GUIDE SPECIFICATIONS

General

System Description

Furnish a ______________________ (upflow) gas--fired

condensing furnace for use with natural gas or propane (factory--
authorized conversion kit required for propane); furnish cold air

return plenum; furnish external media cabinet for use with

accessory media filter or standard filter.

Quality Assurance

Unit will be designed, tested and constructed to the current ANSI

Z 21.47/CSA 2.3 design standard for gas--fired central furnaces.
Unit will be third party certified by CSA to the current ANSI Z
21.47/CSA 2.3 design standard for gas--fired central furnaces.

Unit will carry the CSA Blue Star

R

and Blue Flame

R

labels.

Unit efficiency testing will be performed per the current DOE test

procedure as listed in the Federal Register.
Unit will be certified for capacity and efficiency and listed in the
latest GAMA Consumer’s Directory of Certified Efficiency

Ratings.
Unit will carry the current Federal Trade Commission Energy

Guide efficiency label.

Delivery, Storage, and Handling

Unit will be shipped as single package only and is stored and
handled per unit manufacturer’s recommendations.

Warranty (for inclusion by specifying engineer)

U.S. and Canada only. Warranty certificate available upon

request.

Equipment

Blower Wheel and ECM Blower Motor
Galvanized blower wheel shall be centrifugal type, statically and

dynamically balanced. Blower motor of ECM type shall be

permanently lubricated with sealed ball bearings, of _______hp,
and have infinitely variable speed from 300--1300 RPM

operating only when 24--VAC motor inputs are provided. Blower
motor shall be direct drive and soft mounted to the blower scroll

to reduce vibration transmission.
Filters
Furnace shall have reusable--type filters. Filter shall be ______ in.

(X) ________ in. An accessory highly efficient Media Filter is
available as an option. _____________ Media Filter.
Casing
Casing shall be of .030 in. thickness minimum, pre--painted
galvanized steel.

Infinity 96

Two--Stage/Variable Speed Gas Furnace

58UVB

ECM Inducer Motor
ECM Inducer motor shall be variable speed design, soft mounted

to assembly to reduce vibration transmission.
Primary Heat Exchangers
Primary heat exchangers shall be 3--Pass 20 gauge corrosion--
resistant aluminized steel of fold--and--crimp sectional design and

applied operating under negative pressure.
Secondary Heat Exchangers
Secondary heat exchangers shall be of a flow--through design

having a patented interior laminate coating of polypropylene for
greater corrosion resistance with fold--and--crimp design and

applied operating under negative pressure.
Controls
Controls shall include a micro--processor--based integrated

electronic control board with at least 16 service troubleshooting
codes displayed via diagnostic flashing LED light on the control,

a self--test feature that checks all major functions of the furnace,
and a replaceable automotive--type circuit protection fuse.

Multiple operational settings available, including separate blower

speeds for low heat, high heat, low cooling, high cooling and
continuous fan. Continuous fan speed may be adjusted from the

thermostat. Cooling airflow will be selectable between 350 or 400
CFM per ton of air conditioning. Features will also include

temporary reduced airflow in the cooling mode for improved

dehumidification when an Infinity Control or Thermidistat is
selected as the thermostat.

Operating Characteristics

Heating capacity shall be _________________ Btuh input;
______________ Btuh output capacity.
Fuel Gas Efficiency shall be 95% AFUE.
Air delivery shall be ________________ cfm minimum at 0.50
in. wc. external static pressure.
Dimensions shall be: depth_________in.; width __________in.;
height___________in. (casing only). Height shall be

_________in. with A/C coil and _________________in. overall

with plenum.

Electrical Requirements

Electrical supply shall be 115 volts, 60 Hz, single--phase

(nominal). Minimum wire size shall be ________AWG;
maximum fuse size of HACR--type designated circuit breaker

shall be _________ amps.

Special Features

Refer to section of the product data identifying accessories and
descriptions for specific features and available enhancements.

Copyright 2006 Carrier Corp.

S

7310 W. Morris St.

S

Indianapolis, IN 46231

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

Catalog No:58UVB---1PD

Replaces:NEW

Printed in U.S.A.

Edition date: 09/06

58U

VB

Summary of Contents for Infinity 96 58UVB

Page 1: ... pipe only The Infinity 96 is not approved for installation in mobile homes recreational vehicles or outdoor use The variable speed makes the Infinity 96 ideal for use with split system cooling including 2 stage units A Carrier electronic air cleaner humidifier Thermidistatt comfort ventilator and Comfort Zonet II will provide year round comfort and efficiency Designed for durability comfort and r...

Page 2: ... The first cycle after power reset provides 16 minutes of low heat before switching to high heat unless the room thermostat has been satisfied Subsequent thermostat cycles provide anywhere from 0 to 16 minutes of low heat depending on the length of the previous thermostat cycle Airflow control is accomplished by using a technique involving the microprocessor and blower motor The static load on the...

Page 3: ...ed polypropylene laminated steel to ensure durability 8 Pressure switches ensure adequate flow of flue products through furnace and out vent system 9 Inducer motor Pulls hot flue gases through the heat exchangers maintaining negative pressure for added safety 10 Condensate drain connection Collects moisture condensed during combustion process 11 Heavy duty blower Circulates air across the heat exc...

Page 4: ...ronic Air Cleaner Model EACA X X X X X Mechanical Air Cleaner Model FILCAB or EZXCAB X X X X X Humidifier Model HUM X X X X X Heat Recovery Ventilator Model HRV X X X X X Energy Recovery Ventilator Model ERV X X X X X UV Lights Model UVL X X X X X EZ Flex Media Filter with end caps 16 in 9 pack EXPXXLMC0016 X EZ Flex Media Filter with end caps 20 in 9 pack EXPXXLMC0020 X X X EZ Flex Media Filter w...

Page 5: ...20 X X X Gas Orifice Kit Size 42 Qty 50 KGAHA0150N42 See Installation Instructions for model altitude and heat value usages Gas Orifice Kit Size 43 Qty 50 KGAHA0250N43 Gas Orifice Kit Size 44 Qty 50 KGAHA0350N44 Gas Orifice Kit Size 45 Qty 50 KGAHA0450N45 Gas Orifice Kit Size 46 Qty 50 KGAHA0550N46 Gas Orifice Kit Size 47 Qty 50 KGAHA1550N47 Gas Orifice Kit Size 48 Qty 50 KGAHA850N48 Gas Orifice K...

Page 6: ...itioner _F _C Auto Changeover 7 Day Programmable TSTATCCSAC01 For use with 1 speed Air Conditioner _F _C Auto Changeover 5 2 Programmable TSTATCCPDF01 B For use with multi stage applications _F _C Auto Changeover 7 Day Programmable TSTATCCPRH01 B For multi use stage configurations _F _C Auto Changeover 7 Day Programmable SYSTXCCUID01 A For multi use stage configurations _F _C Auto Changeover 7 Day...

Page 7: ...Ð LOW VOLTAGE MAIN HARNESS CONNECTOR EAC 1 TERMINAL 115 VAC 1 0 AMP MAX 115 VAC L1 LINE VOLTAGE CONNECTIONS 115 VAC L2 NEUTRAL CONNECTIONS PL2 Ð HOT SURFACE IGNITER INDUCER MOTOR CONNECTOR 24 V THERMOSTAT TERMINALS FUTURE APPLICATIONS X A92505 Heat Exchangers A02278 Control Center A02286 Inducer Assembly A93086 Concentric Vent Direct Vent 2 Pipe Only A concentric vent kit allows vent and combustio...

Page 8: ...2 Controls Thermostats and Zoning Available in programmable and non programmable models Carrier thermostats maintain a constant comfortable temperature level in the home For the ultimate in home comfort Carrier s 2 4 or 8 zone systems allow temperature control of individual zones of the home This is accomplished through a series of electronic dampers and remote room sensors The 4 zone system is sh...

Page 9: ...IZE 060 14 080 14 080 20 100 20 120 20 Direct Drive Motor Hp ECM 1 2 1 2 1 1 1 Motor Full Load Amps 7 7 7 7 12 8 12 8 12 8 RPM Nominal Speeds Variable 250 1300 Blower Wheel Diameter X Width in 10 X 7 11 X 10 11 X 10 11 X 10 11 X 10 Filter Size in Nominal A Washable 1 16 X 25 X 1 1 20 X 25 X 1 1 20 X 25 X 1 1 20 X 25 X 1 1 24 X 25 X 1 Shipping Weight lb 170 182 204 203 234 Limit Control SPST Heatin...

Page 10: ...00 75 000 75 000 94 000 113 000 AFUE 95 0 95 0 95 0 95 0 95 0 Input Btuh Low 39 000 52 000 52 000 65 000 78 000 High 60 000 80 000 80 000 100 000 120 000 Airflow shown is for bottom only return air supply with factory supplied 1 in washable filter s For air delivery above 1800 CFM see Air Delivery table for other options Low heat CFM when low heat rise adjustment switch SW1 3 on furnace control is...

Page 11: ...0 1250 1200 1155 1 1 2 Ton A C Cooling 525 0 0 50 525 525 515 505 485 2 Ton A C Cooling 700 0 0 50 700 700 695 695 700 2 1 2 Ton A C Cooling 875 0 1 0 840 855 875 875 875 875 870 855 850 850 3 Ton A C Cooling 1050 0 1 0 1050 1050 1050 1050 1050 1050 1045 1045 1040 1030 3 1 2 Ton A C Cooling 1225 0 1 0 1225 1225 1225 1225 1225 1225 1225 1225 1225 1195 Maximum 1400 0 1 0 1400 1400 1400 1400 1395 135...

Page 12: ... 50 700 700 700 700 695 2 1 2 Ton A C Cooling 875 0 0 50 875 875 875 870 870 3 Ton A C Cooling 1050 0 1 0 1035 1040 1050 1050 1050 1050 1050 1025 1005 1000 3 1 2 Ton A C Cooling 1225 0 1 0 1205 1210 1225 1225 1225 1225 1225 1225 1220 1215 4 Ton A C Cooling 1400 0 1 0 1390 1400 1400 1400 1400 1400 1395 1385 1370 1360 5 Ton A C Cooling 1750 0 1 0 1745 1740 1745 1745 1745 1745 1745 1740 1730 1715 6 T...

Page 13: ...6 5 8 6 1 4 5 3 4 KGAVT0601CVT 38 7 8 3 4 1 2 21 1 8 7 3 8 6 1 2 Dimension A will change proportionally as dimension D is lengthened or shortened Dimension D may be lengthened to 60 in maximum Dimension D may also be shortened by cutting the pipes provided in the kit to 12 in minimum CONDENSATE TRAP CONDENSATE TRAP INSIDE BLOWER SHELF ALTERNATE DRAIN TUBE LOCATION UPFLOW APPLICATIONS CONDENSATE TR...

Page 14: ...uct is used see flex duct manufacturer s recommendations for equivalent diameters 2 Minimum return air opening at furnace a For 800 CFM 16 in round or 14 1 2 x 12 in rectangle b For 1200 CFM 20 in round or 14 1 2 x 19 1 2 in rectangle c For 1600 CFM 22 in round or 14 1 2 x 23 1 4 in rectangle d For airflow requirements above 1800 CFM see Air Delivery table in Product Data literature for specific u...

Page 15: ...0 Unit Volts Hertz Phase 115 60 1 Operating Voltage Range Min Max 104 127 Maximum Unit Amps 8 9 8 9 13 8 13 8 13 8 Minimum Wire Size 14 14 12 12 12 Maxium Wire Length ft 31 31 32 32 32 Maximum Fuse or Ckt Brk Amps 15 15 20 20 20 Transformer 24v 40va External Control Power Available Heating 25va Cooling 34va Permissible limits of the voltage range at which the unit will operate satisfactorily Lengt...

Page 16: ...CE COM R W C Y R G GND GND FIELD 24 VOLT WIRING FIELD 115 208 230 460 VOLT WIRING FACTORY 24 VOLT WIRING FACTORY 115 VOLT WIRING Connect Y Y2 terminal as shown for proper operation Some thermostats require a C terminal connection as shown If any of the original wire as supplied must be replaced use same type or equivalent wire 208 230 OR 460 VOLT THREE PHASE 208 230 VOLT SINGLE PHASE WHT BLK WHT B...

Page 17: ...TION TYPE PIPE DIA IN NUMBER OF 90_ ELBOWS 1 2 3 4 5 6 3001 to 4000 60 000 2 Pipe or 2 in Concentric 1 1 2 42 37 32 27 22 17 2 70 70 70 70 70 70 80 000 2 Pipe or 2 in Concentric 1 1 2 25 20 15 10 5 N A 2 70 70 70 70 70 70 100 000 2 Pipe or 2 in Concentric 2 38 33 28 23 18 13 2 1 2 70 70 70 70 70 70 120 000 2 Pipe or 3 in Concentric 3 one disk 29 24 10 N A N A N A 3 one disk 59 59 58 57 57 56 ALTIT...

Page 18: ...1 2 62 60 58 56 55 53 120 000 2 Pipe or 3 in Concentric 3 one disk 43 41 39 37 35 34 ALTITUDE UNIT SIZE BTUH TERMINATION TYPE PIPE DIA IN NUMBER OF 90_ ELBOWS 1 2 3 4 5 6 9001 to 10000 60 000 2 Pipe or 2 in Concentric 1 1 2 27 22 17 12 7 N A 2 57 55 53 51 49 47 80 000 2 Pipe or 2 in Concentric 1 1 2 15 10 5 N A N A N A 2 57 55 53 51 46 41 100 000 2 Pipe or 2 in Concentric 2 24 19 14 9 N A N A 2 1 ...

Page 19: ... 70 70 70 0 2 20 39 45 55 63 20 2 11 27 31 39 45 100 20 20 2 1 2 41 70 70 70 70 0 2 1 2 21 42 48 59 68 20 2 1 2 11 28 33 41 49 120 20 20 3 49 70 70 70 70 0 3 26 51 58 70 70 20 3 15 35 40 50 59 Pipe length ft specified for maximum vent pipe lengths located in unconditioned spaces Vent pipes located in unconditioned space cannot exceed the total allowable pipe length as specified in the Maximum Allo...

Page 20: ...cted on site This furnace may be installed in a manufactured mobile home when stated on rating plate and using factory authorized kit This furnace may be installed on combustible flooring in alcove or closet at Minimum Inches Clearance To Combustible Construction as described below This furnace requires a special venting system Refer to the installation instructions for parts list and method of in...

Page 21: ...21 TYPICAL INSTALLATIONS COMBUSTION AIR PIPE A C COIL OUTDOOR UNIT VENT PIPE HUMIDIFIER GAS FIRED WATER HEATER ELECTRONIC AIR CLEANER AIRFLOW FRONT OF FURNACE A06511 58UVB ...

Page 22: ...educe vibration transmission Primary Heat Exchangers Primary heat exchangers shall be 3 Pass 20 gauge corrosion resistant aluminized steel of fold and crimp sectional design and applied operating under negative pressure Secondary Heat Exchangers Secondary heat exchangers shall be of a flow through design having a patented interior laminate coating of polypropylene for greater corrosion resistance ...

Reviews: