)
attached to the blower motor (
).
6. Identify the correct Motor Tap for desired airflows and connect the
wires according to
– The Red motor lead is energized when switch is set to LOW, the
Blue motor lead is energized when switch is set to MED.
NOTE:
The Blue and Gray motor leads are energized when switch is set
to HIGH. The
Gray lead should remain on Motor Tap 5
in order to
assure that red filter/obstruction indicator is properly detecting filter
condition.
A200258
Fig. 6 – Motor Taps
7. Replace the top door screws.
8. Tighten the bottom door screws.
Table 2 – Blower Configuration
Altitude Adjustments
Depending on your location, you may see up to 10% increase of
measured airflow at higher altitudes. To compensate, you can change
motor taps for alternate airflows
Troubleshooting
Before you request dealer service, check for these easily solved
problems:
• Check your main electrical panel circuit breakers or fuses if the unit
will not turn on.
• Make sure the unit is plugged in to a working 115V electrical outlet.
• Check for sufficient airflow. Filters should be clean and unobstructed.
If you need to contact your authorized dealer for troubleshooting and/or
repairs, be sure to have the model and serial numbers of your equipment
available.
Specifications
A200223
Fig. 7 – 005 Model Wiring Diagram
WARNING
!
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury or death.
Disconnect all electrical power to the unit before removing access
panels to perform any maintenance.
Switch Setting
Motor Lead
Motor Tap Options
LOW
Red
1
2
3
Switch Setting
Motor Lead
Motor Tap Options
MED
Blue
2
3
4
Switch Setting
Motor Lead
Motor Tap Options
HIGH
Gray
5
Table 3 – Electrical Specifications
005 Model
006 Model
015 Model
Voltage
115
Hertz
60
Amps
5.0
12.0
Speeds
*
*.
005 model
has a green lighted power switch only; wired to tap 5 from the
factory.
006 and 015 models
have the green lighted power switch, plus 3-speed
rotary switch; wired to taps 1, 3, and 5 from the factory. Taps 2 and 4 can be
field-wired for alternative CFMs. See
1
3
Nominal CFM
500
200 / 400 / 600
500 / 1000 / 1500
BRN
BLK - L
YEL
- N
GRN/YEL
- GND
BLU - 3
FM
TRAN
115V
FILTER
LIGHT
DIFFERENTIAL
PRESSURE
SWITCH
C
R
2
1
2a
1a
N
L1
POWER PLUG
LIGHTED
POWER SWITCH
24V