7

START--UP AND OPERATION

Step 1

Checking Air Purifier Operation

ELECTRICAL SHOCK AND HIGH VOLTAGE

HAZARD

Failure to follow this warning could result in personal injury

or death.
Before installing or servicing system, always turn off main

power to system. There may be more than one (1) disconnect

switch.

!

WARNING

a. Attach the Infinity

t

Air Purifier door to the cabinet. A

magnet in the door (see Fig. 8) is used to activate a safety

switch in the power supply when the door is installed. The

power supply will not energize the air purifier unless the

safety switch is activated.

b. Turn the HVAC system power on and adjust the thermo-

stat or Infinity

t

System Control to activate the system

fan.

c. Turn the Infinity

t

Air Purifier power switch to on posi-

tion.

d. The power indicator light above the Air Purifier power

switch should illuminate (see Fig. 13).

e. Check to ensure the light goes off when the Infinity

t

Air

Purifier power switch is set to off, when the blower goes

off, or when the HVAC system power is turned off.

NOTE

:

Upon power--up, the light will come on for

approximately 5 seconds and if no flow is detected, it will go off.

If no air purifier cartridge is detected, the flow sensor will detect

this and turn off after approximately 7 seconds.

Step 2

Infinity Control

a. When the Infinity

t

Air Purifier is used with an Infinity

Control, the Infinity Control can be configured to remind

the homeowner when it is time to change the Infinity

t

Air Purifier cartridge. This maintenance reminder can be

based on either the TrueSense

t

dirty filter algorithm or

time. The installer should use their discretion to select the

most appropriate option based on the initial system static

pressure.

Step 3

Maximizing Performance

a. Maximum air purification performance is obtained when

the furnace blower is set for continuous operation on the

thermostat or Infinity Control.

Door Switch Magnet

A06379

Fig. 12

---

Door Switch Magnet

Power Indicator

A06380

Fig. 13

---

Power Indicator

MAINTENANCE

The Infinity

t

Air Purifier is designed to require minimal

maintenance. Maintenance is limited to the replacement of the

air purification cartridge and inspection/brush cleaning of the

ionization array. Frequency of air purifier cartridge replacement

and cleaning of the ionization array may vary depending on

ductwork design and local environmental conditions.

To replace the air purifier cartridge, complete the following
steps:
Step 1

Turn the heating and cooling system power

off.

ELECTRICAL SHOCK AND HIGH VOLTAGE

HAZARD

Failure to follow this warning could result in personal injury

or death.
Before installing or servicing system, always turn off main

power to system. There may be more than one (1) disconnect

switch.

!

WARNING

Step 2

Turn the Infinity

t

Air Purifier switch to the off

position.

Step 3

Remove the Infinity

t

Air Purifier door.

Step 4

Slide out the old air purifier cartridge and discard.

Step 5

Install the new air purifier cartridge.

NOTE

: Make sure that the arrows on the air purifier cartridge

point toward the fan coil. This should be in the same
direction as airflow.

Step 6

Replace the Infinity

t

Air Purifier door.

Step 7

Turn the Infinity

t

Air Purifier switch to the on

position.

Step 8

Turn heating and cooling system power on.

GAP

A

B

Summary of Contents for INFINITY 1620

Page 1: ...ified for shock and electrical fire hazard only La Infinityt Air Purifier certification CSA vise uniquement les risques de choc electrique et A06377 Fig 1 GAPAB Unit SAFETY CONSIDERATIONS Improper installation adjustment alteration service maintenance or use can cause explosion fire electrical shock or other conditions which may cause personal injury or property damage Consult a qualified installe...

Page 2: ...1 x1 x2 x3 x1 x2 Installation Components in bag attached to power cord Installation Manual 1 GAPA Infinity Air Purifier Sizes 1620 2020 2420 Installation Start up and Operating Instructions NOTE Readth eentireinstruct ion manual befores tartingth e install TABLE OF CONTE NTS Pa ge SAFETY CONSID ERA TIONS 1 INTROD UCTION 2 PLANN ING 2 5 Applica tion 2 Ins tallation Require ments 2 Dimens ions Table...

Page 3: ...urifier or door can be rotated 180_ to accommodate the cabinet orientation c The location of the Infinityt Air Purifier should be readi ly accessible Enough room should be provided for peri odic replacement of the air purifier cartridges ELECTRICAL SHOCK AND UNIT DAMAGE HAZARD Failure to follow this warning could result in personal injury or death Only a trained experienced service person should i...

Page 4: ... work See Fig 6 h Seal seams with tape or caulking after the Infinityt Air Purifier cabinet has been secured ELECTRICAL SHOCK AND HIGH VOLTAGE HAZARD Failure to follow this warning could result in personal injury or death Before installing or servicing system always turn off main power to system There may be more than 1 disconnect switch WARNING UNIT DAMAGE HAZARD Failure to follow this caution ma...

Page 5: ...g With the bypass jumper in place the air purifier will be on at all times when connected to electrical line power see Fig 10 d Attach the quick connect terminals to the fused power connector leads in parts bag attached to power cord and connect to incoming field power Attach the ground ring to fan coil chassis ground See Fig 10 ELECTRICAL SHOCK AND HIGH VOLTAGE HAZARD Failure to follow this warni...

Page 6: ...POWER CONNECTION TO L2 FIELD POWER SUPPLY TO L1 FIELD POWER SUPPLY 5 AMP IN LINE FUSES GROUND ATTACH TO FAN COIL GROUND CHASSIS CABLE CONNECTOR TO SECURE POWER CORD TO FAN COIL CABINET A06515 Fig 10 Fan Coil Chassis Ground Air Flow Sensor 1 Slide flow sensor tabs into support bracket 2 Rotate flow sensor and clip into bracket A06412 Fig 11 Flow Sensor Install GAPAB ...

Page 7: ...r the TrueSenset dirty filter algorithm or time The installer should use their discretion to select the most appropriate option based on the initial system static pressure Step 3 Maximizing Performance a Maximum air purification performance is obtained when the furnace blower is set for continuous operation on the thermostat or Infinity Control Door Switch Magnet A06379 Fig 12 Door Switch Magnet P...

Page 8: ...ate protective clothing and gloves when handling parts WARNING Step 6 Slide out the Safety Screen and set aside NOTE Best cleaning tools 5 inch handle paint brush with 2 inch width or greater brush point synthetic or natural bristle See Fig 14 or vacuum cleaner with brush attachment Step 7 Gently stroke the ionization pins on the top plane of each bar with enough brush depth to hit front and back ...

Page 9: ...tion Step 3 Confirm that the fan coil blower is operating Step 4 Confirm that 208 230 VAC power is provided Attach power supply connector to the air purifier when the fan coil blower is operating NOTE Even though power is supplied to the Infinityt Air Purifier it will not turn on unless the airflow sensor senses airflow or the airflow sensor s bypass plug is inserted Step 5 Confirm that the airflo...

Page 10: ...imum Airflow CFM 1350 1800 2000 Efficiency Equivalent to MERV 15 Equivalent to MERV 15 Equivalent to MERV 15 Replacement Cartridge GAPCCCAR1620 GAPCCCAR2020 GAPCCCAR2420 Initial Pressure Drop in w c at maximum airflow 22 25 22 Dimensions GAPABXCC1620 GAPABXCC2020 GAPABXCC2420 A 18 1 2 22 25 1 2 B 15 1 8 18 5 8 22 1 8 C 13 1 8 13 1 8 13 1 8 D 17 5 8 21 1 8 24 5 8 E 19 3 4 19 3 4 19 3 4 F 22 1 4 22 ...

Page 11: ...a registered servicing dealer for credit 4 All work shall be performed during normal working hours LIMITATIONS OF WARRANTIES ALL IMPLIED WARRANTIES AND OR CONDITIONS INCLUDING IMPLIED WARRANTIES OR CON DITIONS OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY LIMITED IN DURATION TO THE PERIOD FOR WHICH THE LIMITED WARRANTY OR CONDITION IS GIVEN AND APPLIES SOME STATES OR PROVINCES...

Page 12: ... W Morris St S Indianapolis IN 46231 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Catalog No GAPAB 2SI Replaces GAPAB 1SI Printed in U S A Edition Date 02 07 GAPAB ...

Reviews: