background image

12

OPERATION  TIPS

The following events may occur during normal operation.
1.  

Protection of the air conditioner.

         

Compressor protection

         The compressor can't restart for 3~4 minutes after it stops.
         

Anti-cold air (Cooling and heating  models only)

         The unit is designed not to blow cold air on HEAT mode, when the indoor heat exchanger is in 
         one of the following three situations and the set temperature has not been reached.
         A)  When heating has just starting.
         B)  Defrosting.
         C)  Low temperature heating.
         The indoor or outdoor fan stop running when defrosting (Cooling and heating models only).
         

Defrosting (Cooling and heating models only)

         Frost may be generated on the outdoor unit during heat cycle when outdoor temperature is low 
         and humidity is high resulting in lower heating efficiency of the air conditioner. 
         During this condition air conditioner will stop heating operation and start defrosting automatically.
         The time to defrost may vary from 4 to 10 minutes according to the outdoor temperature and 
          the amount of frost build up on the outdoor unit.

2. 

A white mist coming out from the indoor unit

         A white mist may generate due to a large temperature difference between air inlet and air outlet 
         on COOL mode in an indoor environment that has a high relative humidity.
         A white mist may generate due to moisture generated from defrosting process  when the  air 
         conditioner restarts in HEAT mode operation after defrosting.

3. 

Low noise of the air conditioner

         You may hear a low hissing sound when the compressor is running or has just  stopped running. 
         This sound is the sound of the refrigerant flowing or coming to  a stop.
         You can also hear a low "squeak" sound when the compressor is running or has just stopped 
         running. This is caused by heat expansion and cold contraction of the plastic parts in the unit 
         when the temperature is changing.
         A noise may be heard due to louver restoring to its original position when power is first turned on.

4. 

Dust is blown out from the indoor unit.

    This is a normal condition when the air conditioner has not been used for a long time or during first 
    use of the unit.

5. 

A peculiar smell comes out from the indoor unit.

    This is caused by the indoor unit giving off smells permeated from building material, from furniture, 
    or smoke. 

6. 

The air conditioner turns to FAN only mode from COOL or HEAT (For cooling and 

     heating models only) mode.

    When indoor temperature reaches the temperature setting on air conditioner, the  compressor will 
    stop automatically, and the air conditioner turns to FAN only mode.  The compressor will start again 
    when the indoor temperature rises on COOL mode or falls on HEAT mode (For cooling and heating 
    models only) to the set point.

Summary of Contents for LUVH025N

Page 1: ...LUVH025N LUVH035N LUVH045N LUVH055N LUVH065N LUVH075N...

Page 2: ...ord is to be replaced replacement work shall be performed by authorised personnel only Installation work must be performed in accordance with the national wiring standards by authorised personnel only...

Page 3: ...f such waste separately for special treatment is necessary It is prohibited to dispose of this appliance in domestic household waste Wild disposal of waste in forests and landscapes endangers your hea...

Page 4: ...ay cause fire and electric shock It may cause explosion fire and burns It may cause electric shock or fire due to heat generation It may cause electric shock It may cause failure of machine or electri...

Page 5: ...cond itioner to preserve preci sion devices food pets plants and art objects It may cause deterioration of quality etc It may cause failure of product or fire Do not use for special purposes Turn off...

Page 6: ...8 Air filter 9 Manual control button 10 Remote controller holder 11 Remote controller 12 Connecting pipe 13 Drain hose 14 15 Connective pipe 16 Stop valve Connecting cable Indoor unit Outdoor unit 6 5...

Page 7: ...eating operation 1 2 2 3 4 A Usually it displays the temperature settings When change the setting temperature this indicator begins to flash and stops 20 seconds later B It displays the room temperatu...

Page 8: ...ance will be achieved within these operating temperature Suggestion For the unit adopts an Electric Heater when the outside ambient temperature is O below 0 C we strongly recommend you to keep the mac...

Page 9: ...st be disconnected For some models the vertical louver can be adjusted by using the remote controller Please refer to the REMOTE CONTROLLER OPERATION MANUAL for details Do not operate the air conditio...

Page 10: ...ontrolled under dry operation During the dry operation if the room temperature is lower O than 10 C the compressor stops operation and restarts O until the room temperature is above 12 C To achieve op...

Page 11: ...cleaning To clean wipe with a soft dry cloth Do not use bleach or abrasives NOTE Supply power must be disconnectd before cleaning the indoor unit Filter Handle A clogged air filter reduces the coolin...

Page 12: ...o water can destroy the insulation leading to possible electric shock When cleaning the unit first make sure that the power and circuit breaker are turned off Caution 4 Remove the A Plasma Dust Collec...

Page 13: ...high relative humidity A white mist may generate due to moisture generated from defrosting process when the air conditioner restarts in HEAT mode operation after defrosting 3 Low noise of the air cond...

Page 14: ...If a comfortable temperature can t be achieved by the air conditioner we suggest you use a supplementary heating device 9 Auto restart function Power failure during operation will stop the unit compl...

Page 15: ...ck that plug is securely in wall receptacle Replace the fuse Replace the battery Wait or cancel timer setting Set temperature correctly For detailed method please refer to Using remote control section...

Page 16: ...CS527 U 2020323A7020 The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details...

Reviews: