Comfort Heat

On the coldest days of the year, the Infinity 96 Furnace has the
capacity to heat your home. On moderate days when less heat is

required, this furnace will regulate itself to a lower

capacity—providing a comfortable home and minimizing
operating costs.
The patented algorithm adjusts the low--heat operating time to
match the indoor conditions.

Reliable Heat Exchanger Design

The primary heat exchanger is made of aluminized steel for

corrosion resistance. The patented Serpentuff

t

condensing heat

exchanger cells are laminated with polypropylene for greater

resistance to corrosion and epoxy coated externally to prevent
oxidation. This breakthrough in heating technology helps extend

the life of the furnace for years of dependable performance. The
heat exchanger is positioned in the furnace to extract additional

heat. Stainless steel 409 heat exchanger assembly has better

corrosion resistance in natural gas and propane applications.

Power Heat

t

Igniter

Carrier’s unique SiN igniter is not only physically robust but it is

also electrically robust. It is capable of running at line voltage and
does not require complex voltage regulators as do other brands.

This unique feature further enhances the reliability of Infinity 96

gas furnace and continues Carrier’s tradition of technology
leadership and innovation in providing a reliable and durable

product.

ComfortFan

t

Improves comfort all year long by allowing you to select the

continuous fan speed right at the thermostat.

SmartEvap

t

Allows your system to reduce summertime humidity levels by
nearly 10% cover standard systems.

Media Filter Cabinet

Enhanced indoor air quality in your home is made easier with our
media filter cabinet—a standard accessory on all deluxe furnaces.

When installed as a part of your system, this cabinet allows for

easy and convenient addition of a Carrier high--efficiency air
filter.

ComfortHeat

t

Control Center

The microprocessor control center features state--of--the--art
combustion, temperature, and airflow control to maximize

comfort while operating at peak efficiency.
Combustion control is obtained by taking the appropriate inducer
motor RPM readings when the low--and high--fire pressure

switches are made. Using this information, the microprocessor
main--information, the microprocessor maintains a consistent

air--to--fuel ratio independent of vent sizing and conditions.
The first cycle after power reset provides 16 minutes of low heat

before switching to high heat unless the room thermostat has been

satisfied. Subsequent thermostat cycles provide anywhere from 0
to 16 minutes of low heat depending on the length of the

previous thermostat cycle.
Airflow control is accomplished by using a technique involving

the microprocessor and blower motor. The static load on the air

delivery system is measured each heating cycle. The
microprocessor then uses this information to deliver correct

airflow independent of variations in system restrictions. (For
example, dirty filter or zone damper changes during a cycle.)
A special dehumidification function allows direct input from a

thermidistat or humidistat. This input adjusts system airflow for
greater humidity removal and increased cooling comfort during

summer months.

Warranty

The Infinity 96 heat exchangers come with a Limited Warranty

for lifetime of original owner in single family residence; 20 years

in other residential and commercial applications. Five--year
limited warranty on entire units. Contact your dealer for details.

Direct Venting

The Infinity 96 should be installed as a 2--pipe (direct vent)
furnace.

Electronic Variable--Speed Motors

ECM Motors (Electronically Commutated Motor) provide

variable--speed operation to optimize comfort levels in the home
year round. They are also more economical to operate than

standard motors.

Sealed Combustion System

Infinity 96 brings in combustion air from outside the furnace,

which results in especially quiet operation.

Insulation

Foil--faced insulation in heat exchanger section of the casing
minimizes heat loss.

Insulated Blower Compartment

The acoustical insulation reduces air and motor noise for quiet
operation.

Monoport Burners

The burners are finely turned for smooth, quiet combustion and

economical operation.

Bottom Closure

Factory--installed for side return; easily removable for bottom

return.

Blower Access Panel Switch

Automatically shuts off 115--V power to furnace whenever
blower access panel is opened.

Quality Registration

The Infinity 96 is engineered and manufactured under an ISO
9001 registered quality system.

Certifications

The Infinity 96, Model 58UVB units are CSA (AGA and CGA)

design certified for use with natural and propane gases. The
furnace is factory--shipped for use with natural gas. A CSA listed

gas conversion kit is required to convert furnace for use with
propane gas. The efficiency is GAMA efficiency rating certified.

The Infinity 96 meets California Air Quality Management District
emission requirements.

58U

VB

Summary of Contents for Infinity 96 58UVB

Page 1: ... pipe only The Infinity 96 is not approved for installation in mobile homes recreational vehicles or outdoor use The variable speed makes the Infinity 96 ideal for use with split system cooling including 2 stage units A Carrier electronic air cleaner humidifier Thermidistatt comfort ventilator and Comfort Zonet II will provide year round comfort and efficiency Designed for durability comfort and r...

Page 2: ... The first cycle after power reset provides 16 minutes of low heat before switching to high heat unless the room thermostat has been satisfied Subsequent thermostat cycles provide anywhere from 0 to 16 minutes of low heat depending on the length of the previous thermostat cycle Airflow control is accomplished by using a technique involving the microprocessor and blower motor The static load on the...

Page 3: ...ed polypropylene laminated steel to ensure durability 8 Pressure switches ensure adequate flow of flue products through furnace and out vent system 9 Inducer motor Pulls hot flue gases through the heat exchangers maintaining negative pressure for added safety 10 Condensate drain connection Collects moisture condensed during combustion process 11 Heavy duty blower Circulates air across the heat exc...

Page 4: ...ronic Air Cleaner Model EACA X X X X X Mechanical Air Cleaner Model FILCAB or EZXCAB X X X X X Humidifier Model HUM X X X X X Heat Recovery Ventilator Model HRV X X X X X Energy Recovery Ventilator Model ERV X X X X X UV Lights Model UVL X X X X X EZ Flex Media Filter with end caps 16 in 9 pack EXPXXLMC0016 X EZ Flex Media Filter with end caps 20 in 9 pack EXPXXLMC0020 X X X EZ Flex Media Filter w...

Page 5: ...20 X X X Gas Orifice Kit Size 42 Qty 50 KGAHA0150N42 See Installation Instructions for model altitude and heat value usages Gas Orifice Kit Size 43 Qty 50 KGAHA0250N43 Gas Orifice Kit Size 44 Qty 50 KGAHA0350N44 Gas Orifice Kit Size 45 Qty 50 KGAHA0450N45 Gas Orifice Kit Size 46 Qty 50 KGAHA0550N46 Gas Orifice Kit Size 47 Qty 50 KGAHA1550N47 Gas Orifice Kit Size 48 Qty 50 KGAHA850N48 Gas Orifice K...

Page 6: ...itioner _F _C Auto Changeover 7 Day Programmable TSTATCCSAC01 For use with 1 speed Air Conditioner _F _C Auto Changeover 5 2 Programmable TSTATCCPDF01 B For use with multi stage applications _F _C Auto Changeover 7 Day Programmable TSTATCCPRH01 B For multi use stage configurations _F _C Auto Changeover 7 Day Programmable SYSTXCCUID01 A For multi use stage configurations _F _C Auto Changeover 7 Day...

Page 7: ...Ð LOW VOLTAGE MAIN HARNESS CONNECTOR EAC 1 TERMINAL 115 VAC 1 0 AMP MAX 115 VAC L1 LINE VOLTAGE CONNECTIONS 115 VAC L2 NEUTRAL CONNECTIONS PL2 Ð HOT SURFACE IGNITER INDUCER MOTOR CONNECTOR 24 V THERMOSTAT TERMINALS FUTURE APPLICATIONS X A92505 Heat Exchangers A02278 Control Center A02286 Inducer Assembly A93086 Concentric Vent Direct Vent 2 Pipe Only A concentric vent kit allows vent and combustio...

Page 8: ...2 Controls Thermostats and Zoning Available in programmable and non programmable models Carrier thermostats maintain a constant comfortable temperature level in the home For the ultimate in home comfort Carrier s 2 4 or 8 zone systems allow temperature control of individual zones of the home This is accomplished through a series of electronic dampers and remote room sensors The 4 zone system is sh...

Page 9: ...IZE 060 14 080 14 080 20 100 20 120 20 Direct Drive Motor Hp ECM 1 2 1 2 1 1 1 Motor Full Load Amps 7 7 7 7 12 8 12 8 12 8 RPM Nominal Speeds Variable 250 1300 Blower Wheel Diameter X Width in 10 X 7 11 X 10 11 X 10 11 X 10 11 X 10 Filter Size in Nominal A Washable 1 16 X 25 X 1 1 20 X 25 X 1 1 20 X 25 X 1 1 20 X 25 X 1 1 24 X 25 X 1 Shipping Weight lb 170 182 204 203 234 Limit Control SPST Heatin...

Page 10: ...00 75 000 75 000 94 000 113 000 AFUE 95 0 95 0 95 0 95 0 95 0 Input Btuh Low 39 000 52 000 52 000 65 000 78 000 High 60 000 80 000 80 000 100 000 120 000 Airflow shown is for bottom only return air supply with factory supplied 1 in washable filter s For air delivery above 1800 CFM see Air Delivery table for other options Low heat CFM when low heat rise adjustment switch SW1 3 on furnace control is...

Page 11: ...0 1250 1200 1155 1 1 2 Ton A C Cooling 525 0 0 50 525 525 515 505 485 2 Ton A C Cooling 700 0 0 50 700 700 695 695 700 2 1 2 Ton A C Cooling 875 0 1 0 840 855 875 875 875 875 870 855 850 850 3 Ton A C Cooling 1050 0 1 0 1050 1050 1050 1050 1050 1050 1045 1045 1040 1030 3 1 2 Ton A C Cooling 1225 0 1 0 1225 1225 1225 1225 1225 1225 1225 1225 1225 1195 Maximum 1400 0 1 0 1400 1400 1400 1400 1395 135...

Page 12: ... 50 700 700 700 700 695 2 1 2 Ton A C Cooling 875 0 0 50 875 875 875 870 870 3 Ton A C Cooling 1050 0 1 0 1035 1040 1050 1050 1050 1050 1050 1025 1005 1000 3 1 2 Ton A C Cooling 1225 0 1 0 1205 1210 1225 1225 1225 1225 1225 1225 1220 1215 4 Ton A C Cooling 1400 0 1 0 1390 1400 1400 1400 1400 1400 1395 1385 1370 1360 5 Ton A C Cooling 1750 0 1 0 1745 1740 1745 1745 1745 1745 1745 1740 1730 1715 6 T...

Page 13: ...6 5 8 6 1 4 5 3 4 KGAVT0601CVT 38 7 8 3 4 1 2 21 1 8 7 3 8 6 1 2 Dimension A will change proportionally as dimension D is lengthened or shortened Dimension D may be lengthened to 60 in maximum Dimension D may also be shortened by cutting the pipes provided in the kit to 12 in minimum CONDENSATE TRAP CONDENSATE TRAP INSIDE BLOWER SHELF ALTERNATE DRAIN TUBE LOCATION UPFLOW APPLICATIONS CONDENSATE TR...

Page 14: ...uct is used see flex duct manufacturer s recommendations for equivalent diameters 2 Minimum return air opening at furnace a For 800 CFM 16 in round or 14 1 2 x 12 in rectangle b For 1200 CFM 20 in round or 14 1 2 x 19 1 2 in rectangle c For 1600 CFM 22 in round or 14 1 2 x 23 1 4 in rectangle d For airflow requirements above 1800 CFM see Air Delivery table in Product Data literature for specific u...

Page 15: ...0 Unit Volts Hertz Phase 115 60 1 Operating Voltage Range Min Max 104 127 Maximum Unit Amps 8 9 8 9 13 8 13 8 13 8 Minimum Wire Size 14 14 12 12 12 Maxium Wire Length ft 31 31 32 32 32 Maximum Fuse or Ckt Brk Amps 15 15 20 20 20 Transformer 24v 40va External Control Power Available Heating 25va Cooling 34va Permissible limits of the voltage range at which the unit will operate satisfactorily Lengt...

Page 16: ...CE COM R W C Y R G GND GND FIELD 24 VOLT WIRING FIELD 115 208 230 460 VOLT WIRING FACTORY 24 VOLT WIRING FACTORY 115 VOLT WIRING Connect Y Y2 terminal as shown for proper operation Some thermostats require a C terminal connection as shown If any of the original wire as supplied must be replaced use same type or equivalent wire 208 230 OR 460 VOLT THREE PHASE 208 230 VOLT SINGLE PHASE WHT BLK WHT B...

Page 17: ...TION TYPE PIPE DIA IN NUMBER OF 90_ ELBOWS 1 2 3 4 5 6 3001 to 4000 60 000 2 Pipe or 2 in Concentric 1 1 2 42 37 32 27 22 17 2 70 70 70 70 70 70 80 000 2 Pipe or 2 in Concentric 1 1 2 25 20 15 10 5 N A 2 70 70 70 70 70 70 100 000 2 Pipe or 2 in Concentric 2 38 33 28 23 18 13 2 1 2 70 70 70 70 70 70 120 000 2 Pipe or 3 in Concentric 3 one disk 29 24 10 N A N A N A 3 one disk 59 59 58 57 57 56 ALTIT...

Page 18: ...1 2 62 60 58 56 55 53 120 000 2 Pipe or 3 in Concentric 3 one disk 43 41 39 37 35 34 ALTITUDE UNIT SIZE BTUH TERMINATION TYPE PIPE DIA IN NUMBER OF 90_ ELBOWS 1 2 3 4 5 6 9001 to 10000 60 000 2 Pipe or 2 in Concentric 1 1 2 27 22 17 12 7 N A 2 57 55 53 51 49 47 80 000 2 Pipe or 2 in Concentric 1 1 2 15 10 5 N A N A N A 2 57 55 53 51 46 41 100 000 2 Pipe or 2 in Concentric 2 24 19 14 9 N A N A 2 1 ...

Page 19: ... 70 70 70 0 2 20 39 45 55 63 20 2 11 27 31 39 45 100 20 20 2 1 2 41 70 70 70 70 0 2 1 2 21 42 48 59 68 20 2 1 2 11 28 33 41 49 120 20 20 3 49 70 70 70 70 0 3 26 51 58 70 70 20 3 15 35 40 50 59 Pipe length ft specified for maximum vent pipe lengths located in unconditioned spaces Vent pipes located in unconditioned space cannot exceed the total allowable pipe length as specified in the Maximum Allo...

Page 20: ...cted on site This furnace may be installed in a manufactured mobile home when stated on rating plate and using factory authorized kit This furnace may be installed on combustible flooring in alcove or closet at Minimum Inches Clearance To Combustible Construction as described below This furnace requires a special venting system Refer to the installation instructions for parts list and method of in...

Page 21: ...21 TYPICAL INSTALLATIONS COMBUSTION AIR PIPE A C COIL OUTDOOR UNIT VENT PIPE HUMIDIFIER GAS FIRED WATER HEATER ELECTRONIC AIR CLEANER AIRFLOW FRONT OF FURNACE A06511 58UVB ...

Page 22: ...educe vibration transmission Primary Heat Exchangers Primary heat exchangers shall be 3 Pass 20 gauge corrosion resistant aluminized steel of fold and crimp sectional design and applied operating under negative pressure Secondary Heat Exchangers Secondary heat exchangers shall be of a flow through design having a patented interior laminate coating of polypropylene for greater corrosion resistance ...

Reviews: