background image

7

INSTALLATION

Installation precautions for the wired remote controller:

S

Do not install in a location near heavy oil, vapor or sulfurated gas otherwise this product

will deform which will lead to a system malfunction.

S

Do not install the unit in a location near flammable gas leaks. Once flammable gases leak

and are left near the wired controller, a fire may occur. Do not operate with wet hands. Do

not allow water to enter the wired controller otherwise an electric shock may occur.

S

The wiring should conform to the wired controller current otherwise electric leakage or

heating may occur which may result in fire. Use the correct cables for wiring. No external

force may be applied to the terminal otherwise wire cuts and heating may occur and result

in a fire.

S

This manual contains the installation method for the wired controller. Refer to the wiring

diagram in this manual to connect the wired controller to the indoor unit.

S

The wired controller operates in a low voltage loop circuit. Do not connect the 208

230V

power directly to the thermostat. Do not wire this type of wire in the same loop. The wiring

clearance between the configured tubes should maintain a range of 12 

 20 inches (305

508mm) or more.

S

The wired controller shielded wire must be well grounded.

S

The wired controller connective cable should not be longer than 66 feet (20 meters).

This manual provides a detailed description of the precautions that should be taken during operation.

To ensure correct service of the wired controller, read this manual carefully before using the unit. After

reading this manual thoroughly, keep it for future reference.

Summary of Contents for KSACN0101AAA

Page 1: ...KSACN0101AAA Wired Remote Controller with Timer Function For Ductless Systems Installation Instructions NOTE Read the entire instruction manual before starting the installation...

Page 2: ...ert symbol When you see this symbol on the unit and in instructions or manuals pay attention to the potential for personal injury Understand these signal words DANGER WARNING and CAUTION These words a...

Page 3: ...shock or fire Re installation must be performed by authorized professionals Non compliance may lead to electric shock or fire CAUTION EQUIPMENT DAMAGE HAZARD Failure to follow this warning may result...

Page 4: ...dification or installation of this kit be sure the main electrical disconnect is in the OFF position Ensure power is disconnected to the fan coil unit On some systems both the fan coil and the outdoor...

Page 5: ...9DBMA 40MBQB12D 3 619REQ012DBMA 40MBQB18D 3 619REQ018DBMA 40MBQB24D 3 619REQ024DBMA 40MBQB36D 3 619REQ036DBMA 40MBQB48D 3 619REQ048DBMA FLOOR CONSOLE 40MBQB09F 3 619REQ009FBMA 40MBQB12F 3 619REQ012FBM...

Page 6: ...3 40MKQB34C 3 40MKQB34C 3 40MKQB34C 3 40MKQB34C 3 40MKQB34C 3 UNDERCEILING FLOOR CONSOLE 40MKCB18F 3 40MKCB34F 3 40MKCB34F 3 40MKCB34F 3 40MKCB34F 3 40MKCB34F 3 40MKCB54F 3 40MKCB54F 3 40MKCB54F 3 40...

Page 7: ...wire cuts and heating may occur and result in a fire S This manual contains the installation method for the wired controller Refer to the wiring diagram in this manual to connect the wired controller...

Page 8: ...rews 3 M4X20 for mounting on the wall 4 Wall plugs 3 For wall mounting 5 Screws 2 M4X25 for mounting on the wall 6 Plastic screw bars 2 For fixing on the switch box 7 The connective wires group 1 24AW...

Page 9: ...9 DIMENSIONS 4 7in 120mm 4 7in 120mm 83in 21mm 52in 13 1mm 2inches 51mm 77in 19 5mm 3 37inches 85 5mm 1 9inches 50mm CONNECTION DIAGRAM...

Page 10: ...the male joint of the wires group leads from the wired controller 3 Remove the upper part of the wired controller 4 Insert a slot screwdriver into the slots of the lower part of the wired controller...

Page 11: ...red controller 6 For exposed mounting fasten the back plate on the wall with the 3 screws M4x20 and plugs 7 For flush mounting fasten the back plate of the switch box with 2 screws M4x25 and then fast...

Page 12: ...Place on a flat surface Be careful not to distort the back plate of the wired controller by over tightening the mounting screws 8 For exposed mounting there are four outlet positions and three require...

Page 13: ...13 0 75 in 20mm...

Page 14: ...pper part of the wired controller 10 After adjusting the upper case buckle the upper case Avoid clamping the wiring during installation NOTE The pictures in this manual are for illustration purposes o...

Reviews: