 8

OPERATING  INSTRUCTIONS

Airflow direction control

Range

Range

Vertical 
louver
(three places)

   Adjust the air flow direction properly otherwise, it 
   might cause discomfort or  cause uneven room 
   temperatures.
   Adjust the horizontal louver using the remote 
   controller.
   Adjust the vertical louver manually.

  

To set the vertical air flow(Up--Down) direction

   

Perform this function while the unit is in operation.

   Use the remote controller to adjust the air flow 
   direction. The horizontal louver can be moved at 

O

   a range of 6  for each press, or swing up and down
    automatically. Please refer to the   REMOTE 
    CONTROLLER OPERATION MANUAL    for details. 
   

   

   

To set the horizontal air flow direction (left - right)

Move the vertical louver manually to adjust the air flow 
in the direction you prefer.

IMPORTANT

: Before adjusting the vertical louvers, the 

supply power must be disconnected.
For some models, the vertical louver can be adjusted
by using the remote controller. Please refer to the
  REMOTE CONTROLLER OPERATION MANUAL    
for details. 

    

Do not operate the air conditioner for long periods 

 the 

air flow direction set downward in cooling or dehumidifying
 mode. 
Otherwise, condensation may occur on the surface of the 
horizontal louver causing moisture to drop on to the floor or 
on furnishings.
Do not move the horizontal louver manually unless it is 
necessary. Always use the remote controller. 
When the air conditioner is started immediately after it was 
stopped, the horizontal louver might not move for 
approximately 10 seconds.
Open angle of the horizontal louver should not be set too 
small, as COOLING or HEATING performance may be 
impaired due to too restricted air flow area.
Do not operate unit with horizontal louver in closed position.
When the air conditioner is connected to power (initial 
power), the horizontal louver may generate a sound for 10 
seconds, this is a normal operation.

with

CAUTION

!

,,

,,

,,

,,

Summary of Contents for LUVH025N

Page 1: ...LUVH025N LUVH035N LUVH045N LUVH055N LUVH065N LUVH075N...

Page 2: ...ord is to be replaced replacement work shall be performed by authorised personnel only Installation work must be performed in accordance with the national wiring standards by authorised personnel only...

Page 3: ...f such waste separately for special treatment is necessary It is prohibited to dispose of this appliance in domestic household waste Wild disposal of waste in forests and landscapes endangers your hea...

Page 4: ...ay cause fire and electric shock It may cause explosion fire and burns It may cause electric shock or fire due to heat generation It may cause electric shock It may cause failure of machine or electri...

Page 5: ...cond itioner to preserve preci sion devices food pets plants and art objects It may cause deterioration of quality etc It may cause failure of product or fire Do not use for special purposes Turn off...

Page 6: ...8 Air filter 9 Manual control button 10 Remote controller holder 11 Remote controller 12 Connecting pipe 13 Drain hose 14 15 Connective pipe 16 Stop valve Connecting cable Indoor unit Outdoor unit 6 5...

Page 7: ...eating operation 1 2 2 3 4 A Usually it displays the temperature settings When change the setting temperature this indicator begins to flash and stops 20 seconds later B It displays the room temperatu...

Page 8: ...ance will be achieved within these operating temperature Suggestion For the unit adopts an Electric Heater when the outside ambient temperature is O below 0 C we strongly recommend you to keep the mac...

Page 9: ...st be disconnected For some models the vertical louver can be adjusted by using the remote controller Please refer to the REMOTE CONTROLLER OPERATION MANUAL for details Do not operate the air conditio...

Page 10: ...ontrolled under dry operation During the dry operation if the room temperature is lower O than 10 C the compressor stops operation and restarts O until the room temperature is above 12 C To achieve op...

Page 11: ...cleaning To clean wipe with a soft dry cloth Do not use bleach or abrasives NOTE Supply power must be disconnectd before cleaning the indoor unit Filter Handle A clogged air filter reduces the coolin...

Page 12: ...o water can destroy the insulation leading to possible electric shock When cleaning the unit first make sure that the power and circuit breaker are turned off Caution 4 Remove the A Plasma Dust Collec...

Page 13: ...high relative humidity A white mist may generate due to moisture generated from defrosting process when the air conditioner restarts in HEAT mode operation after defrosting 3 Low noise of the air cond...

Page 14: ...If a comfortable temperature can t be achieved by the air conditioner we suggest you use a supplementary heating device 9 Auto restart function Power failure during operation will stop the unit compl...

Page 15: ...ck that plug is securely in wall receptacle Replace the fuse Replace the battery Wait or cancel timer setting Set temperature correctly For detailed method please refer to Using remote control section...

Page 16: ...CS527 U 2020323A7020 The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details...

Reviews: