SPECIFICATIONS
UNIT SIZE
045--08
070--16
090--16
110--20
135--20
RATINGS AND PERFORMANCE
Input Btuh*
58PHX Upflow; all 58PHA
44,000
66,000
88,000
110,000
132,000
Nonweatherized ICS
58PHX Downflow/Horizontal
42,000
63,000
84,000
105,000
126,000
Output Capacity (Btuh)†
58PHX Upflow; all 58PHA
36,000
53,000
72,000
90.000
107.000
Nonweatherized ICS
58PHX Downflow/Horizontal
34,000
51,000
69,000
86,000
102,000
AFUE†
80.0
80.0
80.0
80.0
80.0
Certified Temperature Rise Range --- ° F (° C)
30-60
(17---33)
25---55
(14---31)
35---65
(19---36)
30-60
(17---33)
40-70
(22---39)
Certified External Static Pressure
Heat/Cool
0.10/0.50
0.12/0.50
0.15/0.50
0.20/0.50
0.20/0.50
Airflow CFM‡
Heating
735
1230
1345
1890
1865
Cooling
1035
1460
1665
2040
2070
ELECTRICAL
Unit Volts---Hertz---Phase
115-60-1
Operating Voltage Range
Min-Max
104-127
Maximum Unit Amps
8.1
10.8
11.4
14.2
14.2
Maximum Wire Length (Measure one way in Ft (M)
34 (10)
26 (8)
25 (7)
31 (9)
31 (9)
Minimum Wire Size
14
12
Maximum Fuse or Ckt Bkr Size (Amps)**
15
20
Transformer (24v)
40va
External Control
Heating
12va
Power Available
Cooling
35va
Air Conditioning Blower Relay
Standard
CONTROLS
Limit Control
SPST
Heating Blower Control
Solid-State Time Operation
Burners (Monoport)
2
3
4
5
6
Gas Connection Size
1/2-in. NPT
GAS CONTROLS
Gas Valve (Redundant)
Mfr.
White-Rodgers
Min. inlet pressure (In. W.C.)
4.5 (Natural Gas)
Max. inlet pressure (In. W.C.)
13.6 (Natural Gas)
Ignition Device
Hot Surface
Factory-installed orifice
Size 43
BLOWER DATA
Direct-Drive Motor HP (ECM)
1/2
3/4
3/4
1
1
Motor Full Load Amps
6.8
8.8
8.8
11.5
11.5
RPM (Nominal)-Speeds
1050---5
Blower Wheel Diameter x Width --- In. (mm)
10 x 6
(254 x 152)
11 x 8
(279 x 203)
10 x 10
(254 x 254)
11 x 11
(279 x 279)
11 x 11
(279 x 279)
*
Gas input ratings are certified for elevations to 2000 ft. (610 M). In USA, for elevations above 2000 ft. (610 M), reduce ratings 4 percent for each 1000 ft. (305
M) above sea level. Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1---2012 Table F.4 or furnace installation instructions.
†
Capacity in accordance with U.S. Government DOE test procedures.
‡
Airflow shown is for bottom only return-air supply for the as-shipped speed tap. For air delivery above 1800 CFM, see Air Delivery table for other options. A
filter is required for each return-air supply. An airflow reduction of up to 7 percent may occur when using the factory-specified 4-5/16 in. wide, high efficiency
media filter.
** Time---delay type is recommended.
ICS Isolated Combustion System
58PH
A