background image

10

Copyright 2005 Carrier Corp.

S

7310 W. Morris St.

S

Indianapolis, IN 46231

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

Catalog No: GAPA---2SI

Replaces: GAPA---1SI

Printed in China

Edition Date: 3/06

GAP

A

Summary of Contents for INFINITY 1625

Page 1: ...ee captured particles are killed by electrical current flow and ion bombardment A05265 Fig 1 GAPA Unit SAFETY CONSIDERATIONS Improper installation adjustment alteration service maintenance or use can cause explosion fire electrical shock or other conditions which may cause personal injury or property damage Consult a qualified installer service agency or your distributor or branch for information ...

Page 2: ... If the return air duct or furnace openings do not fit the Infinityt Air Purifier cabinet openings gradual transitions are recommended to reduce air turbulence and maximize efficiency No more than 20 degrees about 4 in per running ft of expansion should be used on each side of the transition fitting Turning Vanes If the Infinityt Air Purifier is installed adjacent to a 90 degree duct elbow turning...

Page 3: ... of the Infinityt Air Purifier should be readily accessible Enough room should be provided for periodic replacement of the air purifier cartridges ELECTRICAL SHOCK AND UNIT DAMAGE HAZARD Failure to follow this warning could result in personal injury or death Only a trained experienced service person should install the Infinityt Air Purifier A thorough check of the unit installation should be compl...

Page 4: ...net between the furnace and return air duct see Fig 3 and 4 A transition duct may be required e Furnace adapters have been included for installer convenience They are designed for top or bottom mount installations see Fig 5 f Return air duct adapters have been included for installer convenience They should be used to connect the upstream side of the air purifier cabinet to the return air duct see ...

Page 5: ...ly connector see Fig 7 d Route the power cord through nearest cabinet hole and protect with enclosed cable connector Zip ties have been enclosed to secure the power cord to the side of the power supply e Attach the quick connect terminals to the furnace EAC 1 and EAC 2 spade connections Attach the ground ring to furnace chassis ground NOTE The Infinityt Air Purifier is to be powered by 115v 60 Hz ...

Page 6: ... system fan c Turn the Infinityt Air Purifier power switch to on position d The power indicator light above the Air Purifier power switch should illuminiate see Fig 8 e Check to ensure the light goes off when the Infinityt Air Purifier power switch is set to off when the blower goes off or when the HVAC system power is turned off Step 2 Infinity Control a When the Infinityt Air Purifier is used wi...

Page 7: ...er indicator light located on the door see Fig 8 This power indicator light will illuminate when the Infinityt Air Purifier door is installed the power switch is in the on position AND the furnace blower is running If the power indicator light is not illuminated follow the troubleshooting steps below Step 1 Check that the Infinityt Air Purifier door is installed NOTE Amagnet inthe door see Fig 9 i...

Page 8: ...nace EAC terminals 115v 60 Hz from furnace EAC terminals Maximum Airflow CFM 1600 2000 Efficiency Equivalent to MERV 15 Equivalent to MERV 15 Replacement Cartridge GAPCCCAR1625 GAPCCCAR2025 Dimensions GAPAAXCC1625 GAPAAXCC2025 A 18 3 8 21 7 8 B 15 1 8 18 5 8 C 11 1 8 11 1 8 D 17 1 2 21 E 22 1 8 22 1 8 F 25 1 4 25 1 4 7 16 Typical Top Bottom 1 3 16 1 3 16 1 3 16 1 15 16 A C E F B D A05270 Fig 10 Di...

Page 9: ...urned to the distributor through a registered servicing dealer for credit 4 All work shall be performed during normal working hours LIMITATIONS OF WARRANTIES ALL IMPLIED WARRANTIES INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY LIMITED IN DURATION TO THE PERIOD FOR WHICH THE LIMITED WARRANTY IS GIVEN AND APPLIES SOME STATES DO NOT ALLOW LIMITATIONS ...

Page 10: ...10 W Morris St S Indianapolis IN 46231 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Catalog No GAPA 2SI Replaces GAPA 1SI Printed in China Edition Date 3 06 GAPA ...

Reviews: