APPLICATION CONSIDERATIONS

The Infinity

t

Air Purifier is designed for use in the return air

duct of a forced air heating, cooling, and ventilation system.

Models GAPAAXCC1625 and GAPAAXCC2025 are

specifically designed for use in systems with a forced air gas

furnace.

Air Conditioning

The Infinity

t

Air Purifier should be installed in a system so

that all the return air is circulated through the air purifier. It

should be located upstream of both the furnace and the air

conditioning evaporator coil. This will help keep the furnace

and evaporator coil clean and prevent condensation from

forming within the Infinity

t

Air Purifier.

Humidifiers

An evaporative humidifier can be mounted upstream of the

Infinity

t

Air Purifier. It is best to install atomizing humidifiers

downstream of the air purifier because hard water salt deposits

and water droplets may damage air purifier. If an atomizing

humidifier must be mounted upstream of the Infinity

t

Air

Purifier, it should be mounted as far upstream as possible (at

least 6 ft recommended), and a standard disposable furnace

filter should be mounted between the humidifier and the air

purifier to trap hard water salt deposits and water droplets.

Transitions

If the return air duct or furnace openings do not fit the Infinity

t

Air Purifier cabinet openings, gradual transitions are

recommended to reduce air turbulence and maximize efficiency.

No more than 20 degrees (about 4 in. per running ft) of

expansion should be used on each side of the transition fitting.

Turning Vanes

If the Infinity

t

Air Purifier is installed adjacent to a 90 degree

duct elbow, turning vanes should be added inside duct to

improve air distribution across the face of the air purifier.

Electrical Power

The Infinity

t

Air Purifier should only be powered when

airflow is present. The furnace control EAC terminals provide

power only when the furnace blower is operating. Infinity

t

Air

Purifier models GAPAAXCC1625 and GAPAAXCC2025 are

designed to be powered from the electronic air cleaner (EAC)

terminals on a furnace electronic control. If EAC terminals are

not available, an alternative airflow sensing mechanism must be

used to ensure the Infinity

t

Air Purifier is only powered when

airflow is present. Contact local Carrier distributor for

information on approved alternatives.

Door (x1)

Cabinet (x1)

Enhancement Module (x1)

Safety Screen (x1)

Installation Manual

Duct Gasket Tape

(1 roll)

Furnace Adapters (x2)

Return Duct Adapters:
Long (x2) / Short (x2)

Air Purification Cartridge (x1)

(x2)

(x2)

(x1)

(x1)

(x2)

Installation Components

(in bag attached to power cord)

A06027

Fig. 2 -- Infinity

t

Air Purifier Components

GAP

A

Summary of Contents for INFINITY 1625

Page 1: ...ee captured particles are killed by electrical current flow and ion bombardment A05265 Fig 1 GAPA Unit SAFETY CONSIDERATIONS Improper installation adjustment alteration service maintenance or use can cause explosion fire electrical shock or other conditions which may cause personal injury or property damage Consult a qualified installer service agency or your distributor or branch for information ...

Page 2: ... If the return air duct or furnace openings do not fit the Infinityt Air Purifier cabinet openings gradual transitions are recommended to reduce air turbulence and maximize efficiency No more than 20 degrees about 4 in per running ft of expansion should be used on each side of the transition fitting Turning Vanes If the Infinityt Air Purifier is installed adjacent to a 90 degree duct elbow turning...

Page 3: ... of the Infinityt Air Purifier should be readily accessible Enough room should be provided for periodic replacement of the air purifier cartridges ELECTRICAL SHOCK AND UNIT DAMAGE HAZARD Failure to follow this warning could result in personal injury or death Only a trained experienced service person should install the Infinityt Air Purifier A thorough check of the unit installation should be compl...

Page 4: ...net between the furnace and return air duct see Fig 3 and 4 A transition duct may be required e Furnace adapters have been included for installer convenience They are designed for top or bottom mount installations see Fig 5 f Return air duct adapters have been included for installer convenience They should be used to connect the upstream side of the air purifier cabinet to the return air duct see ...

Page 5: ...ly connector see Fig 7 d Route the power cord through nearest cabinet hole and protect with enclosed cable connector Zip ties have been enclosed to secure the power cord to the side of the power supply e Attach the quick connect terminals to the furnace EAC 1 and EAC 2 spade connections Attach the ground ring to furnace chassis ground NOTE The Infinityt Air Purifier is to be powered by 115v 60 Hz ...

Page 6: ... system fan c Turn the Infinityt Air Purifier power switch to on position d The power indicator light above the Air Purifier power switch should illuminiate see Fig 8 e Check to ensure the light goes off when the Infinityt Air Purifier power switch is set to off when the blower goes off or when the HVAC system power is turned off Step 2 Infinity Control a When the Infinityt Air Purifier is used wi...

Page 7: ...er indicator light located on the door see Fig 8 This power indicator light will illuminate when the Infinityt Air Purifier door is installed the power switch is in the on position AND the furnace blower is running If the power indicator light is not illuminated follow the troubleshooting steps below Step 1 Check that the Infinityt Air Purifier door is installed NOTE Amagnet inthe door see Fig 9 i...

Page 8: ...nace EAC terminals 115v 60 Hz from furnace EAC terminals Maximum Airflow CFM 1600 2000 Efficiency Equivalent to MERV 15 Equivalent to MERV 15 Replacement Cartridge GAPCCCAR1625 GAPCCCAR2025 Dimensions GAPAAXCC1625 GAPAAXCC2025 A 18 3 8 21 7 8 B 15 1 8 18 5 8 C 11 1 8 11 1 8 D 17 1 2 21 E 22 1 8 22 1 8 F 25 1 4 25 1 4 7 16 Typical Top Bottom 1 3 16 1 3 16 1 3 16 1 15 16 A C E F B D A05270 Fig 10 Di...

Page 9: ...urned to the distributor through a registered servicing dealer for credit 4 All work shall be performed during normal working hours LIMITATIONS OF WARRANTIES ALL IMPLIED WARRANTIES INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY LIMITED IN DURATION TO THE PERIOD FOR WHICH THE LIMITED WARRANTY IS GIVEN AND APPLIES SOME STATES DO NOT ALLOW LIMITATIONS ...

Page 10: ...10 W Morris St S Indianapolis IN 46231 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Catalog No GAPA 2SI Replaces GAPA 1SI Printed in China Edition Date 3 06 GAPA ...

Reviews: