Page 1: ...T300 SCRUBBER DRYER OPERATOR MANUAL Clemas Co Unit 5 Ashchurch Business Centre Alexandra Way Tewkesbury Gloucestershire GL20 8NB Tel 01684 850777 Fax 01684 850707 Email info clemas co uk Web www clema...

Page 2: ...44 EN ISO 3741 EN ISO 13059 EN ISO 3450 EN 60335 2 72 EN according to Annex II A of the Machinery Directive Ives Franssen Operation Manager TENNANT N V Industrielaan 6 5405 AB P O Box 6 5400 AA Uden T...

Page 3: ...18 T300 WITH MEMBRANE CONTROL PANEL 18 T300 MODEL WITH PRO PANEL CONTROLS 19 MACHINE OPERATION 23 PRE OPERATION CHECK LIST 23 OPERATING MACHINE 23 WHILE OPERATING MACHINE 25 EMERGENCY SHUT OFF BUTTON...

Page 4: ...driver brush can be harmful to pacemaker wearers or medical implants This machine may be equipped with technology that automatically communicates over the cellular network If the machine will be opera...

Page 5: ...ncompatible battery chargers as this may damage battery packs and potentially cause a fire hazard Inspect charger cord regularly for damage Keep work area well ventilated Avoid contact with battery ac...

Page 6: ...battery cables before servicing machine Located on circuit board panel WARNING LABEL Spinning pad Keep hands away Located on disk scrub head model WARNING LABEL Magnetic field hazard Magnetic pad driv...

Page 7: ...ry compartment 8 Accessory rail s 9 On board battery charger cord hooks 10 Scrub head lift pedal 11 Squeegee foot pad 12 Squeegee assembly 13 Control handle 14 Control handle start bail 15 Speed contr...

Page 8: ...Panel 3 1 2 4 1 Service indicator Lights up when a machine or charger fault is detected 2 Parking brake indicator Lights up when parking brake lever is engaged To turn off indicator disengage parking...

Page 9: ...n The factory zone settings are configured with different solution flow rates down pressures and maximum scrub speeds T300 Model with Pro Panel Controls LCD Liquid Crystal Display 10 1 7 2 3 5 8 9 4 1...

Page 10: ...BLACK RED FIG 2 IMPORTANT Make sure that the machine s battery charger is properly set before charging See BATTERY CHARGER SETTINGS BATTERY PACK LIFT OUT TRAY Option Models equipped with the optional...

Page 11: ...or pad to use Contact a Tennant representative for specific recommendations Soft nylon bristle scrub brush White Recommended for cleaning coated floors without removing finish Cleans without scuffing...

Page 12: ...NSTALLING BRUSH PAD 3 Lug Disk T300e FOR SAFETY Before leaving or servicing machine stop on level surface turn off machine remove key and set parking brake if equipped 1 Step down on the scrub head li...

Page 13: ...as shown Figure 13 FIG 13 INSTALLING BRUSH PAD Insta Click Magnetic Disk FOR SAFETY Before leaving or servicing machine stop on level surface turn off machine remove key and set parking brake if equip...

Page 14: ...ng machine stop on level surface turn off machine remove key and set parking brake if equipped 1 Step down on the scrub head lift pedal to raise the scrub head off the floor Figure 19 FIG 19 2 Install...

Page 15: ...indicator Figure 27 ec H2O Scrubbing Only use cool clean water less than 21 C Do not use hot water or add conventional floor cleaning detergents An ec H2O system fault will occur if cleaning detergent...

Page 16: ...ank when refilling the solution tank 3 Adjust the mixing ratio knob according to the cleaning detergent s mixing instructions Figure 31 FIG 31 ec H2O NanoClean WATER CONDITIONING CARTRIDGE ec H2O mode...

Page 17: ...Option If model is equipped with the optional accessory clips the clips easily clip on and off the rails for additional accessory storage Figure 35 FIG 35 To install the accessory clips hook the clip...

Page 18: ...ow setting No LED No flow One LED Low flow two LED s Medium flow three LED s High flow FIG 40 4 Models equipped with Severe Environment button option Press Severe Environment button one time to dispen...

Page 19: ...PRO PANEL CONTROLS There are two types of user modes that will interface with the operator home screen Operator Mode Capable of machine operation with permissions and restrictions controlled by the s...

Page 20: ...ressure Press the symbol to decrease the down pressure FIG 49 4 Press the solution flow icon to display the solution flow scale Figure 50 Press the symbol to increase solution flow Press the symbol to...

Page 21: ...press and hold the zone number button until it prompts you to name the new zone setting Select yes to enter a new name Figure 55 By selecting no the preset name will be removed NOTE Only the superviso...

Page 22: ...n will flash yellow or red when a machine fault is detected Figure 60 FIG 60 In conjunction with a flashing service indicator icon the following fault screens will automatically pop up to indicate the...

Page 23: ...The ec H2O system will automatically turn on at start up To turn off the ec H2O system press the ec H2O switch located below the key switch Figure 65 ATTENTION During first time use and after replaci...

Page 24: ...ec H2O scrubbing press the solution flow button located on the ec H2O module Figure 71 One LED low two LED s medium and three LED s high FIG 71 10 T300e model To adjust the solution flow rate when co...

Page 25: ...and floor mounted fixtures such as pedestal sinks and other breakable items Keep the metal scrub head edge away to avoid possible damage Tile Cove FIG 74 9 When leaving the machine unattended remove t...

Page 26: ...0e FOR SAFETY When servicing machine all repairs must be performed by trained personnel HOUR METER The hour meter records the number of hours the machine has been operated Use the hour meter to perfor...

Page 27: ...cing machine stop on level surface turn off machine remove key and set parking brake if equipped 2 To drain remaining water from solution tank pull the solution hose from the accessory rail Figure 83...

Page 28: ...d problem Contact service S S S 0x0601 Severe environment detergent pump wiring connector or control board problem Contact service S S S 0x0910 Propel circuit breaker tripped Disconnect battery and re...

Page 29: ...ult Scrub control board comm fault ec H2O system comm fault Restart If fault code persists contact service ON BOARD BATTERY CHARGER SERVICE INDICATOR CODES LED Fault Code Flashing LCD Fault Code CAUSE...

Page 30: ...0x0703 0x0712 ec H2O system breaker tripped ec H2O pump breaker tripped Reset circuit breaker If trip repeats contact service ecH2O indicator solid red 0x0716 0x0727 0x0741 0x0746 ec H2O pump shorted...

Page 31: ...crub head skirt Check for damage and wear Weekly O 7 Battery cells Check electrolyte level O 6 Squeegee assembly drip trap reservoir Check clean 50 Hours O 2 Cylindrical brushes Rotate brushes Check f...

Page 32: ...repairs must be performed by trained personnel AFTER DAILY USE 1 Drain and rinse out the recovery tank Figure 86 See DRAINING TANKS FIG 86 2 T300 models Remove the debris tray and empty Figure 87 FIG...

Page 33: ...all purpose cleaner and damp cloth Figure 95 FIG 95 10 Cylindrical scrub head Remove and clean debris trough Figure 96 FIG 96 11 Severe environment option Refill the severe environment tank with a re...

Page 34: ...spect and clean the seal on the recovery tank lid Figure 104 Replace seal if damaged FIG 104 AFTER EVERY 100 HOURS OF USE If machine is equipped with the optional battery watering system check the wat...

Page 35: ...for a minimum of 15 minutes S Do not leave the batteries partially discharged for long period of time S Only charge the batteries in a well ventilated area to prevent gas build up Charge batteries in...

Page 36: ...is not equipped with charger FOR SAFETY The use of incompatible battery chargers may damage battery packs and potentially cause a fire hazard IMPORTANT NOTICE The battery charger is set to charge the...

Page 37: ...After charging batteries unplug the power supply cord and wrap cord around the cord hooks Figure 113 For models equipped with an off board charger always disconnect the AC power supply cord first befo...

Page 38: ...nnenschein 80 150 AH The factory setting dial position 0 is pre programmed to accommodate the battery type supplied with new machine After the dial is changed from the factory setting it should not be...

Page 39: ...n 1 Remove the squeegee assembly from the machine 2 Fully loosen the two outside knobs on squeegee assembly This will separate the spring loaded blade retainer from squeegee frame Figure 122 To loosen...

Page 40: ...g cartridge Figure 126 Drain recovery tank before lifting tank FIG 126 3 Disconnect the two hose connectors from the top of the cartridge by pressing the gray collars inward and pulling the connectors...

Page 41: ...teries before storing machine to prolong the life of the batteries Recharge batteries every 3 months 2 Drain and rinse recovery tank and solution tank 3 Store the machine in a dry area with squeegee a...

Page 42: ...SERVICE INDICATOR CODES Faulty charger Replace charger Machine will not propel Drive Model Propel fault has been detected See SERVICE INDICATOR CODES Circuit breaker tripped Reset circuit breaker Fau...

Page 43: ...ot completely closed Check lid for obstructions Defective seals on recovery tank lid Replaced seal Little or no solution flow Empty solution tank Refill solution tank Low solution flow rate set Increa...

Page 44: ...ransporting 21 maximum Ramp incline for loading empty tanks 21 maximum Solution flow rate T300e 1 9 L min maximum Solution flow rate T300 Low 57 L min Med 1 3 L min High 1 9 L min ec H2O solution flow...

Page 45: ...tanks 21 max Solution flow rate T300e 1 9 L min maximum Solution flow rate T300 Low 57 L min Med 1 3 L min High 1 9 L min ec H2O solution flow rate Low 45 L min Med 94 L min High 1 3 L min Brush motor...

Page 46: ...SPECIFICATIONS 46 Tennant T300e T300 03 2015 MACHINE DIMENSIONS 1095 mm 772 mm SINGLE DISK MODEL 1302 mm 43 cm Model 1372 mm 50 cm Model 508 mm 43 cm Model 559 mm 50 cm Model...

Page 47: ...SPECIFICATIONS Tennant T300e T300 03 2015 47 1095 mm 772 mm DUAL DISK MODEL 1314 mm 660 mm...

Page 48: ...SPECIFICATIONS 48 Tennant T300e T300 03 2015 1095 mm 772 mm CYLINDRICAL BRUSH MODEL 1283 mm 635 mm...

Page 49: ...SPECIFICATIONS Tennant T300e T300 03 2015 49 1095 mm 772 mm ORBITAL PAD MODEL 1245 mm 521 mm...

Page 50: ...SPECIFICATIONS 50 Tennant T300e T300 03 2015...

Page 51: ...elow 1 Park the machine on a level surface and turn the key to off O position 2 Press and hold the Down Pressure button while turning the key on Release button when the far right battery discharge ind...

Page 52: ...e factory assigned supervisor login number or your saved personalized supervisor login number to access the operator home screen 2 Press the settings button located on the home screen Figure 136 FIG 1...

Page 53: ...be any combination of numbers ranging from 3 to 8 digits long FIG 143 6 Now select the controls that the new user should have access to use Figure 144 Green represents unlocked controls and gray repr...

Page 54: ...profiles Figure 149 For example to edit any user profile settings including the factory assigned default supervisor login number press the Edit Profile button FIG 149 To change the factory assigned de...

Page 55: ...sired default user by pressing the Operator or Supervisor button Figure 154 FIG 154 d Select a pre assigned user profile In this example operator profile JOHN is selected Figure 155 Turn the key off t...