background image

6

CARRIER ACCESSORIES

ACCESSORIES

ELECTRONIC AIR

CLEANER (EAC)

Model EACB

AIR PURIFIER

Models GAPAAXCC1625, GAPAAXCC2025

MECHANICAL AIR

CLEANER

Models EZXCAB, FILCAB

HUMIDIFIER

Model HUM

HEAT RECOVERY

VENTILATOR

Model HRV

ENERGY

RECOVERY

VENTILATOR

Model ERV

UV LIGHTS

Model UVL

THERMOSTAT ---

NON---

PROGRAMMABLE

For use with 1---speed Air Conditioner --- deg. F/C, Auto Changeover --- TP---NAC, TC---NAC
For use with 1---speed Heat Pump --- deg. F/C, Auto Changeover --- TP---NHP, TC---NHP*
For use with 2---speed Air Conditioner --- deg. F/C, Auto Changeover --- TP---NRH*
For use with multi---use / stage configurations --- deg. F/C, Auto Changeover/Temperature and Humidity

Control --- TP---PRH

{

THERMOSTAT ---

PROGRAMMABLE

For use with 1---speed Air Conditioner --- deg. F/C, Auto Changeover, 7---Day Programmable --- TP---PAC
For use with 1---speed Heat Pump --- deg. F/C, Auto Changeover, 7---Day Programmable ---

TP---PHP*
For use with 2---speed Air Conditioner --- deg. F/C, Auto Changeover, 7---Day Programmable --- TP---PRH*
For use with 1---speed Air Conditioner --- deg. F/C, 5---2 Day Programmable --- TP---PAC
For use with multi---stage applications --- deg. F/C, Auto Changeover, 7---Day Programmable --- TC---PHP

}

For multi---use / stage configurations --- deg. F/C, Auto Changeover, 7---Day Programmable/Temperature

and Humidity Control ---TP---PRH

{

ZONING CONTROL

Comfort Series™ Three---Zone Kit --- ZONECC3ZAC01, ZONECC3ZHP01
2---Performance™ Series ComfortZone™ Zoning/Temperature and Humidity Control --- ZONECC2KIT01---B
4---Performance™ Series ComfortZone™ Zoning/Temperature and Humidity Control --- ZONECC4KIT01---B
8---Performance™ Series ComfortZone™ Zoning/Temperature and Humidity Control --- ZONECC8KIT01---B

TYPICAL WIRING SCHEMATIC

115-V FIELD-

SUPPLIED

DISCONNECT

AUXILIARY

J-BOX

24-V

TERMINAL

BLOCK

THREE-WIRE

HEATING-ONLY

FIVE WIRE

NOTE 1

NOTE 2

FIELD-SUPPLIED

DISCONNECT

CONDENSING

UNIT

TWO

WIRE

FURNACE

C

O

N

T

R

O

L

R

G

COM

W

C

R

G

Y

GND

GND

FIELD 24-V WIRING

FIELD 115-, 208/230-, 460-V WIRING

FACTORY 24-V WIRING

FACTORY 115-V WIRING

208/230- OR

460-V

THREE

PHASE

208/230-V

SINGLE

PHASE

BLOWER DOOR SWITCH

WHT

BLK

WHT

BLK

NOTES:

Connect Y-terminal in furnace as shown for proper blower operation.

Some thermostats require a "C" terminal connection as shown.

If any of the original wire, as supplied, must be replaced, use

same type or equivalent wire.

W

Y/Y2

GND

THERMOSTAT

TERMINALS

1.

2.

3.

*Model HP and 2S thermostat must be field converted to air conditioner operation.

{

Thermidistat

t

Contro

l

control can be configured for multiple use and staging. It must be configured for each specific application.

}

Dual Fuel thermostat is used with furnace and heat pump application.

A99440

58PH

A

Summary of Contents for Infinity GAPAAXCC1625

Page 1: ...in Low NOx Air Quality Management Districts STANDARD FEATURES S ECM Blower Motor included S QuieTecht noise reduction system S SmartEvapt Humidity control when using a Thermidistatt Control S ComfortFant adjustable constant fan speed from the thermostat S Microprocessor based control center Enhanced diagnostics with LED and reflective sight glass Stores fault codes during power outages Adjustable ...

Page 2: ...LBOW MAIN LIMIT SWITCH BEHIND GAS VALVE BLOCKED VENT SWITCH FLAME SENSOR GAS MANIFOLD GAS BURNER BLOWER AND MOTOR MANUAL RESET LIMIT SWITCHES CAPACITOR POWER CHOKE A10314 NOTE The 58PHA PHX Furnaces are factory shipped for use with natural gas These furnaces can be field converted for propane gas with a factory authorized and listed accessory conversion kit 58PHA ...

Page 3: ...8 219 219 5 1 2 5 1 2 140 3 140 3 8 7 16 8 7 16 213 5 213 5 FRONT OF CASING FRONT OF CASING TOP OF CASING TOP OF CASING 6 1 6 1 155 7 155 7 2 1 16 2 1 16 51 6 51 6 5 1 5 1 130 5 130 5 1 7 1 7 43 5 43 5 Ø7 8 Ø7 8 22 2 22 2 ACCESSORY 2 ACCESSORY 2 AIR FLOW AIR FLOW AIR FLOW AIR FLOW BOTTOM RETURN BOTTOM RETURN WIDTH WIDTH AIR FLOW AIR FLOW KNOCK OUTS FOR KNOCK OUTS FOR VENTING 5 VENTING 5 PLACES PLA...

Page 4: ...ntrol SPST Heating Blower Control Solid State Time Operation Burners Monoport 2 3 4 5 6 Gas Connection Size 1 2 in NPT GAS CONTROLS Gas Valve Redundant Mfr White Rodgers Min inlet pressure In W C 4 5 Natural Gas Max inlet pressure In W C 13 6 Natural Gas Ignition Device Hot Surface Factory installed orifice Size 43 BLOWER DATA Direct Drive Motor HP ECM 1 2 3 4 3 4 1 1 Motor Full Load Amps 6 8 8 8 ...

Page 5: ...GAWF1406UFR X X KGAWF1506UFR X Flue Extension KGAFE0112UPH X X X X X Combustible Floor Base KGASB0201ALL X X X X X Downflow Vent Guard KGBVG0101DFG X X X X X Vent Extension Kit KGAVE0101DNH X X X X X Chimney Adapter Kit KGACA02014FC X X X X Chimney Adapter Kit KGACA02015FC X Natural to Propane Conversion Kit KGBNP50011SP X X X X X Propane to Natural Conversion Kit KGBPN42011SP X X X X X Label Kit ...

Page 6: ... Temperature and Humidity Control TP PRH ZONING CONTROL Comfort Series Three Zone Kit ZONECC3ZAC01 ZONECC3ZHP01 2 Performance Series ComfortZone Zoning Temperature and Humidity Control ZONECC2KIT01 B 4 Performance Series ComfortZone Zoning Temperature and Humidity Control ZONECC4KIT01 B 8 Performance Series ComfortZone Zoning Temperature and Humidity Control ZONECC8KIT01 B TYPICAL WIRING SCHEMATIC...

Page 7: ...ediately after exiting the furnace except when Downflow Vent Guard is used in downflow position 4 Type B vent where required refer to Note 1 5 4 in 102 mm single wall vent must be used inside furnace casing and the Downflow Vent Guard Kit 6 Accessory Downflow Vent Guard Kit required in downflow installations with bottom vent configuration 7 Chimney Adapter Kit required for exterior masonry chimney...

Page 8: ... 8 9 SEE NOTES 1 2 4 7 8 9 SEE NOTES 1 2 4 5 7 8 9 SEE NOTES 1 2 4 5 7 8 9 SEE NOTES 1 2 4 5 7 8 9 HORIZONTAL RIGHT HORIZONTAL RIGHT HORIZONTAL RIGHT HORIZONTAL LEFT HORIZONTAL LEFT HORIZONTAL LEFT HORIZONTAL LEFT A02069 A02068 A02070 A02064 A02066 A02065 A02067 58PHA ...

Page 9: ...00 Orange 2 1225 1160 1110 1060 1010 950 895 830 770 710 Red 1 1100 1030 960 875 805 730 645 570 505 425 110 20 Gray 5 2255 2205 2150 2100 2040 1985 1920 1835 1735 1615 Yellow 4 1600 1525 1465 1400 1335 1275 1210 1150 1080 1015 Blue 3 1945 1890 1830 1770 1715 1655 1600 1545 1480 1430 Orange 2 1420 1340 1280 1200 1140 1065 1005 925 865 790 Red 1 1280 1205 1140 1055 990 910 840 760 695 630 135 20 Gr...

Page 10: ... A10269 Always Ask For Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program For verification of certification for individual products go to www ahridirectory org 58PHA ...

Page 11: ...ve reusable type filters Filter shall be _______ in x _______in mm An accessory high efficiency Media Filter is available as an option _______________ Media Filter Casing Casing shall be of 030 in 76 mm thickness minimum pre painted steel Inducer Motor Inducer motor shall be soft mounted to reduce vibration transmission Draft Safeguard Switch Draft Safeguard Switch blocked vent safeguard shall be ...

Page 12: ...p S 7310 W Morris St S Indianapolis IN 46231 Edition Date 08 13 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Catalog No 58PHA 08PD Replaces 58PHA 07PD 58PHA ...